Placa Pellicon® 2 con ultrafiltración Biomax®

filtration area 0.5 m2, NMWCO 5 kDa

Sinónimos:

Pellicon® 2 Cassette Ultrafiltration Module Biomax-5 V 0.5 m2

Iniciar sesión para ver los posibles precios especiales de su organización

Seleccione un Tamaño

1 EA

3960,00 €

3960,00 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad


Acerca de este artículo

Código UNSPSC:
23151806

Saltar a

Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle

Materiales

polyethersulfone
polypropylene screen
polyurethane adhesive

Nivel de calidad

fabricante / nombre comercial

Pellicon®

Parámetros

0.33 bar max. transmembrane pressure (5 psig) (reverse)
5-35 L/min recirculation rate at 0.4 bar (6 psi)
7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

técnicas

analytical sample preparation: suitable
protein purification: suitable

Altura

2.16 cm (0.85 in.)

Longitud

21 cm (8.3 in.)

Anchura

17.8 cm (7.0 in.)

filtración área

0.5 m2

Área nominal de la membrana

0.5 m2

extraíbles gravimétricos

≤1500 mg/m2

Matriz

Biomax®

tamaño de poro

5 kDa NMWCO

pH

1-14

¿Está buscando productos similares? Visita Guía de comparación de productos

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 4

Este artículo
P2B005A05P2B008V05P2B010V05
matrix

Biomax®

matrix

Biomax®

matrix

Biomax®

matrix

Biomax®

pore size

5 kDa NMWCO

pore size

5 kDa NMWCO

pore size

8 kDa NMWCO

pore size

10 kDa NMWCO

material

polyethersulfone , polyurethane adhesive, polypropylene screen

material

polyethersulfone , polypropylene screen, polyurethane adhesive

material

polyethersulfone , polypropylene screen, polyurethane adhesive

material

polyethersulfone , polypropylene screen, polyurethane adhesive

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward), 5-35 L/min recirculation rate at 0.4 bar (6 psi)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 4-6 L/min recirculation rate at 1.4 bar (20 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

technique(s)

protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

Descripción general

The Pellicon® 2 Ultrafiltration BIOMAX 5 Cassette sets the standard in cassette-style tangential flow filtration devices. P2B005V05 was designed with process scale-up and applications development in mind.

Millipore′s BIOMAX 5 polyethersulfone membrane has void-free structures that guard against leakage of solutes through microdefects normally associated with voids beneath the thin skins of conventional UF membranes. These void-free membranes are more permeable, resulting in high-flux with equivalent or superior product retention. These void-free membranes provide the advantages of fast, high yield processing and smaller systems.

The Pellicon® 2 Cassette Ultrafiltration BIOMAX Module feature a filtration area of 0.5 m2 with a pore size of 5 kDa NMWCO.

Aplicación

Concentration, desalting or buffer exchange of:
  • Protein solutions
  • Polysaccharide solutions
  • Virus suspensions


Harvest, washing or clarification of:
  • Cell cultures and lysates
  • Colloidal suspensions
  • Viral cultures

Características y beneficios

  • Type V screen (open channel)
  • Leading-edge void- free membranes to match virtually any separation challenge
  • Short flow path for higher flux and higher resolution separation capability
  • Choice of flow channel configuration providing process optimization capability
  • Predictable, fast, scale-up
  • True linear scalability from laboratory size modules to industrial assemblies for processing thousands of liters
  • Brings higher resolution, improved yields and superior back-pressure resistance
  • Ultracel membranes are composite membranes cast on a microporous substrate for defect-free membranes with superior

Nota de análisis

Gravimetric Extractables: after a water flush

Otras notas

Prefiltration Rquirements: 100 µm
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Información legal

BIOMAX is a registered trademark of Merck KGaA, Darmstadt, Germany
Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany

Código de clase de almacenamiento

10 - Combustible liquids

Clase de riesgo para el agua (WGK)

WGK 2


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Preguntas

Revisiones

Sin puntuación

Filtros activos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico