Likely not, due to pore size/possible fouling/chemical compatibility. Refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
Seleccione un Tamaño
| Talla/SKU | Disponibilidad | Precio |
|---|---|---|
12 ea | Fecha estimada de envío14 de septiembre de 2026desdeMerck Chemicals and LS SA | 268,00 € |
Acerca de este artículo
Quality Segment
material
polyethersulfone membrane, polystyrene bottle, polystyrene funnel(s), polystyrene housing
product line
Stericup®
feature
hydrophilic
packaging
pack of 12 ea
greener alternative product characteristics
Waste Prevention
Learn more about the Principles of Green Chemistry.
sustainability
Greener Alternative Product
parameter
max. temp. at 45 °C
description
2.4 mL (hold-up volume)
technique(s)
sterile filtration: suitable
H
188 mm
capacity
500 mL
diam.
9.3 cm
filter capacity
500 mL
filter diam.
73 mm
filtration area
40 cm2
matrix
Express PLUS™
pore size
0.22 μm pore size
fitting
inlet thread(s), 45 mm thread
greener alternative category
shipped in
ambient
storage temp.
no temp limit
General description
Para obtener más información, visite la BASE DE DATOS ACT
Los filtros esterilizantes Stericup® E y Steritop® E están diseñados como una Alternativa más Ecológica para la esterilización mediante filtración al vacío que reduce de manera significativa el plástico y los envases.
Este Stericup® E es un collarín de rosca de 45 mm que tiene una membrana de filtración de polietersulfona (PES) con un tamaño de poro de 0,22 μm combinada con un matraz receptor de 500 ml y una tapa para el procesamiento y almacenamiento. La rosca de 45 mm se conecta directamente a botellas de medios de cuello más ancho (como las botellas de vidrio o de Gibco®).
Use solo botellas de vidrio o plástico diseñadas para aplicaciones al vacío.
Application
- Medios de cultivo de tejidos +/- aditivos
- Amortiguadores
- Disoluciones biológicas
Features and Benefits
- El collar del filtro se desconecta de la botella receptora con solo un cuarto de vuelta—reduciendo así la probabilidad de derrame y haciendo que sea más fácil su manipulación sobre la mesa de trabajo o debajo de la campana.
- La identificación del producto en negrita en el collarín del filtro muestra claramente las características de la membrana, como su composición y el tamaño de los poros, para una selección de productos rápida y apropiada para la aplicación.
- El tapón de cierre mediante un clic está bridado y modificado para permitir un fuerte agarre en condiciones húmedas o secas—y un tope táctil confirma un cierre seguro. Preocúpese menos de la posibilidad de derramamiento o contaminación de los contenidos esterilizados.
- Una amplia superficie esmerilada de escritura en la botella receptora y el color más claro de la tapa facilita el etiquetado claro para mejorar la legibilidad y reducir los frotis ilegibles.
- La tapa descansa sobre el lateral para evitar el riesgo de contaminación.
- Las botellas receptoras son apilables para ahorrar espacio de almacenamiento.
Legal Information
1 of 1
Este artículo | |||
|---|---|---|---|
| description pore size 0.22 μm, polyethersulfone membrane, capacity 500 mL, 45 mm thread, pack of 12 ea | description pore size 0.22 μm, polyethersulfone membrane, filter capacity 1000 mL, 38 mm (1 1/2 in.) thread, pack of 12 ea | description pore size 0.22 μm, polyethersulfone membrane, filter capacity 150 mL × 1000 mL, 38 mm (1 1/2 in.) thread, pack of 12 ea, Greener Alternative | description pore size 0.22 μm, polyethersulfone membrane, filter capacity 150 mL × 1000 mL, 45 mm thread, pack of 12 ea |
| filter capacity 500 mL | filter capacity 1000 mL | filter capacity 150 mL , 150 mL × 1000 mL | filter capacity 150 mL , 150 mL × 1000 mL |
| pore size 0.22 μm pore size | pore size 0.22 μm pore size | pore size 0.22 μm pore size | pore size 0.22 μm pore size |
| material polyethersulfone membrane, polystyrene bottle, polystyrene housing, polystyrene funnel(s) | material polyethersulfone membrane, polystyrene bottle, polystyrene funnel(s), polystyrene housing | material polystyrene funnel(s), polystyrene housing, polystyrene bottle, polyethersulfone membrane | material polyethersulfone membrane, polystyrene bottle, polystyrene funnel(s), polystyrene housing |
| feature hydrophilic | feature hydrophilic | feature hydrophilic | feature hydrophilic |
| packaging pack of 12 ea | packaging pack of 12 ea | packaging pack of 12 ea | packaging pack of 12 ea |
| fitting inlet thread(s), 45 mm thread | fitting inlet thread(s), 38 mm (1 1/2 in.) thread | fitting 38 mm (1 1/2 in.) thread, inlet thread(s) | fitting 45 mm thread, inlet thread(s) |
Still not finding the right product?
Explore all of our products under Unidad de filtración Stericup® E-GP ecológica
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
-
Can we filter oil-type liquids with Stericup® filters?
Can we filter oil-type liquids with Stericup® filters?
1 respuesta-
¿Le ha resultado útil?
-
-
What leachables are detected during filtration processes using Stericup® filters?
1 respuesta-
We have not performed extractables/leachables studies for our Stericup® filters.
¿Le ha resultado útil?
-
-
What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?
1 respuesta-
All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
*Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.¿Le ha resultado útil?
-
-
What is the difference between classic Stericup® filters and Stericup® “Quick Release” filters?
1 respuesta-
Stericup® Quick Release, or “QR”, filters feature a connection between funnel filter and receiver bottle that requires only a quarter-turn release to facilitate funnel removal. These filters come fully engaged – there is no need to tighten before use. The receiver bottle cap has flanges on the top surface to improve grip, as well as a positive lock stop to ensure a leak-proof seal with the receiver bottle. Other improvements include a large, frosted writing surface on the receiver bottle and a lighter cap color to facilitate labelling, more prominent volume markings on the filtration funnel and receiver bottle, and a product label with a peel-off lot record strip on the bag for easy viewing in storage.
¿Le ha resultado útil?
-
-
What Bacterial Endotoxins Test is used?
1 respuesta-
The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.
¿Le ha resultado útil?
-
-
Can Stericup® and Steritop® filters be used to prepare solutions that will be administered to patients?
1 respuesta-
No, all Stericup® and Steritop® devices are Research Use Only.
¿Le ha resultado útil?
-
-
Which type of pump should be used with Stericup® and Steritop® vacuum filters?
Which type of pump should be used with Stericup® and Steritop® vacuum filters?
1 respuesta-
We recommend our Chemical Duty Pump: https://www.sigmaaldrich.com/product/mm/wp6111560
¿Le ha resultado útil?
-
-
Can Stericup® and Steritop® filters be reused?
1 respuesta-
All Stericup® and Steritop® filters were developed for single use, disposable processing.
¿Le ha resultado útil?
-
-
What tubing can be used with Stericup® and Steritop® vacuum filters?
What tubing can be used with Stericup® and Steritop® vacuum filters?
1 respuesta-
Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004
¿Le ha resultado útil?
-
-
What is the chemical compatibility of the various Stericup® and Steritop® filters?
What is the chemical compatibility of the various Stericup® and Steritop® filters?
1 respuesta-
Please refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
¿Le ha resultado útil?
-