The treatment with acetonitrile removes the matrix effect, including the proteins, from the samples. This means that the cortisol bound to albumin and other proteins is eliminated. The assay specifically measures the free cortisol (non-bound cortisol).
Acerca de este artículo
Saltar a
reactividad de especies
human
Nivel de calidad
fabricante / nombre comercial
Milliplex®
técnicas
multiplexing: suitable
entrada
cell culture supernatant(s)
plasma
serum
método de detección
fluorometric (Luminex® xMAP®)
Condiciones de envío
wet ice
temp. de almacenamiento
2-8°C
1 of 4
Este artículo | HCYTA-60K-PX38 | HCYP2MAG-62K | HCYP3MAG-63K |
|---|---|---|---|
| species reactivity human | species reactivity human | species reactivity human | species reactivity human |
| manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® |
| Quality Level 200 | Quality Level 200 | Quality Level 200 | Quality Level 200 |
| technique(s) multiplexing: suitable | technique(s) multiplexing: suitable | technique(s) multiplexing: suitable | technique(s) multiplexing: suitable |
| detection method fluorometric (Luminex® xMAP®) | detection method fluorometric (Luminex® xMAP®) | detection method fluorometric (Luminex xMAP) | detection method fluorometric (Luminex xMAP) |
| storage temp. 2-8°C | storage temp. 2-8°C | storage temp. - | storage temp. - |
Descripción general
Aplicación
- MILLIPLEX® Qualified assays undergo rigorousassay development, verification, and Quality Control testing to achieve optimalperformance.
- Simultaneously analyze up to 48 cytokine,chemokine, and growth factor biomarkers with bead-based multiplex assays usingLuminex technology, in human serum, plasma and cell culture samples.
- Available analytes: sCD40L, EGF, Eotaxin, FGF-2,FLT-3L, Fractalkine, G-CSF, GM-CSF, GROα, IFNα2, IFNγ, IL-1α, IL-1β, IL-1RA,IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IL-9, IL-10, IL-12 (p40), IL-12(p70), IL-13, IL-15, IL-17A, IL-17E/IL-25, IL-17F, IL-18, IL-22, IL-27, IP-10,MCP-1, MCP-3, M-CSF, MDC, MIG, MIP-1α, MIP-1β, PDGF-AA, PDGF-AB/BB, RANTES,TGFα, TNFα, TNFβ, VEGF-A
Características y beneficios
- This panel is fully configurable, with options for custom bead premixing, fixed premixed and bulk premixed panels.
- Save time and resources by simultaneously analyzing up to 48 analytes of your choice in a single sample
- Requires a small sample volume (25 µL/well)
- Choose same day or overnight incubation
- Reliable and accurate performance with proven lot-to-lot consistency
- Ready-to-use reagents
- Comes with everything you need to run your assay
- Includes a Serum Matrix to mimic the native sample environment in serum and plasma samples
- Includes high and low Quality Controls
Envase
Nota de preparación
Información legal
Cláusula de descargo de responsabilidad
Producto relacionado
Palabra de señalización
Danger
Frases de peligro
Consejos de prudencia
Clasificaciones de peligro
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
Órganos de actuación
Respiratory Tract
Código de clase de almacenamiento
10 - Combustible liquids
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Contenido relacionado
Encuentre los inmunoanálisis que permiten explorar las citocinas que intervienen en la neuroinmunología y la neuroinflamación, así como los biomarcadores de enfermedades neurodegenerativas.
Cytokine multiplex assays allow researchers to easily investigate the immune system. The MILLIPLEX® Human Cytokine/Chemokine/Growth Factor Multiplex Panels A and B are multiplex assays for cytokine detection that each offer a unique combination of 48 analytes that can be simultaneously analyzed in a small sample volume.
Immunology multiplex assays, like MILLIPLEX® assays, allow researchers to investigate more immune biomarkers simultaneously, saving time and resources.
Discover the benefits of MILLIPLEX® multiplex assays, based on Luminex® xMAP® multiplex assay technology, that provide consistent, high-quality results and see how these multiplex biomarker Luminex® assays are being used to advance research.
-
When precipitating proteins (albumin and globulins) from plasma or serum samples using an Acetonitrile solution, does cortisol, which is bound to albumin & globulin, dissociate into the solution or get removed along with the protein precipitate?
1 respuesta-
¿Le ha resultado útil?
-
-
Could you please provide the expected sample ranges for the Milliplex Human Cytokine Panel A (HCYTA-60K)?
1 respuesta-
The serum and plasma sample values for the HCYTA-60K kit are provided. It's important to note that these values should be used as a guideline only. This data is based on a small sample size without effort for randomization and is not a true reference range.
¿Le ha resultado útil?
-
-
Could you provide a recommendation for sample preparation for placenta and HCYTA-60K assay?
1 respuesta-
The Milliplex assays have not been tested or verified for use with placenta tissue homogenates. However, a reference is available using placenta homogenates in the Human Cytokine Panel 1 (HCYTOMAG-60K).
The samples were prepared as follows:
Placental homogenate: Fragments of frozen placental tissue were transferred to propylene tubes containing lysis buffer and a cocktail of protease inhibitors. The placenta samples were homogenized using an electric homogenizer on ice. After homogenization, the homogenates were centrifuged, and the protein concentration in the supernatant was measured and stored for further analysis.Reference: Molás RB, Ribeiro MR, Ramalho Dos Santos MJC, et al. The involvement of annexin A1 in human placental response to maternal Zika virus infection Antiviral Res. 2020 Jul; 179:104809.
¿Le ha resultado útil?
-
-
What type of IL-12p40 was detected in the Human Cytokine Panel A (HCYTA-60K) – IL-12p40 monomer or IL-12p40 total (both monomer and homodimer)?
1 respuesta-
The capture in the assay detects the IL-12p40 monomer, and the standard used is also the IL-12p40 monomer. However, specific testing has not been conducted to determine if it also detects the homodimer.
¿Le ha resultado útil?
-
-
Can the Milliplex Human Cytokine/Growth Factor Panel A (HCYTA-60K) measure IFNa2a or IFNA2B?
1 respuesta-
Based on the antibody and standard specification sheets, the kit detects both IFNa2a and IFNa2B. The capture antibody is listed as an IFNa2B antibody and does not mention IFNa2a. However, the standard is recombinant IFNa2a.
¿Le ha resultado útil?
-
-
Are the standards used in Human Cytokine Panel A expressed in E. Coli?
1 respuesta-
The IFNa2 protein is expressed in yeast, while IL-12p40, IL-12p70, and IL-27 proteins are expressed in HEK293. All the other proteins are expressed in E. Coli.
¿Le ha resultado útil?
-
-
Do you have any information about BPA, specifically bisphenol A from the plastic used in the immunoassay kits?
1 respuesta-
The plastic materials used in the immunoassay kit are BPA-free according to the manufacturer's websites.
¿Le ha resultado útil?
-
-
Is it better to use EDTA vacutainers than heparinized vacutainers when collecting blood from plasma? Does this apply to both humans and mice?
1 respuesta-
For our Milliplex assays, EDTA plasma is preferred. Care must be taken when using heparin as an anticoagulant since an excess of heparin will provide falsely high values. Use no more than 10 IU heparin per mL of blood collected.
¿Le ha resultado útil?
-
-
Is there an alternative method if a bath sonicator is not available for sonication of beads as mentioned in the Milliplex protocols? Can vortexing for a longer period serve as an alternative?
1 respuesta-
The Milliplex assays recommend using a sonicator (water bath, Branson B200 or equivalent). Sonication helps break up any aggregated beads and beads stuck to the vial to reduce aggregation and improve counts. If a bath sonicator is not available, you can vortex for up to 2 minutes.
¿Le ha resultado útil?
-