Saltar al contenido
Merck
  • Optimization of magnetic stirring assisted dispersive liquid-liquid microextraction of rhodamine B and rhodamine 6G by response surface methodology: Application in water samples, soft drink, and cosmetic products.

Optimization of magnetic stirring assisted dispersive liquid-liquid microextraction of rhodamine B and rhodamine 6G by response surface methodology: Application in water samples, soft drink, and cosmetic products.

Talanta (2015-04-18)
Elias Ranjbari, Mohammad Reza Hadjmohammadi
RESUMEN

An exact, rapid and efficient method for the extraction of rhodamine B (RB) and rhodamine 6G (RG) as well as their determination in three different matrices was developed using magnetic stirring assisted dispersive liquid-liquid microextraction (MSA-DLLME) and HPLC-Vis. 1-Octanol and acetone were selected as the extraction and dispersing solvents, respectively. The potentially variables were the volume of extraction and disperser solvents, pH of sample solution, salt effect, temperature, stirring rate and vortex time in the optimization process. A methodology based on fractional factorial design (2(7)(-2)) was carried out to choose the significant variables for the optimization. Then, the significant factors (extraction solvent volume, pH of sample solution, temperature, stirring rate) were optimized using a central composite design (CCD). A quadratic model between dependent and independent variables was built. Under the optimum conditions (extraction solvent volume=1050µL, pH=2, temperature=35°C and stirring rate=1500rpm), the calibration curves showed high levels of linearity (R(2)=0.9999) for RB and RG in the ranges of 5-1000ngmL(-1) and 7.5-1000ngmL(-1), respectively. The obtained extraction recoveries for 100ngmL(-1) of RB and RG standard solutions were 100% and 97%, and preconcentration factors were 48 and 46, respectively. While the limit of detection was 1.15ngmL(-1) for RB, it was 1.23ngmL(-1) for RG. Finally, the MSA-DLLME method was successfully applied for preconcentration and trace determination of RB and RG in different matrices of environmental waters, soft drink and cosmetic products.

MATERIALES
Número de producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Sigma-Aldrich
2-Etil-1-hexanol, ≥99.6%
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Sigma-Aldrich
Dodecane, anhydrous, ≥99%
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Sigma-Aldrich
Acetonitrilo, electronic grade, 99.999% trace metals basis
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Sigma-Aldrich
1-Octanol, anhydrous, ≥99%
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Sigma-Aldrich
Acetona, ≥99%, FCC, FG
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Sigma-Aldrich
2-Etil-1-hexanol, ≥99%, FG
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Sigma-Aldrich
1-Octanol, ≥98%, FCC, FG
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Sigma-Aldrich
Acetona, natural, ≥97%
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Sigma-Aldrich
Metanol, suitable for NMR (reference standard)
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Sigma-Aldrich
1-Octanol, natural, ≥98%, FCC
En este momento no podemos mostrarle ni los precios ni la disponibilidad