Yes, extending the spin times is sufficient. However, the time range would have to be experimentally determined by the user.
Select a Size
About This Item
Skip To
material
polyethylene cap
polyethylene liner
polypropylene tube
regenerated cellulose membrane
regenerated cellulose support
styrene-butadiene housing
Quality Level
sterility
non-sterile
product line
Amicon®
packaging
pkg of 24 pkg
pkg of 8 pkg
pkg of 96 pkg
manufacturer/tradename
Amicon® Ultra
sustainability
Greener Alternative Product
parameter
4 mL sample volume
technique(s)
protein extraction: suitable
protein purification: suitable
L
124 mm (4.88 in.)
diam.
17.3 mm
filtration area
3 cm2
volume
4 mL
working volume
≤4 mL
4 mL
pore size
10 kDa MWCO
greener alternative category
shipped in
ambient
1 of 4
This Item | UFC201024 | UFC9010 | UFC5010 |
|---|---|---|---|
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
| manufacturer/tradename Amicon® Ultra | manufacturer/tradename Amicon® Ultra | manufacturer/tradename Amicon® Ultra | manufacturer/tradename Amicon® Ultra |
| parameter 4 mL sample volume | parameter 2 mL sample volume | parameter 15 mL sample volume | parameter 0.5 mL sample volume |
| material polyethylene cap, polypropylene tube, regenerated cellulose support, polyethylene liner, styrene-butadiene housing, regenerated cellulose membrane | material polypropylene tube (for collection), regenerated cellulose membrane, styrene-butadiene housing | material polyethylene cap, polyethylene liner, polypropylene tube, regenerated cellulose membrane, regenerated cellulose support, styrene-butadiene housing | material polypropylene cap, polypropylene tube, regenerated cellulose membrane, styrene-butadiene housing |
| pore size 10 kDa MWCO | pore size 10 kDa MWCO | pore size 10 kDa MWCO | pore size 10 kDa MWCO |
| product line Amicon® | product line Amicon® | product line Amicon® | product line Amicon® |
General description
The vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 80-fold concentration. Solute polarization and subsequent fouling of the membrane are minimized by the vertical design, and a physical deadstop in the filter device prevents spinning to dryness and potential sample loss.
The concentrate is collected from the filter device sample reservoir using a pipetter, while the ultrafiltrate is collected in the provided centrifuge tube. The device can be spun in a swinging bucket or fixed angle rotor. With their vertical membrane design and deadstop, Amicon® Ultra 15 mL filters deliver the highest recovery with short spin times.
Application
- Ultrafiltration with 10,000 Dalton molecular weight cutoff Ultracel® membrane.
- Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms.
- Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLC.
- Concentration of dilute or pre-purified proteins from column eluents.
- Desalting, buffer exchange and protein dialysis.
- Size exclusion and protein fractionation.
Features and Benefits
- Ultracel® regenerated cellulose membrane with 10 kDa NMWCO delivers retentate recovery of greater than 90%.
- Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 5 minutes).
- Heat-sealed membrane minimizes downstream extractables.
- 100% integrity tested for reliable performance.
- Convenient sample monitoring with translucent housing and volume gradations.
- Direct pipette sample access eliminates processing step to recover concentrate.
- High concentration factors of 80–100X.
Legal Information
Storage Class Code
10-13 - German Storage Class 10 to 13
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Related Content
-
If my centrifuge only goes to 3,052 g, is it okay to centrifuge for a longer period of time to get the same separation? It is a swing-bucket centrifuge using the 10 MWCO filters.
1 answer-
Helpful?
-
-
is-it possible to wash and re-use the Amicon@Ultra-4 ? if yes how many time is_it possible to use them ?
1 answer-
The unit is for one-time use only.
Helpful?
-
-
How should the tubes be sterilized without damaging the membrane?
1 answer-
There are no validated sterilization methods for the Amicon Ultra devices. However, these devices can be "sanitized" with a spin cycle with 70% ethanol, followed by 2 rinsing spins with sterile water. It is recommended to filter the concentrated sample using a sterile 0.2 µm syringe filter (e.g., SLGVR33RS) after processing on the Amicons.
Helpful?
-
-
What speed can this product be centrifuged at ?
1 answer-
For this item when using a swinging-bucket rotor, spin the device at 4,000 × g maximum for approximately 10-40 minutes. When using a fixed-angle rotor, orient the device with the membrane panel facing up. For Amicon® Ultra 3K, 10K, 30K, and 50K devices, spin at 7,500 × g maximum for approximately 10-40 minutes. For Amicon® Ultra 100K devices, spin at 5,000 × g maximum for approximately 10-20 minutes.
Helpful?
-
-
How to use it...how much sample should be loaded and what will be the protocol of centrifugation while using?
1 answer-
The maximum initial sample 4 volume (mL). For more information please see page 36 in this product https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/260/181/br5002en-protein-prep-workflow-ms.pdf
Helpful?
-
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service