  • Occupational exposure to styrene in the fibreglass reinforced plastic industry: comparison between two different manufacturing processes.

Occupational exposure to styrene in the fibreglass reinforced plastic industry: comparison between two different manufacturing processes.

La Medicina del lavoro (2012-10-20)
Giovanna Tranfo, Monica Gherardi, E Paci, Mariapia Gatto, A Gordiani, Lidia Caporossi, Silvia Capanna, Renata Sisto, B Papaleo, Carla Fiumalbi, Patrizia Garofani
RESUMEN

Styrene is used in manufacturing fiberglass reinforced plastics: and occupational exposure was related to neurotoxicology and genotoxicity. The sum of the metabolites mandelic and phenylglyoxylic acids is the ACGIH biomarker for occupational exposure with a BEI of 400 mg/g of creatinine in end shift urine corresponding to a airborne styrene concentration of 85 mg/m3. There are two main molding processes, open and closed, the last more effective at controlling worker's styrene exposure. To compare the open molding process to the compression of fiber reinforced resin foils, a kind of closed molding, monitoring the styrene exposure of workers in two production sites (A and B). Environmental Monitoring was carried out by Radiello samplers and Biological Monitoring by means of the determination of MA and PGA with HPLC/MS/MS in 10 workers at Site A and 14 at Site B. The median values for styrene exposure resulted 31.1 mg/m3 for Site A and 24.4 mg/m for Site B, while the medians for the sum of the two metabolites in the end shift urine were 86.7 e 33.8 mg/g creatinine respectively. There is a significant linear correlation between personal styrene exposure and the excretion of styrene metabolites (R = 0.74). As expected the exposure markers of the workers of the two production sites resulted higher in the open process. The analytical results of both environmental and biological monitoring were all below the occupational exposure limits, confirming the efficacy of the protective devices.

MATERIALES
Número de producto
Marca
Descripción del producto

Sigma-Aldrich
Styrene, ReagentPlus®, contains 4-tert-butylcatechol as stabilizer, ≥99%
radiello Adsorbentes de cartucho, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
radiello Adsorbentes de cartucho, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
radiello Diffusive Bodies, white, configured for general use, pk of 20
Sigma-Aldrich
Mandelic acid, 99%
radiello Triangular Support Plate, pk of 20
Supelco
Styrene, analytical standard
radiello Adsorbentes de cartucho, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
radiello Diffusive Bodies, yellow, configured for reduced sampling rates, pk of 20
Sigma-Aldrich
Phenylglyoxylic acid, 97%
Sigma-Aldrich
(R)-(−)-Mandelic acid, ReagentPlus®, ≥99%
radiello Diffusive Bodies, blue, configured for sampling light sensitive compounds, pk of 20
radiello Adsorbentes de cartucho, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
Supelco
radiello Methylene Blue Calibration Standard for H2S (Hydrogen Sulfide), pkg of 100 mL
Sigma-Aldrich
(R)-(−)-Mandelic acid, 98%
radiello Outdoor Shelter, pk of 10
radiello BTEX/VOC Starter Kit, CS2 Desorption
Supelco
DL-Mandelic acid, analytical standard
radiello Vertical Adapter, threaded for standard use, pk of 20
radiello BTEX/VOC Starter Kit, Thermal Desorption
radiello Diffusive Bodies, permeative, configured for anaesthetic gases and vapors, pk of 20
radiello Barcode Labels, pk of 198
radiello Filtration Kit, pk of 20
radiello Anesthetic Gases and Vapor Sampler
Sigma-Aldrich
(R)-(−)-Mandelic acid, ChiPros®, produced by BASF, 99%
radiello Hydrogen Sulfide Starter Kit
Sigma-Aldrich
Phenylglyoxylic acid, purum, ≥98.0% (T)
Supelco
radiello BTEX Calibration Kit (Thermal Desorption)
radiello Empty Storage Tubes, polypropylene (with stopper), volume 12 mL, pk of 100
Supelco
radiello Aldehyde Calibration Standard, 50 μg/mL each component in acetonitrile, pkg of 10 mL