Direkt zum Inhalt
Merck
  • Statin treatment and diabetes affect myeloperoxidase activity in maintenance hemodialysis patients.

Statin treatment and diabetes affect myeloperoxidase activity in maintenance hemodialysis patients.

Clinical journal of the American Society of Nephrology : CJASN (2007-08-21)
Peter Stenvinkel, Ernesto Rodríguez-Ayala, Ziad A Massy, Abdul Rashid Qureshi, Peter Barany, Bengt Fellström, Olof Heimburger, Bengt Lindholm, Anders Alvestrand
ZUSAMMENFASSUNG

Myeloperoxidase (MPO), which is secreted during activation of neutrophils, may serve as one mechanistic link among persistent inflammation, oxidative stress, and cardiovascular disease. This study related MPO activity to inflammatory and oxidative stress biomarkers, comorbidity, and ongoing medication in prevalent hemodialysis (HD) patients. In a cross-sectional evaluation of 115 prevalent (vintage 25 mo) HD patients (62 men; 63 +/- 1 yr), data on comorbidity (Davies score), diabetes, medication (statins and antihypertensive drugs), nutritional status (subjective global assessment), blood lipids (cholesterol, HDL cholesterol, and triglycerides), inflammatory biomarkers (serum albumin, C-reactive protein, TNF-alpha, and IL-6), oxidative stress biomarkers (pentosidine, 8-hydroxydeoxyguanosine, and MPO activity) were recorded. Patients with MPO activity greater than the median had significantly (P < 0.05) lower serum albumin levels (33.2 +/- 0.7 versus 35.0 +/- 0.5 g/L), higher 8-hydroxydeoxyguanosine levels (1.26 +/- 0.08 versus 1.05 +/- 0.06 ng/ml), and a lower prevalence of statin treatment (18 versus 36%). Therefore, the median MPO activity was significantly (P < 0.05) lower (17.7 versus 26.6 deltaOD630/min per mg protein) in the subgroup of 31 HD patients with ongoing statin treatment. In a multiple regression model, correction for the impact of age, gender, vintage, serum cholesterol, serum albumin, comorbidity, diabetes, and statin use, only diabetes (P < 0.01) and statin use (P < 0.01) were significantly associated to MPO activity. Fourteen patients who had diabetes and were receiving statin treatment had markedly (P = 0.001) lower median (19.9 versus 41.2 deltaOD630/min per mg protein) MPO activity compared with 18 who had diabetes and were not taking statins. This cross-sectional study suggests that both diabetes and statin treatment affect MPO activity in prevalent HD patients.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Ethyl alcohol, Pure 200 proof, Molecular Biology
Sigma-Aldrich
Aceton, ACS reagent, ≥99.5%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Aceton, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Aceton, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, meets USP testing specifications
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, anhydrous, ≥99.5%
Sigma-Aldrich
Ethyl alcohol, Pure 190 proof, for molecular biology
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
Zink, dust, <10 μm, ≥98%
Sigma-Aldrich
Ethanol, BioUltra, Molecular Biology, ≥99.8%, (absolute alcohol, without additive, A15 o1)
Sigma-Aldrich
Aceton, ACS reagent, ≥99.5%
Sigma-Aldrich
Zink, granular, 20-30 mesh, ACS reagent, ≥99.8%
Supelco
Aceton, analytical standard
Sigma-Aldrich
Zink, powder, <150 μm, 99.995% trace metals basis
Sigma-Aldrich
Inosin, ≥99% (HPLC)
Sigma-Aldrich
Dimethylamin -Lösung, 40 wt. % in H2O
Supelco
Ethanol, wasserfrei, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Trimethylamin-N-oxid, 95%
Sigma-Aldrich
Cadaverin, 95%
Supelco
Ethanol, standard for GC
Sigma-Aldrich
Ethanol, purum, fine spirit, denaturated with 4.8% methanol, F25 METHYL1, ~96% (based on denaturant-free substance)
Sigma-Aldrich
Dimethylamin -Lösung, 2.0 M in THF
Sigma-Aldrich
Phenylessigsäure, 99%
Sigma-Aldrich
Dimethylamin, anhydrous, ≥99%
Sigma-Aldrich
Aceton, histological grade, ≥99.5%
Sigma-Aldrich
Trimethylamin -Lösung, 43.0-49.0% in H2O (T)
Supelco
Aceton, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Zink, foil, thickness 0.25 mm, 99.9% trace metals basis
Supelco
Ethanol-50, 50 mg/dL in H2O, ampule of 10 × 1.2 mL, certified reference material, Cerilliant®