Skip to Content
Merck
  • Use of high-resolution proton nuclear magnetic resonance spectroscopy for rapid multi-component analysis of urine.

Use of high-resolution proton nuclear magnetic resonance spectroscopy for rapid multi-component analysis of urine.

Clinical chemistry (1984-03-01)
J R Bales, D P Higham, I Howe, J K Nicholson, P J Sadler
ABSTRACT

Numerous low-Mr metabolites--including creatinine, citrate, hippurate, glucose, ketone bodies, and various amino acids--have been identified in 400- and 500-MHz proton nuclear magnetic resonance (1H NMR) spectra of intact human urine. The presence of many of these was related to the specific condition of the donors: humans in different physiological states (resting, fasting, or post-exercise) and pathological conditions (e.g., diabetes mellitus, cadmium-induced renal dysfunction). We have also monitored the metabolism of simple nonendogenous compounds (methanol and ethanol) and of acetaminophen. The pH-dependencies of the NMR chemical shifts of some urine components are reported. Our studies show that high-resolution 1H NMR spectroscopy provides a fast, simple method for "fingerprint" identification of urinary compounds. In some cases, analytes can be quantified by standard additions or by comparing integrated peak areas for the metabolites with those for creatinine. Determinations of creatinine by 1H NMR spectroscopy compared well with those by an independent chemical assay based on the Jaffé reaction.

MATERIALS
Product Number
Brand
Product Description

Supelco
Glycine, analytical standard, for nitrogen determination according to Kjeldahl method
Supelco
Glycerin, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Glycine, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
3-Hydroxybutyric acid, 95%
Sigma-Aldrich
Dimethylamine, anhydrous, ≥99%
Sigma-Aldrich
Acetone, ≥99%, FCC, FG
Sigma-Aldrich
Hippuric acid, 98%
Sigma-Aldrich
Dodecanedioic acid, 99%
Supelco
Glycine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
L-(+)-Lactic acid solution, meets analytical specification of Ph. Eur., BP, 88-92% total acid basis
Sigma-Aldrich
L-(+)-Lactic acid solution, ~40% in H2O
Supelco
1-Butanol, analytical standard
Sigma-Aldrich
Glycine, BioUltra, Molecular Biology, ≥99.0% (NT)
Sigma-Aldrich
α-Ketoglutaric acid, 99.0-101.0% (T)
Sigma-Aldrich
Acetone, ACS spectrophotometric grade, ≥99.5%
Sigma-Aldrich
Chromium, powder, ≥99% trace metals basis, <45 μm
Sigma-Aldrich
Glycerol solution, 83.5-89.5% (T)
Sigma-Aldrich
Glycine, puriss. p.a., reag. Ph. Eur., buffer substance, 99.7-101% (calc. to the dried substance)
Sigma-Aldrich
Pyruvaldehyde solution, 40 wt. % in H2O
Sigma-Aldrich
Chromium, chips, 99.995% trace metals basis
Sigma-Aldrich
Glycine, 99%, FCC
Supelco
Acetone, analytical standard
Sigma-Aldrich
1-Butanol, anhydrous, 99.8%
Sigma-Aldrich
Chromium, powder, 99.5%, −100 mesh
Sigma-Aldrich
Glycine, meets analytical specification of Ph. Eur., BP, USP, 99-101% (based on anhydrous substance)
Sigma-Aldrich
Glycine, tested according to Ph. Eur.
Sigma-Aldrich
Glycine, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, ≥98.5%
Sigma-Aldrich
Glycine, BioXtra, ≥99% (titration)
Sigma-Aldrich
L-(+)-Lactic acid solution, 30% in H2O (by weight)
Sigma-Aldrich
α-Ketoglutaric acid, ≥98.5% (NaOH, titration)