material

polyethersulfone
polypropylene screen
polyurethane adhesive

Quality Level

manufacturer/tradename

Pellicon®

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse)
5-35 L/min recirculation rate at 0.4 bar (6 psi)
7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

technique(s)

analytical sample preparation: suitable
protein purification: suitable

H

9.0 cm (3.5 in.)

L

21 cm (8.3 in.)

W

17.8 cm (7.0 in.)

filtration area

2 m2

membrane nominal area

2 m2

gravimetric extractables

≤1500 mg/m2

matrix

Biomax®

pore size

300 kDa NMWCO

pH

1-14

¿Está buscando productos similares? Visita Guía de comparación de productos

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 4

Este artículo
P2B030V20P2B005V20P2B050V20
matrix

Biomax®

matrix

Biomax®

matrix

Biomax®

matrix

Biomax®

pore size

300 kDa NMWCO

pore size

30 kDa NMWCO

pore size

5 kDa NMWCO

pore size

50 kDa NMWCO

material

polyethersulfone , polyurethane adhesive, polypropylene screen

material

polyethersulfone , polypropylene screen, polyurethane adhesive

material

polyethersulfone , polypropylene screen, polyurethane adhesive

material

polyethersulfone , polypropylene screen, polyurethane adhesive

technique(s)

analytical sample preparation: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward), 5-35 L/min recirculation rate at 0.4 bar (6 psi)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

General description

The Pellicon® 2 Ultrafiltration BIOMAX 100 Maxi Cassette sets the standard in cassette-style tangential flow filtration devices. P2B300V20 was designed with process scale-up and applications development in mind.

Millipore′s BIOMAX 100 polyethersulfone membrane has void-free structures that guard against leakage of solutes through microdefects normally associated with voids beneath the thin skins of conventional UF membranes. These void-free membranes are more permeable, resulting in high-flux with equivalent or superior product retention. These void-free membranes provide the advantages of fast, high yield processing and smaller systems.

The Pellicon® 2 Maxi Ultrafiltration BIOMAX Module feature a filtration area of 2 m2 with a pore size of 300 kDa NMWCO.

Application

Concentration, desalting or buffer exchange of:
  • Protein solutions
  • Polysaccharide solutions
  • Virus suspensions


Harvest, washing or clarification of:
  • Cell cultures and lysates
  • Colloidal suspensions
  • Viral cultures

Features and Benefits

  • Type V screen (open channel)
  • Leading-edge void- free membranes to match virtually any separation challenge
  • Short flow path for higher flux and higher resolution separation capability
  • Choice of flow channel configuration providing process optimization capability
  • Predictable, fast, scale-up
  • True linear scalability from laboratory size modules to industrial assemblies for processing thousands of liters
  • Brings higher resolution, improved yields and superior back-pressure resistance
  • Ultracel membranes are composite membranes cast on a microporous substrate for defect-free membranes with superior

Analysis Note

Gravimetric Extractables: after a water flush

Other Notes

Prefiltration Rquirements: 100 µm
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

BIOMAX is a registered trademark of Merck KGaA, Darmstadt, Germany
Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany

Clase de almacenamiento

10 - Combustible liquids

wgk_germany

WGK 2


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Questions

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico