If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf
Seleccione un Tamaño
| A ustedes/SKU | Disponibilidad | Precio |
|---|---|---|
2.5 L | Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad | 141,00 € |
2.5 L | Fecha estimada de envío12 de agosto de 2026desdeMerck Chemicals and LS SA | 149,00 € |
Acerca de este artículo
141,00 €
Nombre del producto
Potassium permanganate solution, c(KMnO4) = 0.05 mol/l (0.25 N), Titripur®
Quality Segment
product line
Titripur®
form
liquid
quality
Analyzed in our ISO 17025 accredited QC lab
reaction suitability
reaction type: Redox Reactions
concentration
0.05 M
technique(s)
titration: suitable
pH
7 ( in H2O)
density
1.0035 g/cm3
storage temp.
15-25°C
Application
- Rediscover Potassium Permanganate as a Stain for Basic Proteins on Ultrathin Sections at Transmission Electron Microscopy.: This study explores the reapplication of potassium permanganate as a staining agent for basic proteins in transmission electron microscopy, demonstrating its effectiveness in enhancing protein visualization (Zannino et al., 2023).
- Core-satellite surface imprinting polymer-based pipette tip solid-phase extraction for the colorimetric determination of pyrethroid metabolite.: This study presents a novel method using potassium permanganate in core-satellite surface imprinting for efficient extraction and colorimetric analysis of pyrethroid metabolites in environmental samples (Ye et al., 2020).
Features and Benefits
ChemiSphere™ App for Digital Data Transfer to OMNIS Titration Instruments from Metrohm
Discover the ChemiSphere™ App for secure, rapid data transfer to OMNIS titrators, enhancing efficiency in the titration workflow with Titripur® and Aquastar® reagents. ChemiSphere App for Digital Reagent Data Transfer
SmartChemicals for Digital Data Transfer to Mettler Toledo Titration Instruments
Explore digital data transfer with our SmartChemicals for Mettler Toledo titrators—fast, easy, and safe, accelerating the titration process with Titripur®, Aquastar® reagents, and Certipur® and Aquastar® standards. Supelco® SmartChemicals for Titration
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.
Packaging
Analysis Note
Amount-of-substance concentration 0.04975 - 0.05025 mol/L
Measurement uncertainty ± 0.00015 mol/L
Traceability NIST SRM
The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 8040 di-sodium oxalate) by means of volumetric standard di-sodium oxalate (article number 1.02407), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.
Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.
Legal Information
1 of 1
Este artículo | |||
|---|---|---|---|
| description c(KMnO4) = 0.05 mol/l (0.25 N), Titripur® | description standardised against oxalate c(KMnO4) = 0.02 mol/l (0.1 N), Titripur®, reag. USP | description c(KMnO4) = 0.002 mol; standardised against di-sodium oxalate (CRM), Titripur® | description standardised against sodium thiosulfate c(KMnO4) = 0.02 mol/l (0.1 N), Titripur®, reag. Ph. Eur. |
| reaction suitability reaction type: Redox Reactions | reaction suitability reaction type: Redox Reactions | reaction suitability reaction type: Redox Reactions | reaction suitability reaction type: Redox Reactions |
| technique(s) titration: suitable | technique(s) titration: suitable | technique(s) titration: suitable | technique(s) titration: suitable |
| product line Titripur® | product line Titripur® | product line Titripur® | product line Titripur® |
| form liquid | form liquid | form liquid | form liquid |
| pH 7 ( in H2O) | pH 8 (20 °C in H2O) | pH - | pH 8 (20 °C in H2O) |
| Quality Level 200 | Quality Level 100 | Quality Level 200 | Quality Level 200 |
Still not finding the right product?
Explore all of our products under Potassium permanganate solution
hcodes
pcodes
Hazard Classifications
Aquatic Chronic 2
Clase de almacenamiento
12 - Non Combustible Liquids
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
-
How can I determine the shelf life / expiration / retest date of this product?
1 respuesta-
¿Le ha resultado útil?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 respuesta-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
¿Le ha resultado útil?
-