Please see the full dimensions below:
Number of wells - 96
Well shape - round
Well bottom - flat
Plate length - 127.9 mm
Plate width - 85.6 mm
Plate Height - 14.6 mm
Column offset, left edge to A1 center - 14.4 mm
Row offset, top edge to A1 center - 11.4 mm
Well spacing – 9 mm
Well diameter - 6.2 mm
Well height - 12.1 mm
Seleccione un Tamaño
Acerca de este artículo
Saltar a
Materiales
Durapore PVDF membrane
clear acrylic plate
flat bottom wells
Nivel de calidad
descripción
Non-sterile, clear 96-well filter plate with 0.45 um pore size Hydrophobic PVDF membrane for Avidin-biotin Linkages, DNA-binding Proteins, Protein Binding & PAMPA. Comes in a pack of 50.
with underdrain
esterilidad
non-sterile
uso
Manual
Características
hydrophobic
lid
envase
pkg of 50 plates
fabricante / nombre comercial
MultiScreen®
técnicas
cell based assay: suitable
dot blot: suitable
parallel artificial membrane permeation assay (PAMPA): suitable
filtración área
0.3 cm2
placa tamaño
96 well
pocillo volumen máximo
300 μL
volumen de trabajo
50-250 μL
Matriz
Immobilon®-P
tamaño de poro
0.45 μm pore size
tipo de unión
high binding surface
compatibilidad
manifold only
Condiciones de envío
ambient
Categorías relacionadas
1 of 4
Este artículo | MSIPN4B10 | MSHVN4B | MSIPS4W10 |
|---|---|---|---|
| binding type high binding surface | binding type high binding surface | binding type low binding surface | binding type high binding surface |
| manufacturer/tradename MultiScreen® | manufacturer/tradename MultiScreen® | manufacturer/tradename MultiScreen® | manufacturer/tradename MultiScreen® |
| pore size 0.45 μm pore size | pore size 0.45 μm pore size | pore size 0.45 μm pore size | pore size 0.45 μm pore size |
| material PVDF membrane (hydrophobic), flat bottom wells, acrylic | material Barex® , PVDF membrane (hydrophobic), flat bottom wells, titanium dioxide | material Barex® , PVDF membrane (hydrophilic), flat bottom wells, titanium dioxide | material PVDF membrane (hydrophobic), acrylic , flat bottom wells |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility sterile |
| feature hydrophobic, lid | feature hydrophobic, lid | feature hydrophilic, lid | feature hydrophobic, lid |
Aplicación
- como soporte de membrana artificial y como placa receptora en análisis de permeación con membranas artificiales en paralelo (PAMPA) para determinar las permeabilidad de las oximas[1]
- en el enzimoinmunoanálisis de recuento de puntos (ELISpot)[2]
- en ELISpot específico de hemocianina de lapa californiana (KLH) para la identificación de células específicas de antígeno (Ag)[3]
Información legal
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Artículos
Combining solubility & PAMPA assays streamlines drug permeability testing.
This is a white paper on the Evaluation of the reproducibility of Parallel Artificial Membrane Permeation Assays (PAMPA) using MultiScreen® Filter Plates.
This is a protocol for a Membrane Integrity test for Lipid-PAMPA Artificial Membranes
Protocolos
Assays that predict passive absorption of orally administered drugs have become increasingly important in the drug discovery process. As previously described by Faller and Kansy such assays provide rapid, low cost and automation friendly methods to measure a compound’s passive permeability.
Guidelines for various bioassays on the MultiScreen system, which makes it possible to carry out an assay from sample incubation to scintillation counting in a 96-well plate.
Contenido relacionado
MultiScreen Immobilon-P Filtration Plates
-
I am looking for the geometry data of the plate. Respectively the height, width, and length of the full plate plus the the diameter and depth of one well.
1 respuesta-
¿Le ha resultado útil?
-
-
Could you please explain the meaning of the terms "donor," "acceptor," "receiver," and "collection" in relation to MAIPN4550 and MAIPN4510 filter plates?
1 respuesta-
The donor plate is also known as the filter plate, while the acceptor plate can be referred to as the acceptor, receiver, or collection plate. For detailed information on the PAMPA assay, you can refer to the provided link. Additionally, a datasheet is available that reviews some of the donor and acceptor plates. The donor plates include MAIPN4550 and MAIPNTR10. An alternative donor plate option is S2EM004M99, which is a 'MA' classic designed plate. It is important to note that any plate starting with 'MS---' in the catalog number cannot be used.
As for the acceptor plates, several options are available, such as MSSACCEPT0R, MATRNPS50, and MSCPNUV40.
Moreover, tech notes for the automation of PAMPA-Lipid on the Sciclone ALH 3000 workstation and the automation of PAMPA-HDM using a MultiScreen® Filter Plate on a Beckman Biomek® FX Workstation are also available. An article titled "Evaluation of the reproducibility of Parallel Artificial Membrane Permeation Assays (PAMPA)" provides further insights into the topic.
¿Le ha resultado útil?
-
Filtros activos
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico