Yes, the Autofluorescence Eliminator Reagent has been known to effectively reduce autofluorescence signals from lipofuscin in human neural samples. For further reference, the following citation may be of interest:
Neuroscience. 2013 Jul 9;242:140-50. doi: 10.1016/j.neuroscience.2013.03.049. Epub 2013 Apr 2.
Prolyl oligopeptidase colocalizes with α-synuclein, β-amyloid, tau protein and astroglia in the post-mortem brain samples with Parkinson's and Alzheimer's diseases. PMID: 23562579
Seleccione un Tamaño
| Talla/SKU | Disponibilidad | Precio |
|---|---|---|
50 mL | Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad | 202,00 € |
Acerca de este artículo
202,00 €
form
liquid
packaging
pkg of 50 mL
manufacturer/tradename
Chemicon®
technique(s)
immunohistochemistry: suitable
shipped in
ambient
General description
Application
PROTOCOLO:
1.Después de histoquímica inmunofluorescente, los cortes se sumergen en PBS durante 5 min.·
2. Se sumergen en etanol al 70 % durante 5 minutos.·
3.Se sumergen en reactivo eliminador de la autofluorescencia durante 5 minutos.
4.Los cortes se sumergen en tres cambios de etanol al 70 % durante 1 minuto cada vez.·
5.Los cortes se montan utilizando una disolución que impida el cambio de color (DABCO, sin base de xileno).
Nota: el reactivo bloqueará toda la fluorescencia si la incubación es demasiado larga; el tiempo de incubación y el número de lavados con etanol al 70 % pueden alterarse y optimizarse para diversos tejidos y sondas de anticuerpos fluorescentes. En algunos casos, el reactivo se puede aplicar antes de la inmunofluorescencia. Sin embargo, en la mayoría de los casos se obtienen mejores resultados cuando se utiliza como se ha indicado antes (después de completar los procedimientos de inmunofluorescencia).
El usuario final debe determinar el tiempo óptimo de incubación con el reactivo eliminador de autofluorescencia para cada muestra.
Absorción máxima: 595-605
Physical form
Preparation Note
Legal Information
Disclaimer
1 of 1
Este artículo | ||
|---|---|---|
| description Autofluorescence Eliminator Reagent for IHC. | description The Human Mesenchymal Stem Cell Characterization Kit contains a panel of positive & negative selection markers for the characterization of the mesenchymal stem cell population in human samples. | description Sufficient for 200 tests |
| packaging pkg of 50 mL | packaging - | packaging - |
| technique(s) immunohistochemistry: suitable | technique(s) cell culture | stem cell: suitable, immunocytochemistry: suitable | technique(s) - |
| shipped in ambient | shipped in dry ice | shipped in dry ice |
| manufacturer/tradename Chemicon® | manufacturer/tradename Chemicon® | manufacturer/tradename - |
| form liquid | form - | form - |
Palabra de advertencia
Danger
Códigos de peligro
Indicaciones de precaución
Hazard Classifications
Eye Irrit. 2 - Flam. Liq. 2 - Muta. 2 - STOT SE 2
Órganos diana
Eyes,Central nervous system
Clase de almacenamiento
3 - Flammable liquids
WGK
WGK 2
Punto de inflamación (°F)
60.8 - 68.0 °F
Punto de inflamación (°C)
16 - 20 °C
Listados normativos
Los listados normativos se proporcionan para los productos químicos principalmente. Para los productos no químicos sólo se puede proporcionar información limitada. Si no hay ninguna entrada, significa que ninguno de los componentes está en la lista. Es obligación del usuario garantizar el uso seguro y legal del producto.
67-56-1
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
-
How can I eliminate autofluorescence signals of the human eye, specifically lipofuscin? Will the Autofluorescence Eliminator Reagent effectively work for this purpose?
1 respuesta-
¿Le ha resultado útil?
-