Skip to Content
Merck
  • Development and validation of an UPLC-MS/MS method for the quantification of ethoxzolamide in blood, brain tissue, and bioequivalent buffers: applications to absorption, brain distribution, and pharmacokinetic studies.

Development and validation of an UPLC-MS/MS method for the quantification of ethoxzolamide in blood, brain tissue, and bioequivalent buffers: applications to absorption, brain distribution, and pharmacokinetic studies.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-02-24)
Song Gao, Jing Zhao, Taijun Yin, Yong Ma, Beibei Xu, Anthony N Moore, Pramod K Dash, Ming Hu
ABSTRACT

The purpose of this study is to develop and validate an UPLC-MS/MS method to quantify ethoxzolamide in plasma (EZ) and apply the method to absorption, brain distribution, as well as pharmacokinetic studies. A C₁₈ column was used with 0.1% of formic acid in acetonitrile and 0.1% of formic acid in water as the mobile phases to resolve EZ. The mass analysis was performed in a triple quadrupole mass spectrometer using multiple reaction monitoring (MRM) with positive scan mode. The results show that the linear range of EZ is 4.88-10,000.00 nM. The intra-day variance is less than 12.43% and the accuracy is between 88.88 and 108.00%. The inter-day variance is less than 12.87% and accuracy is between 89.27 and 115.89%. Protein precipitation was performed using methanol to extract EZ from plasma and brain tissues. Only 40 μL of plasma is needed for analysis due to the high sensitivity of this method, which could be completed in less than three minutes. This method was used to study the pharmacokinetics of EZ in SD rats, and the transport of EZ in Caco-2 and MDCK-MDR1 overexpressing cell culture models. Our data show that EZ is not a substrate for p-glycoprotein (P-gp) and its entry into the brain may not limited by the blood-brain barrier.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Supelco
Methanol, analytical standard
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, Absolute - Acetone free
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, AR, ≥99.5%
Sulpiride, European Pharmacopoeia (EP) Reference Standard
USP
Methyl alcohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard