Skip to Content
Merck
  • A novel approach for high sensitive determination of sulfur mustard by derivatization and isotope-dilution LC-MS/MS analysis.

A novel approach for high sensitive determination of sulfur mustard by derivatization and isotope-dilution LC-MS/MS analysis.

Talanta (2014-12-06)
Bin Xu, Cheng Zong, Zhiyong Nie, Lei Guo, Jianwei Xie
ABSTRACT

A new isotope-dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determination of sulfur mustard (SM) has been developed using a direct chemical derivatization method by nucleophile potassium thioacetate (PTA) in aqueous solution. The reaction conditions for derivatization, such as reaction temperature, time, solvent and concentration of PTA, were optimized for high performance. Reversed phase liquid chromatography was suitable for analysis of such a PTA derivatized SM in complex environmental samples. Compared with other conventional gas chromatography or gas chromatography-mass spectrometry methods for direct detection on SM, better sensitivity and selectivity were achieved by this direct derivatization and LC-MS/MS method, where SM can be detected as low as 0.05 ng/mL in acetonitrile. The linear range was from 0.1 to 1000 ng/mL. The relative standard deviation (RSD) of the intra-day precision was less than 11.8%, and RSD of the inter-day precision was less than 12.3%. The whole procedure for both derivatization and analysis was quick and simple, and the total time was less than 1h. This established method has been successfully employed for determination of spiking samples both in water and soil. A detection limit of 0.1 ng/mL was achieved for river water, while the SM in soil sample could be detected at 0.1 ng/g.

MATERIALS
Product Number
Brand
Product Description

Supelco
Dichloromethane solution, contains 10 % (v/v) methanol
Sigma-Aldrich
Poly(tetrafluoroethylene), powder, 200 μm particle size
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Hexane, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Supelco
Dichloromethane, Selectophore, ≥99.5%
Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
Sigma-Aldrich
Hexane, anhydrous, 95%
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Poly(tetrafluoroethylene), powder (free-flowing), 1 μm particle size
Sigma-Aldrich
Poly(tetrafluoroethylene), powder, 35 μm particle size
Sigma-Aldrich
Poly(tetrafluoroethylene), powder (free-flowing), ≤12 μm particle size
Sigma-Aldrich
Dichloromethane, suitable for HPLC, ≥99.9%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Poly(tetrafluoroethylene), powder, >40 μm particle size
Sigma-Aldrich
Dichloromethane, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Acetonitrile, ≥99.5%, ACS reagent
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Poly(tetrafluoroethylene), beads
Sigma-Aldrich
Poly(tetrafluoroethylene), powder, ≥350 μm particle size
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
Hexane, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99% (GC)
Sigma-Aldrich
Acetonitrile, AR, ≥99.5%
Sigma-Aldrich
Dichloromethane, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Hexane, ReagentPlus®, ≥99%
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Formic acid, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Dichloromethane, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich