Saltar al contenido
Merck
  • Quantification of cocaine and metabolites in exhaled breath by liquid chromatography-high-resolution mass spectrometry following controlled administration of intravenous cocaine.

Quantification of cocaine and metabolites in exhaled breath by liquid chromatography-high-resolution mass spectrometry following controlled administration of intravenous cocaine.

Analytical and bioanalytical chemistry (2014-08-19)
Kayla N Ellefsen, Marta Concheiro, Olof Beck, David A Gorelick, Sandrine Pirard, Marilyn A Huestis
RESUMEN

Breath has been investigated as an alternative matrix for detecting recent cocaine intake; however, there are no controlled cocaine administration studies that investigated the drug's disposition into breath. Breath was collected from 10 healthy adult cocaine users by asking them to breathe into a SensAbues device for 3 min before and up to 22 h following 25 mg intravenous (IV) cocaine dosing on days 1, 5, and 10, and assayed with a validated liquid chromatography-high-resolution mass spectrometry (LC-HRMS) method to quantify breath cocaine, benzoylecgonine (BE), ecgonine methyl ester (EME), and norcocaine. The assay was linear from 25 to 1,000 pg/filter, extraction efficiencies were 83.6-126%, intra- and inter-assay imprecision was <10.6%, and bias was between -8.5 and 16.8%. No endogenous or exogenous interferences were observed for more than 75 tested. Analytes were generally stable under short-term storage conditions. Ion suppression was less than 46%. Of breath specimens collected after controlled cocaine administration, 2.6% were positive for cocaine (26.1-66 pg/filter, 1-9.5 h), 0.72% BE (83.3-151 pg/filter, 6.5-12.5 h), and 0.72% EME (50-69.1 pg/filter, 6.5-12.5 h); norcocaine was not detected. Methanolic extraction of the devices themselves, after filters were removed, yielded 19.2% positive cocaine tests (25.2-36.4 pg/device, 10 min-22 h) and 4.3% positive BE tests (26.4-93.7 pg/device, 10 min-22 h), explaining differences between the two extraction techniques. These results suggest that the device reflects the drug in oral fluid as well as lung microparticles, while the filter reflects only drug-laden microparticles. A sensitive and specific method for cocaine, BE, EME, and norcocaine quantification in breath was developed and validated. Cocaine in breath identifies recent cocaine ingestion, but its absence does not preclude recent use.

MATERIALES
Número de producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Hidróxido de amonio solution, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ácido fórmico, reagent grade, ≥95%
Sigma-Aldrich
Metanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acetonitrilo, ACS reagent, ≥99.5%
Sigma-Aldrich
Ácido fórmico, ACS reagent, ≥96%
Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
Sigma-Aldrich
Hidróxido de amonio solution, 28% NH3 in H2O, ≥99.99% trace metals basis
Supelco
Formato de amonio, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
Formato de amonio, reagent grade, 97%
Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Formato de amonio, ≥99.995% trace metals basis
Sigma-Aldrich
Ácido fórmico, ACS reagent, ≥88%
Sigma-Aldrich
Metanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Sigma-Aldrich
Metanol, Absolute - Acetone free
USP
Metanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Metanol, BioReagent, ≥99.93%
Supelco
Metanol, analytical standard
Supelco
Metanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Formato de amonio, BioUltra, ≥99.0% (calc. based on dry substance, NT)
Sigma-Aldrich
Acetonitrilo, biotech. grade, ≥99.93%
Sigma-Aldrich
Hidróxido de amonio solution, BioUltra, ~1 M NH3 in H2O (T)
Sigma-Aldrich
Acetonitrilo, electronic grade, 99.999% trace metals basis