Skip to Content
Merck
  • Use of LC-MS-MS as an alternative to currently available immunoassay methods to quantitate corticosterone in egg yolk and albumen.

Use of LC-MS-MS as an alternative to currently available immunoassay methods to quantitate corticosterone in egg yolk and albumen.

Analytical and bioanalytical chemistry (2014-11-20)
Siegrid De Baere, Tom Rosendahl Larsen, Mathias Devreese, Patrick De Backer, Liesbeth De Neve, Graham Fairhurst, Luc Lens, Siska Croubels
ABSTRACT

Corticosterone (CORT) is the dominant plasma glucocorticoid in birds. There has been increasing interest in the function of CORT in avian egg yolk and in the potential to use CORT concentrations in eggs to quantify stress and to assess the effect of maternal stress on offspring. The concentration of CORT in egg yolk is most frequently assessed using enzyme or radioimmunoassays, alone or in combination with high-performance liquid chromatography. However, the quantification of CORT is frequently hampered by the presence of high concentrations of other steroid hormones which cross-react with the CORT antibody. As an alternative, we developed a sensitive and specific LC-MS-MS method. The sample-preparation procedure consisted of a protein-lipid precipitation step, followed by defatting and clean-up using a C18 SPE column. Chromatography was performed on an Acquity C18 BEH column (50 mm × 2.1 mm i.d., dp: 1.7 μm, run-time: 6 min), using 0.1% formic acid in both water (A) and acetonitrile (B) as mobile phases. The MS-MS instrument was operated in the positive-electrospray-ionization mode. The method was validated in-house according to European Guidelines (linearity, accuracy and precision, limits of quantification and detection, specificity, stability) and the results fell within the accepted ranges. The method was successfully used for the analysis of CORT in yolk and albumen of eggs collected from eight breeding lesser black-backed gulls at a Flemish coastal colony. CORT concentrations were in the range 42.4-166.3 pg g(-1) in albumen and < LOQ (75 pg g(-1))-762.5 pg g(-1) in yolk.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Progesterone, ≥99%
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (v/v) trifluoroacetic acid
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Testosterone, purum, ≥99.0% (HPLC)
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Progesterone, meets USP testing specifications
Sigma-Aldrich
Progesterone, powder, BioReagent, suitable for cell culture
Sigma-Aldrich
Testosterone, ≥98%
Sigma-Aldrich
Progesterone, γ-irradiated, BioXtra, suitable for cell culture
Sigma-Aldrich
Acetonitrile solution, contains 10.0% acetone, 0.05% formic acid, 40.0% 2-propanol
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Ethyl acetate, ReagentPlus®, ≥99.8%
Sigma-Aldrich
Hexane, anhydrous, 95%
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Hexane, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Ethyl acetate, ≥99%, FCC, FG
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, anhydrous, ≥99.5%
Sigma-Aldrich
Ethanol, absolute, sales not in Germany, ≥99.8% (vol.)
Sigma-Aldrich
Ethyl acetate, natural, ≥99%, FCC, FG
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
Ethyl acetate, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, ≥99.5%, ACS reagent
Sigma-Aldrich
Ethyl acetate, ACS reagent, ≥99.5%
Sigma-Aldrich
5-Pregnen-3β-ol-20-one, ≥98%
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Ethyl acetate