Seleccione un Tamaño
Acerca de este artículo
Saltar a
material
polysulfone (21 CFR 177.1655)
silicone O-ring (21 CFR 177.2600)
silicone gasket (21 CFR 177.2600)
Quality Level
sterility
non-sterile
product line
Lynx®
parameter
27.3 L/min flow rate at 1.38 bar (20 psi) and 25 °C (77°F)
4-40 °C operating temperature (39-104 °F)
4.1 bar max. pressure (60 psi) (operating pressure)
fitting
3/8 in. inlet hose barb for 0.25 in (7.1 mm) I.D.
3/8 in. outlet hose barb for 0.25 in (7.1 mm) I.D.
Categorías relacionadas
1 of 4
Este artículo | SSCSHB2A01 | SSCSHB1A01 | SSCMHB3A24 |
|---|---|---|---|
| material polysulfone (21 CFR 177.1655), silicone gasket (21 CFR 177.2600), silicone O-ring (21 CFR 177.2600) | material polysulfone (21 CFR 177.1655), silicone O-ring (21 CFR 177.2600), silicone gasket (21 CFR 177.2600) | material polysulfone (21 CFR 177.1655), silicone O-ring (21 CFR 177.2600), silicone gasket (21 CFR 177.2600) | material polysulfone (21 CFR 177.1655), silicone O-ring (21 CFR 177.2600), silicone gasket (21 CFR 177.2600) |
| fitting 3/8 in. inlet hose barb for 0.25 in (7.1 mm) I.D., 3/8 in. outlet hose barb for 0.25 in (7.1 mm) I.D. | fitting 1/2 in. inlet hose barb for 0.43 in (10.9 mm) I.D., 1/2 in. outlet hose barb for 0.43 in (10.9 mm) I.D. | fitting 1/4 in. inlet hose barb for 0.19 in (4.8 mm) I.D., 1/4 in. outlet hose barb for 0.19 in (4.8 mm) I.D. | fitting 3/8 in. inlet hose barb for 0.25 in (7.1 mm) I.D. |
| product line Lynx® | product line Lynx® | product line Lynx® | product line Lynx® |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
| parameter 27.3 L/min flow rate at 1.38 bar (20 psi) and 25 °C, 4.1 bar max. pressure (60 psi) (operating pressure) | parameter 4-40 °C operating temperature (39-104 °F), 4.1 bar max. pressure (60 psi) (operating pressure), 71.9 L/min flow rate at 1.38 bar (20 psi) and 25 °C | parameter 4-40 °C operating temperature (39-104 °F), 4.1 bar max. pressure (60 psi) (operating pressure), 9.5 L/min flow rate at 1.38 bar (20 psi) and 25 °C (77°F) | parameter 27.3 L/min flow rate at 1.38 bar (20 psi) and 25 °C, 4-40 °C operating temperature (39-104 °F), 4.1 bar max. pressure (60 psi) (operating pressure) |
| Quality Level 400 | Quality Level 400 | Quality Level 400 | Quality Level 400 |
General description
The SSCSHB3A01 Lynx S2S connector set is constructed of a female coupling and a male coupling. With these two components assembled, the sterile fluid path is enabled. Once assembled, the two components cannot be disassembled, reducing the risk of sterility breach.
This Lynx S2S unit has a 3/8 inch. diameter and a hose barb inlet/outlet connection.
Safe, Disposable Connectors
The Lynx S2S connector is disposable and intended for single-use, one-time actuation. There are no parts to clean-in-place, and the risk of contamination is reduced.
Sterility Assurance During Actuation
The Lynx S2S connector is 100% air-integrity tested in manufacturing. Connector sets were tested utilizing an aerosolized bacterial challenge method with 106 B. diminuta and direct bacterial soiling method with B. diminuta, assuring a sterile connection can be made in non-classified areas.
Application
By design, a sterile connector should protect the fluid path by never exposing it to the open environment. The Lynx® S2S connector employs a solid plug, not a membrane or peel strip, which creates a gap for ingress of contamination during the connection process. The Lynx® S2S design provides high-pressure sealing and a flow path that remains completely closed, minimizing the risk of bacterial intrusion. It will secure the fluid path at a sterility assurance level (SAL) of 10-6 under the most rigorous conditions. Once assembled, the two components cannot be disassembled, reducing the risk of sterility breach. The male-female connection design adds safety to the process, limiting the risks of wrong connection in critical steps. Lynx® S2S: the only plug style device with a SAL of 10-6
Preparation Note
Gamma compatible up to 45 kGy; Autoclave once for 30 minutes @ 130 °C. Do not steam in place.
Legal Information
Cumpla las GMP con el programa Emprove®.
Acelere la cualificación, mantenga la conformidad y ahorre tiempo con Emprove® Dossiers.
Nota: será redirigido a EmproveSuite.com. Su nombre de usuario y contraseña son independientes de SigmaAldrich.com y pueden diferir.
Regístrese gratis y acceda a Emprove® Dossiers en cuestión de minutos. Actualice su plan de suscripción para desbloquear contenidos avanzados y personalizados en la Emprove® Suite
¿No encuentra lo que busca? Visite la página de ayuda del programa Emprove®..
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Active Filters
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico