A novel method for characterization and comparison of reversed-phase column selectivity.

Journal of chromatography. A (2014-08-27)
Jixia Wang, Chaoran Wang, Zhimou Guo, Xuefang Dong, Yuansheng Xiao, Xingya Xue, Xiuli Zhang, Xinmiao Liang
RÉSUMÉ

Characterization of reverse-phase column selectivity is helpful for chromatographers to select an optimal column. A novel method, based on linear solvation energy relationships (LSERs) combined with fundamental retention equations, was developed to characterize and compare reversed-phase column selectivity. The retention times of 25 elaborately selected solutes on 12 reversed-phase columns were determined in three linear gradient elutions. Using these retention times, fundamental retention equations were acquired by a complex sample analysis software system (CSASS). When 0%, 10%, 20%, 30%, 40% and 50% acetonitrile were introduced into the fundamental retention equations, the corresponding retention factors were predicted and used to obtain LSER equations by multiple linear regression. In the gradient elution, the retention times of solutes could be accurately determined and the excessively long or short analysis time could be avoided. As the retention factor (lnkw) at a hypothetical 0% organic modifier closely reflected properties of columns, coefficients of LSERs equations obtained based on lnkw were employed to discuss the properties of different stationary phases. An angle and a spider diagram based on solvation energy vectors were used to compare selectivity differences between stationary phases, which provided a visual means for users to select appropriate columns with orthogonal or similar selectivity. These results of column selectivities were compared with those obtained by geometric orthogonality approach, and a consistent result was acquired. Finally, Click TE-CD and XCharge C18PN with highest difference in column selectivity were applied to the separation of Psoralea corylifolia extraction.

MATÉRIAUX
Numéro du produit
Marque
Description du produit

Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Ethyl alcohol, Pure 200 proof, Molecular Biology
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acétonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acide formique, reagent grade, ≥95%
Sigma-Aldrich
Méthanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, meets USP testing specifications
Sigma-Aldrich
Acétonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acide formique, ACS reagent, ≥96%
Sigma-Aldrich
Acétonitrile, anhydrous, 99.8%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, anhydrous, ≥99.5%
Sigma-Aldrich
Acide formique, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
Méthanol, anhydrous, 99.8%
Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acétonitrile, ≥99.9% (GC)
Sigma-Aldrich
Acide formique, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
Méthanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Acide formique, ACS reagent, ≥88%
Sigma-Aldrich
Éthanol, ACS reagent, prima fine spirit, without additive, F15 o1
Sigma-Aldrich
Méthanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Éthanol, BioUltra, Molecular Biology, ≥99.8%, (absolute alcohol, without additive, A15 o1)
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Éthanol, purum, absolute ethanol, denaturated with 4.8% isopropanol, A15 IPA1, ≥99.8% (based on denaturant-free substance)
Sigma-Aldrich
Méthanol, Absolute - Acetone free