Direkt zum Inhalt
Merck
  • Online background cleanup followed by high-performance liquid chromatography with tandem mass spectrometry for the analysis of perfluorinated compounds in human blood.

Online background cleanup followed by high-performance liquid chromatography with tandem mass spectrometry for the analysis of perfluorinated compounds in human blood.

Journal of separation science (2014-11-12)
Liangpo Liu, Jianwen She, Xueqin Zhang, Jie Zhang, Meiping Tian, Qingyu Huang, Syed Ali Musstjab Akber Shah Eqani, Heqing Shen
ZUSAMMENFASSUNG

In this study, a novel method for the analysis of perfluorinated compounds in whole blood has been developed and validated. The method was developed by using a conventional reversed-phase C18 column as a trapping column for the elimination of background contamination and high-performance liquid chromatography with tandem mass spectrometry for the target compounds analysis. The trapping column provided fast online separation of the background contamination of perfluorinated compounds. In this developed method, the limits of detection for different perfluorinated compounds ranged from 0.06 to 0.14 ng/mL. It is notable that the limit of detection (0.07 ng/mL) for perfluorooctanoic acid was improved significantly after the elimination of background contamination. The method was also validated in terms of sensitivity, accuracy, and precision. The recoveries ranged from 66.8 to 111.9%, with relative standard deviations from 2.1 to 15.3%. Our preliminary data suggest that the novel method based on trapping column cleanup followed by high-performance liquid chromatography with tandem mass spectrometry could be applied in studies on the human exposure to perfluorinated compounds.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
tert-Butylmethylether, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Ammoniumacetat, ACS reagent, ≥97%
Sigma-Aldrich
tert-Butylmethylether, ACS reagent, ≥99.0%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
tert-Butylmethylether, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Ammoniumacetat, ≥99.99% trace metals basis
Supelco
Ammoniumacetat, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Perfluorbuttersäure, 98%
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Perfluoroctansäure, 95%
Sigma-Aldrich
Zirkonium(IV)-oxychlorid Octahydrat, reagent grade, 98%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Ammoniumacetat, Molecular Biology, ≥98%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
tert-Butylmethylether, reagent grade, ≥98%
Supelco
Heptafluorbuttersäure, suitable for ion chromatography, ≥99.5% (GC)
Sigma-Aldrich
Methanol, Absolute - Acetone free
Sigma-Aldrich
Ammoniumacetat -Lösung, Molecular Biology, 7.5 M
USP
Methylalkohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
2-Thiobarbitursäure, ≥98%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Supelco
Methanol, analytical standard
Sigma-Aldrich
Ammoniumacetat, 99.999% trace metals basis
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Perfluornonansäure, 97%
Supelco
Heptadecafluoroctansulfonsäure -Lösung, 100 μg/mL in methanol, analytical standard