This product has not been tested on microalgae.
Iniciar sesión para ver los precios por organización y contrato.
Seleccione un Tamaño
Cambiar Vistas
| Talla/SKU | Disponibilidad | Precio |
|---|---|---|
1 kit | Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad | 947,00 € |
Acerca de este artículo
NACRES:
NA.32
UNSPSC Code:
12352207
947,00 €
Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarleusage
sufficient for 200 tests
Quality Segment
packaging
pkg of 1 kit
technique(s)
flow cytometry: suitable
application(s)
cell analysis
detection
detection method
fluorometric
shipped in
wet ice
storage temp.
2-8°C
Biochem/physiol Actions
Sigma′s Annexin V-Cy3 kit allows detection of annexin V bound to apoptotic cells by fluorescence microscopy. The Annexin V-Cy3 kit uses the dye Cy3.18 as the fluorochrome conjugated with annexin V. By microscopy, Cy3.18 fluoresces more brightly than the FITC conjugate. The kit includes the non-fluorescent compound 6-carboxyfluorescein diacetate (6-CFDA), which enters the cell and is hydrolyzed by the esterases present in living cells to the fluorescent compound 6-carboxyfluorescein, indicating that the cells are viable. This combination allows the differentiation among early apoptotic cells (annexin V positive, 6-CFDA positive), necrotic cells (annexin V positive, 6-CFDA negative), and viable cells (annexin V negative, 6-CFDA positive).
Features and Benefits
Detects apoptosis earlier in the process than DNA-based assays such as TUNEL
- Rapid labeling of cells. Cell staining takes only 10 minutes.
- No cell fixation or processing required, reducing the detection time and allowing the cells to be used for further study.
- 6-Carboxyfluorescein diacetate secondary dye is included with the kit to differentiate apoptotic cells from viable and necrotic cells.
Legal Information
Cy3 is a trademark of Cytiva
1 of 1
Este artículo | |||
|---|---|---|---|
| description - | description - | description fluorometric assay kit for measuring Annexin V in apoptotic cells. | description - |
| technique(s) flow cytometry: suitable | technique(s) flow cytometry: suitable | technique(s) immunofluorescence: suitable, flow cytometry: suitable | technique(s) flow cytometry: suitable |
| storage temp. 2-8°C | storage temp. 2-8°C | storage temp. 2-8°C | storage temp. - |
| detection method fluorometric | detection method fluorometric | detection method fluorometric | detection method fluorometric |
| packaging pkg of 1 kit | packaging pkg of 1 kit | packaging pkg of 1 kit | packaging - |
| application(s) cell analysis | application(s) cell analysis | application(s) - | application(s) - |
| shipped in wet ice | shipped in wet ice | shipped in wet ice | shipped in - |
Clase de almacenamiento
10 - Combustible liquids
Punto de inflamación (°F)
Not applicable
Punto de inflamación (°C)
Not applicable
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
-
can we use this kit used for microalgae cells
1 respuesta-
¿Le ha resultado útil?
-