Manifold (5-valve) with AseptiQuik® S connector, sterile; γ-irradiated, volume 60 mL

Synonym(e):

Bottle, Bottle Application

Anmelden zur Ansicht der Organisations- und Vertragspreise.

Größe auswählen

Ansicht ändern
Ihnen/SKUVerfügbarkeitPreis

Über diesen Artikel

UNSPSC Code:
41104105
Preise und Verfügbarkeit sind derzeit nicht verfügbar.
Technischer Dienst
Benötigen Sie Hilfe? Unser Team von erfahrenen Wissenschaftlern ist für Sie da.
Unterstützung erhalten


Quality Segment

material

PETG body, PETG container, TPE tubing, polycarbonate connector

sterility

sterile; γ-irradiated

product line

NovaSeptum® SURe

storage condition

room temperature

parameter

0.30 bar max. pressure (4.35 psi), 4-40 °C temp. range (39-104 °F)

capacity

60 mL

volume

60 mL

fitting

inlet connection (TPE), Luer-Lok® outlet connection (3-piece), outlet connection (containing a male, female and an injection site)

application(s)

sterile sampling

General description

The NovaSeptum® SURe sterile sampling assembly is for single-use manufacturing processes, where aseptic connection and disconnection is necessary.
The product comes as a manifolded unit with 5 bottles and connects via AseptiQuik® S connector. The bio-neutral plastic bottles are ideal for all tests. The closed design ensures your sample will be isolated from point of sample to analysis, reducing the risk of losing valuable product and maintaining the integrity of your fluid samples.

Application

Sterility testing, bioburden, pyrogenic testing, endotoxin testing, chemical analysis, pH analysis, fermentation applications or any other routine lab testing
Supported Liquid Extraction

Features and Benefits

  • Product design ensures process integrity and a representative sample from single-use manufacturing processes
  • Industry-standard aseptic connection and disconnection for easy integration into your single-use process
  • Other container options available: bags, bottles, syringes, and conical tubes
  • Stocked and ready-to-ship for fast delivery

Packaging

5 units per box (5*60mL)

Preparation Note

Assembled under ISO Clean Room Class 8 conditions in a facility certified to ISO 14644-1 standards.

Analysis Note

All component materials, in contact with sampling liquid, meet the criteria for Class VI testing based on USP 88 Biological Reactivity, in vivo.

Other Notes

Not autoclavable

Legal Information

AseptiQuik is a registered trademark of Colder Products Company
Luer-Lok is a registered trademark of Becton-Dickinson & Co.
NOVASEPTUM is a registered trademark of Merck KGaA, Darmstadt, Germany

Ähnliche Artikel vergleichen

Vollständigen Vergleich anzeigen

Unterschiede anzeigen

1 of 1

Dieser Artikel
AC46454445744
description

Manifold (5-valve) with AseptiQuik® S connector, sterile; γ-irradiated, volume 60 mL

description

Manifold (5-valve) with AseptiQuik® S connector, sterile; γ-irradiated, volume 5 mL (20 mL)

description

Manifold (5-valve) with Inlet C-Flex® Tubing, sterile; β-irradiated, volume 5 mL (20 mL)

description

Manifold (5-valve) with Inlet C-Flex® Tubing, sterile; β-irradiated, volume 100 mL

fitting

outlet connection (containing a male, female and an injection site), inlet connection (TPE), Luer-Lok® outlet connection (3-piece)

fitting

Luer-Lok® outlet connection (3-piece), outlet connection (containing a male, female and an injection site), inlet connection (Silicone)

fitting

outlet connection (containing a male, female and an injection site), Luer-Lok® outlet connection (3-piece), inlet connection (containing a male, female and an injection site), Luer-Lok® inlet connection (3-piece)

fitting

Luer-Lok® outlet connection (3-piece), outlet connection (containing a male, female and an injection site), Luer-Lok® inlet connection (3-piece), inlet connection (containing a male, female and an injection site)

product line

NovaSeptum® SURe

product line

NovaSeptum® SURe

product line

NovaSeptum® SURe

product line

NovaSeptum® SURe

material

polycarbonate connector, PETG container, TPE tubing, PETG body

material

polycarbonate container, silicone tubing, polypropylene body, polycarbonate connector

material

polycarbonate Luer lock, silicone tubing, C-Flex tubing, polycarbonate container, polycarbonate body

material

C-Flex tubing, polyethylene body, TPE tubing, polyethylene container, polycarbonate Luer lock

sterility

sterile; γ-irradiated

sterility

sterile; γ-irradiated

sterility

sterile; β-irradiated

sterility

sterile; β-irradiated

application(s)

sterile sampling

application(s)

sterile sampling

application(s)

sterile sampling

application(s)

sterile sampling

Quality Level

400

Quality Level

400

Quality Level

400

Quality Level

400


Still not finding the right product?




Bleiben Sie mit dem Emprove®-Programm GMP-konform

Beschleunigen Sie die Qualifizierung, halten Sie die Vorschriften ein und sparen Sie Zeit mit Emprove® Dossiers.

Dossiers herunterladen

Hinweis: Sie werden zu EmproveSuite.com weitergeleitet. Ihr Benutzername und Passwort sind von SigmaAldrich.com getrennt und können abweichen.

Registrieren Sie sich kostenlos und erhalten Sie innerhalb weniger Minuten Zugang zu Emprove® Dossiers. Aktualisieren Sie Ihr Abonnement, um erweiterte und angepasste Inhalte in der Emprove® Suite freizuschalten.

Sie finden nicht, was Sie suchen? Besuchen Sie die Emprove® Programm-Hilfeseite.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Können Sie Ihr Produkt oder Ihre Lot-/Chargennummer nicht finden?

Produktnummern werden bei der Anzeige auf der Website mit Packungsgrößen/-menge kombiniert (Beispiel: T1503-25G). Bitte stellen Sie sicher NUR die Produktnummer in das Feld Produktnummer eingeben (Beispiel: T1503).

Beispiel:

T1503
Produktnummer
-
25G
Packungsgröße/Menge

Weitere Beispiele:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

eingeben als 1.000309185)

Haben Sie Probleme? Sie können sich jederzeit an uns wenden Technischer Dienst zur Unterstützung



Questions

Reviews

No rating value

Active Filters