Saltar al contenido
Merck

MAIPN4550

Placa de 96 pocillos Multiscreen®, membrana de PVDF hidrófoba

pore size 0.45 μm, non-sterile

Sinónimos:

Placa de PVDF de 96 pocillos, Placa de membrana de PVDF, Placa hidrófoba de 96 pocillos

Iniciar sesión para ver los posibles precios especiales de su organización

Seleccione un Tamaño

En este momento no podemos mostrarle ni los precios ni la disponibilidad

Acerca de este artículo

Código UNSPSC:
41104923
eCl@ss:
32039006
NACRES:
NB.22

Saltar a

Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle

Materiales

Durapore PVDF membrane
clear acrylic plate
flat bottom wells

Nivel de calidad

descripción

Non-sterile, clear 96-well filter plate with 0.45 um pore size Hydrophobic PVDF membrane for Avidin-biotin Linkages, DNA-binding Proteins, Protein Binding & PAMPA. Comes in a pack of 50.
with underdrain

esterilidad

non-sterile

uso

Manual

Características

hydrophobic
lid

envase

pkg of 50 plates

fabricante / nombre comercial

MultiScreen®

técnicas

cell based assay: suitable
dot blot: suitable
parallel artificial membrane permeation assay (PAMPA): suitable

filtración área

0.3 cm2

placa tamaño

96 well

pocillo volumen máximo

300 μL

volumen de trabajo

50-250 μL

Matriz

Immobilon®-P

tamaño de poro

0.45 μm pore size

tipo de unión

high binding surface

compatibilidad

manifold only

Condiciones de envío

ambient

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 4

Este artículo
MSIPN4B10MSHVN4BMSIPS4W10
binding type

high binding surface

binding type

high binding surface

binding type

low binding surface

binding type

high binding surface

manufacturer/tradename

MultiScreen®

manufacturer/tradename

MultiScreen®

manufacturer/tradename

MultiScreen®

manufacturer/tradename

MultiScreen®

pore size

0.45 μm pore size

pore size

0.45 μm pore size

pore size

0.45 μm pore size

pore size

0.45 μm pore size

material

PVDF membrane (hydrophobic), flat bottom wells, acrylic

material

Barex® , PVDF membrane (hydrophobic), flat bottom wells, titanium dioxide

material

Barex® , PVDF membrane (hydrophilic), flat bottom wells, titanium dioxide

material

PVDF membrane (hydrophobic), acrylic , flat bottom wells

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

sterile

feature

hydrophobic, lid

feature

hydrophobic, lid

feature

hydrophilic, lid

feature

hydrophobic, lid

Aplicación

La placa de filtración MultiScreen®-IP, de 0,45 μm, transparente, no estéril, se ha utilizado:
  • como soporte de membrana artificial y como placa receptora en análisis de permeación con membranas artificiales en paralelo (PAMPA) para determinar las permeabilidad de las oximas[1]
  • en el enzimoinmunoanálisis de recuento de puntos (ELISpot)[2]
  • en ELISpot específico de hemocianina de lapa californiana (KLH) para la identificación de células específicas de antígeno (Ag)[3]

Información legal

Immobilon is a registered trademark of Merck KGaA, Darmstadt, Germany
MULTISCREEN is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Claudia Giesecke et al.
Journal of immunology (Baltimore, Md. : 1950), 200(12), 3981-3992 (2018-05-08)
There are currently limited insights into the progression of human primary humoral immunity despite numerous studies in experimental models. In this study, we analyzed a primary and related secondary parenteral keyhole limpet hemocyanin (KLH) immunization in five human adults. The
A C Belkina et al.
Journal of dental research, 99(7), 855-862 (2020-03-19)
Periodontitis (PD) is a common source of uncontrolled inflammation in obesity-associated type 2 diabetes (T2D). PD apparently fuels the inflammation of T2D and associates with poor glycemic control and increased T2D morbidity. New therapeutics are critically needed to counter the
Hee Chun Jeong et al.
Bioorganic & medicinal chemistry, 17(17), 6213-6217 (2009-08-12)
A series of fluorinated oxime compounds was designed and synthesized in order to probe the effect of fluorine substitution on reactivation of inhibited acetylcholinesterase (AChE) by organophosphorus agents. Permeability measurements, using the Parallel Artificial Membrane Permeation Assays (PAMPA) method, were

Artículos

Combining solubility & PAMPA assays streamlines drug permeability testing.

This is a white paper on the Evaluation of the reproducibility of Parallel Artificial Membrane Permeation Assays (PAMPA) using MultiScreen® Filter Plates.

This is a protocol for a Membrane Integrity test for Lipid-PAMPA Artificial Membranes

Protocolos

Assays that predict passive absorption of orally administered drugs have become increasingly important in the drug discovery process. As previously described by Faller and Kansy such assays provide rapid, low cost and automation friendly methods to measure a compound’s passive permeability.

Guidelines for various bioassays on the MultiScreen system, which makes it possible to carry out an assay from sample incubation to scintillation counting in a 96-well plate.

Contenido relacionado

Preguntas

1–2 de 2 Preguntas  
  1. I am looking for the geometry data of the plate. Respectively the height, width, and length of the full plate plus the the diameter and depth of one well.

    1 respuesta
    1. Please see the full dimensions below:
      Number of wells - 96
      Well shape - round
      Well bottom - flat
      Plate length - 127.9 mm
      Plate width - 85.6 mm
      Plate Height - 14.6 mm
      Column offset, left edge to A1 center - 14.4 mm
      Row offset, top edge to A1 center - 11.4 mm
      Well spacing – 9 mm
      Well diameter - 6.2 mm
      Well height - 12.1 mm

      ¿Le ha resultado útil?

  2. Could you please explain the meaning of the terms "donor," "acceptor," "receiver," and "collection" in relation to MAIPN4550 and MAIPN4510 filter plates?

    1 respuesta
    1. The donor plate is also known as the filter plate, while the acceptor plate can be referred to as the acceptor, receiver, or collection plate. For detailed information on the PAMPA assay, you can refer to the provided link. Additionally, a datasheet is available that reviews some of the donor and acceptor plates. The donor plates include MAIPN4550 and MAIPNTR10. An alternative donor plate option is S2EM004M99, which is a 'MA' classic designed plate. It is important to note that any plate starting with 'MS---' in the catalog number cannot be used.

      As for the acceptor plates, several options are available, such as MSSACCEPT0R, MATRNPS50, and MSCPNUV40.

      Moreover, tech notes for the automation of PAMPA-Lipid on the Sciclone ALH 3000 workstation and the automation of PAMPA-HDM using a MultiScreen® Filter Plate on a Beckman Biomek® FX Workstation are also available. An article titled "Evaluation of the reproducibility of Parallel Artificial Membrane Permeation Assays (PAMPA)" provides further insights into the topic.

      ¿Le ha resultado útil?

Revisiones

Sin puntuación

Filtros activos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico