# Supel™-Select Polymeric SPE
## HLB and Ion-Exchange phases for a wide range of applications and pH conditions
Supel™-Select SPE phases are ideal for the solid phase extraction of a broad range of compounds from aqueous samples. While reversed-phase interactions dominate retention on the Supel™-Select HLB, and the retention mechanisms of the Supel™-Select SAX and SCX are predominately based on ion-exchange, the hydrophilic modifications of the styrene-based polymer backbone allow for retention and recovery of more polar compounds.
| | |
|--------------------------|----------------------------------------------------------------------|
| __HLB Phase Chemistry:__ | Hydrophilic modified styrene polymer |
| __SAX Phase Chemistry:__ | Quaternary amine functionalized hydrophilic modified styrene polymer |
| __SCX Phase Chemistry:__ | Sulfonic acid functionalized hydrophilic modified styrene polymer |
| __pH Compatibility:__ | 0-14 |
| __Particle Size:__ | 50-70 µM |
| __MS Suitability:__ | Yes |
| __Surface Area:__ | 160-420 m2/g |
| __Pore Volume:__ | 0.8-1.2 mL/g |
| __Pore Size:__ | 80-200 Å |
Table 1.
| | |
|------------------------------------|----------------------------------------------------------------------------------------------------------|
| Feature | Benefit |
| Hydrophilic modified styrene resin | Extract and recover a broad range of analytes (polar to non-polar, acidic to basic) from aqueous samples |
| Method simplicity | Save time, money, and frustration during method development |
| Greater capacity | Allows for smaller bed weights = smaller elution volumes = time savings in sample processing |
| Resistant to overdrying | More robust methodology and better reproducibility |
| Low UV and MS extractables | Lower background for greater sensitivity |
| Stringent production & QC | Greater lot-to-lot, tube-to-tube, and well-to-well consistency for improved accuracy and precision |
Table 2.
## High and Reproducible Recoveries
The hydrophilic, lipophilic balanced Supel™-Select HLB SPE allows users to extract a broad range of compounds using a single sorbent and generic methodology. Analyte recovery was high across all the compounds tested, and results were highly reproducible across three production lots.

## Minimal Extractables
Supel™-Select HLB SPE phases are quality controlled for both LC-UV and LC-MS/MS extractables. As assays require greater sensitivity, analytical “cleanliness” of both SPE phases and associated hardware becomes more critical.
In this simple test, acetonitrile was passed through both Supel™-Select HLB SPE tubes and the leading competitor’s tubes followed by LC-UV analysis.
Supel™-Select HLB SPE imparted less than 25% of UV extractables than the leading competitor.

__Figure 1.__
__Related Articles__
- [Determination of Formaldehyde and Acetaldehyde in Air Using DNPH Cartridges and Automated On-Line Desorption Followed by HPLC](https://www.sigmaaldrich.com/PL/en/technical-documents/protocol/environmental-testing-and-industrial-hygiene/air-testing/aldehydes-air-dnph)
- [Effect of Container Materials on Milk Off-Flavors](https://www.sigmaaldrich.com/PL/en/technical-documents/technical-article/analytical-chemistry/gas-chromatography/container-materials)
- [Pesticide Residue Analysis in Ginger Powder with QuEChERS](https://www.sigmaaldrich.com/PL/en/technical-documents/technical-article/analytical-chemistry/quechers/analysis-of-pesticide-residues-in-ginger-powder)
- [Analysis of Pesticide Residues in Pistachios Using QuEChERS Extraction and Cleanup with Supel™ QuE Z-Sep+](https://www.sigmaaldrich.com/PL/en/technical-documents/technical-article/analytical-chemistry/quechers/analysis-of-pesticide-residues-in-pistachios)
- [HybridSPE-Phospholipid Technology](https://www.sigmaaldrich.com/PL/en/technical-documents/technical-article/analytical-chemistry/small-molecule-hplc/hybridspe-precipitation-technology)
- [Impact of Mobile Phase Additives on LC-MS Sensitivity, Demonstrated using Spice Cannabinoids](https://www.sigmaaldrich.com/PL/en/technical-documents/technical-article/analytical-chemistry/small-molecule-hplc/lcms-spice-cannabinoids)
- [Solvent Analysis for 40 Per and Polyfluoroalkyl Substances](https://www.sigmaaldrich.com/PL/en/technical-documents/technical-article/analytical-chemistry/small-molecule-hplc/solvent-analysis-for-40-per-and-polyfluoroalkyl-substances)
- [Analysis of Drugs of Abuse in Urine](https://www.sigmaaldrich.com/PL/en/technical-documents/technical-article/analytical-chemistry/solid-phase-extraction/analysis-of-drugs-of-abuse-in-urine-after-cleanup-with-hlb)
- [View More](https://www.sigmaaldrich.com/PL/en/search/facet-search?focus=sitecontent&term=facet-search)
__Related Product Categories__
- [Solid Phase Extraction (SPE) and QuEChERS](https://www.sigmaaldrich.com/PL/en/products/analytical-chemistry/analytical-sample-preparation/spe-and-quechers)
Góra
__Zaloguj się, aby kontynuować__
Zaloguj się lub utwórz konto, aby kontynuować.
Zaloguj się__Nie masz konta użytkownika?__Zarejestruj
An unknown error has occured.