Skip to Content
Merck

PHR1214

Methyl salicylate

Pharmaceutical Secondary Standard; Certified Reference Material

Synonym(s):

2-Hydroxybenzoic acid methyl ester, Methyl 2-hydroxybenzoate, Oil of wintergreen, Wintergreen oil

Sign In to View Organizational & Contract Pricing.

Select a Size

3.2 ML

CZK 2,450.00

CZK 2,450.00


Please contact Customer Service for Availability

Request a Bulk Order

About This Item

Linear Formula:
2-(HO)C6H4CO2CH3
CAS Number:
Molecular Weight:
152.15
UNSPSC Code:
41116107
NACRES:
NA.24
PubChem Substance ID:
EC Number:
204-317-7
Beilstein/REAXYS Number:
971516
MDL number:

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

Product Name

Methyl salicylate, Pharmaceutical Secondary Standard; Certified Reference Material

InChI key

OSWPMRLSEDHDFF-UHFFFAOYSA-N

InChI

1S/C8H8O3/c1-11-8(10)6-4-2-3-5-7(6)9/h2-5,9H,1H3

SMILES string

COC(=O)c1ccccc1O

grade

certified reference material
pharmaceutical secondary standard

agency

traceable to USP 1537450

vapor density

5.26 (vs air)

vapor pressure

1 mmHg ( 54 °C)

API family

methyl salicylate

CofA

current certificate can be downloaded

autoignition temp.

847 °F

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

refractive index

n20/D 1.536 (lit.)

bp

222 °C (lit.)

mp

−8-−7 °C (lit.)

density

1.174 g/mL at 25 °C (lit.)

application(s)

pharmaceutical (small molecule)

format

neat

storage temp.

2-8°C

Quality Level

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
1437450W274518PHL82239
application(s)

pharmaceutical (small molecule)

application(s)

pharmaceutical (small molecule)

application(s)

flavors and fragrances

application(s)

-

technique(s)

HPLC: suitable, gas chromatography (GC): suitable

technique(s)

-

technique(s)

-

technique(s)

-

format

neat

format

neat

format

-

format

-

Quality Level

300

Quality Level

-

Quality Level

400

Quality Level

-

grade

certified reference material, pharmaceutical secondary standard

grade

pharmaceutical primary standard

grade

FG, Halal, Kosher

grade

primary reference standard

storage temp.

2-8°C

storage temp.

-

storage temp.

-

storage temp.

-

Analysis Note

These secondary standards offer multi-traceability to the US and EP primary standards, where they are available.

Application

Methyl salicylate may be used as a pharmaceutical reference standard for the determination of the analyte in pharmaceutical formulations by chromatography[1][2] and voltammetry[3] techniques.
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

General description

Pharmaceutical secondary standards for application in quality control, provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards.
Methyl salicylate is one of the common ingredients present in topical analgesics and rubifacients. It is prescribed for the management of minor muscle aches and pains.[4]

Other Notes

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.
This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.
To see an example of a Certificate of Analysis for this material enter LRAC3556 in the slot below. This is an example certificate only and may not be the lot that you receive.

signalword

Danger

Hazard Classifications

Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Dam. 1 - Repr. 2 - Skin Sens. 1B

Storage Class

10 - Combustible liquids

wgk

WGK 2

flash_point_f

204.8 °F - closed cup

flash_point_c

96 °C - closed cup


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Optimization and validation of liquid chromatography and headspace-gas chromatography based methods for the quantitative determination of capsaicinoids, salicylic acid, glycol monosalicylate, methyl salicylate, ethyl salicylate, camphor and l-menthol in a topical formulation
Pauwels J, et al.
Journal of Pharmaceutical and Biomedical Analysis, 60(3), 51-58 (2012)
Determination of salicylic acid in pharmaceutical formulations and foods by differential-pulse voltammetry using a glassy carbon electrode
Fung YS and Luk SF
Analyst, 114(8), 943-945 (1989)
Fourier transform mid-infrared (MIR) and near-infrared (NIR) spectroscopy for rapid quality assessment of Chinese medicine preparation Honghua Oil
Wu YW, et al.
Journal of Pharmaceutical and Biomedical Analysis, 46(3), 498-504 (2008)
Agata Bartyzel et al.
Analytica chimica acta, 707(1-2), 204-209 (2011-10-27)
N,N'-bis-(α-methylsalicylidene)-2,2-dimethyl-1,3-propanediimine (SBTD) modified silica gel was prepared and used as sorbent for solid phase extraction of Cr(III) ions from aqueous solution. This sorbent showed a high sorption affinity for Cr(III) while recovery of Cr(VI) was very low. The analyte ion
J S Valdez et al.
Journal of chromatography. B, Biomedical sciences and applications, 729(1-2), 163-171 (1999-07-20)
Analytical methods using gas chromatography-flame ionization detection (GC-FID) for the quantitation of camphor and menthol and GC-MS for the quantitation of methyl salicylate have been developed for measurement of low concentrations from human plasma. Anethole serves as the internal standard

Questions

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service