Skip to Content
Merck
  • Determination of amphetamine and methylphenidate in exhaled breath of patients undergoing attention-deficit/hyperactivity disorder treatment.

Determination of amphetamine and methylphenidate in exhaled breath of patients undergoing attention-deficit/hyperactivity disorder treatment.

Therapeutic drug monitoring (2014-01-24)
Olof Beck, Niclas Stephanson, Sören Sandqvist, Johan Franck
ABSTRACT

It has been discovered recently that exogenous substances are detectable in exhaled breath after intake. Exhaled breath therefore constitutes a new possible matrix in clinical pharmacology and toxicology. The present work was aimed at exploring this possibility further by a study on patients treated for attention-deficit/hyperactivity disorder with D-amphetamine and methylphenidate. Thirteen patients (age range: 32-61 years; 5 women) were included in the study, and breath and urine samples were collected at different times in the dose interval. Analyses of breath and urine samples were done with liquid chromatography-mass spectrometry methods. Urine was examined for amphetamine, methylphenidate, and its metabolite ritalinic acid. Among the 9 patients who received D-amphetamine medication in daily doses of 20-100 mg, amphetamine was detected in all subjects in amounts ranging from 1200 to 30,800 picogram per filter. Among 8 patients receiving methylphenidate medication in daily doses of 80-400 mg, it was detected and quantified in 7 of the cases in amounts ranging from 150 to 10,400 picogram per filter and ritalinic acid was detected and quantified in 3 of the cases ranging from 35 to 360 picogram per filter. In 1 case, methylphenidate was only detectable in breath and urine, whereas ritalinic acid was quantifiable in urine, which could indicate noncompliance, with the 4 hours of dose regimen prescribed. In a number of cases, the sampling was performed 24 hours after the last dose intake. Identification of amphetamine and methylphenidate was based on correct chromatographic retention time and correct product ion ratio with detection performed in selected reaction monitoring mode. The results confirm that amphetamine is present in exhaled breath after intake and demonstrate for the first time the presence of methylphenidate and ritalinic acid after its intake. This gives further support to the potential use of exhaled breath for detecting drug intake.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
USP
Methyl alcohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, ≥99.5% (GC)
Sigma-Aldrich
Formic acid, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Formic acid, ACS reagent, ≥88%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile solution, contains 10.0% acetone, 0.05% formic acid, 40.0% 2-propanol
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (v/v) trifluoroacetic acid
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Ritalinic acid, 99% (CP)
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Supelco
Methanol, analytical standard