Saltar al contenido
Merck
  • Aptamer-conjugated magnetic nanoparticles for extraction of adenosine from urine followed by electrospray ion mobility spectrometry.

Aptamer-conjugated magnetic nanoparticles for extraction of adenosine from urine followed by electrospray ion mobility spectrometry.

Journal of pharmaceutical and biomedical analysis (2015-01-28)
Marzieh Enteshari Najafabadi, Taghi Khayamian, Zahra Hashemian
RESUMEN

Magnetic nanoparticles (MNPs) conjugated with aptamer was developed for the selective extraction of adenosine in urine samples followed by electrospray ionization-ion mobility spectrometry (ESI-IMS). The ion mobility spectrum of adenosine showed two peaks at low concentrations and two more peaks related to dimer of adenosine at high concentrations. However, the ion mobility spectrum of eluent at low concentration showed only the peaks related to dimer of adenosine. In other words, aptamer captured two adenosine molecules between the top G-quartet and the two short stems, where they bonded to each other. The mass spectrum of the eluent also validated the presence of dimer (m/z 535.95). The effect of extraction parameters on extraction efficiency including sorbent amount, elution conditions (solvent type and volume) and adsorption conditions were investigated. Under the optimized conditions, the linear dynamic range was found to be 0.05-5.00 μg mL(-1) with detection limit of 0.02 μg mL(-1). The extraction efficiency was 94% and the relative standard deviation was 4% for three replicate measurements of adenosine at 0.25 μg mL(-1) in urine samples. As a practical application, the method was applied for the determination of adenosine in urine samples of patients with lung cancer, and the obtained results were in good agreement with those obtained by HPLC-UV method. Therefore, the proposed method is an alternative clinical analysis.

MATERIALES
Número de producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Alcohol etílico puro 200, Molecular Biology
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Alcohol etílico puro, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Hidróxido de amonio solution, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Ácido acético, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ácido acético, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Metanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Alcohol etílico puro, 200 proof, meets USP testing specifications
Sigma-Aldrich
Acetonitrilo, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
Sigma-Aldrich
Hidróxido de amonio solution, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
(3-aminopropil)trietoxisilano, 99%
Sigma-Aldrich
Alcohol etílico puro 190, for molecular biology
Sigma-Aldrich
Ácido acético, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Ácido acético solution, suitable for HPLC
Sigma-Aldrich
Metanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Glutaraldehyde solution, Grade I, 25% in H2O, specially purified for use as an electron microscopy fixative
Sigma-Aldrich
Metanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Etanol, BioUltra, Molecular Biology, ≥99.8%, (absolute alcohol, without additive, A15 o1)
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Adenosine, ≥99%
Sigma-Aldrich
Glutaraldehyde solution, Grade II, 25% in H2O
Sigma-Aldrich
Glutaraldehyde solution, 50 wt. % in H2O
Sigma-Aldrich
Etanol, purum, absolute ethanol, denaturated with 4.8% isopropanol, A15 IPA1, ≥99.8% (based on denaturant-free substance)
Sigma-Aldrich
Metanol, Absolute - Acetone free