Seleccione un Tamaño
| Talla/SKU | Disponibilidad | Precio |
|---|---|---|
1 ea | Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad | 684,00 € |
Acerca de este artículo
684,00 €
Quality Segment
material
TPE seal, composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene cap (for end), polypropylene screen
product line
Pellicon®
feature
holdup volume 3.6 mL (in feed channel)
manufacturer/tradename
Pellicon®
parameter
2.75 bar max. inlet pressure (40 psi) at 50 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C
technique(s)
analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration), tangential flow filtration (TFF): suitable
H
0.8 cm (0.33 in.)
L
20.6 cm (8.1 in.)
W
5.6 cm (2.2 in.)
filtration area
88 cm2
membrane area
88 cm2
gravimetric extractables
≤1500 mg/m2
matrix
Ultracel® (Membrane)
pore size
30 kDa NMWCO
pH
2-13
shipped in
ambient
General description
La casete Pellicon® 3 con membrana Ultracel® está diseñada para la filtración de proteínas terapéuticas (como anticuerpos monoclonales) y proteínas recombinantes y no recombinantes.
Este dispositivo de ultrafiltración P3C030D00 Pellicon® 3 se caracteriza por un tamaño de poro de NMWCO de 30 kDa, una superficie de filtración de 88 cm2, una membrana PLCTK y dimensiones de 3,8 cm (Al) x 17,8 cm (An) x 20,6 cm (L).
Features and Benefits
- Robustas y fiables: ideales para los procesos de filtración más exigentes de hoy en día
- Alto rendimiento: producen una excelente resolución, rendimientos y resistencia a la contrapresión
- Recuperación óptima del producto gracias a la probada tecnología de membrana
- Tecnología libre de huecos: membranas sin huecos de última generación resuelven prácticamente cualquier desafío de separación
- Adhesión superior, sin defectos: Ultracel® utiliza membranas compuestas moldeadas sobre un sustrato microporoso
- Fabricación automatizada: ofrece un rendimiento, una uniformidad y una fiabilidad insuperables
- Cuidado e instalación fáciles: fácil de instalar y mantener
Analysis Note
Other Notes
Legal Information
1 of 1
Este artículo | |||
|---|---|---|---|
| description filtration area 88 cm2, NMWCO 30 kDa, holdup volume, 3.6 mL (in feed channel) | description filtration area 88 cm2, NMWCO 30 kDa, holdup volume, 1.5 mL (in feed channel) | description filtration area 1.14 m2, NMWCO 3 kDa, Holdup volume 170 mL | description filtration area 0.57 m2, NMWCO 3 kDa |
| pore size 30 kDa NMWCO | pore size 30 kDa NMWCO | pore size 3 kDa NMWCO | pore size 3 kDa NMWCO |
| technique(s) protein purification: suitable (concentration), analytical sample preparation: suitable, buffer exchange: suitable | technique(s) buffer exchange: suitable, analytical sample preparation: suitable, protein purification: suitable (concentration) | technique(s) protein purification: suitable (concentration), analytical sample preparation: suitable, buffer exchange: suitable | technique(s) protein purification: suitable (concentration), analytical sample preparation: suitable, buffer exchange: suitable |
| filtration area 88 cm2 | filtration area 88 cm2 | filtration area 1.14 m2 | filtration area 0.57 m2 |
| matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) |
| material polypropylene cap (for end), TPE seal, composite regenerated cellulose (CRC) membrane, polypropylene screen | material polypropylene screen, TPE seal, polypropylene cap (for end), composite regenerated cellulose (CRC) membrane | material composite regenerated cellulose (CRC) , TPE seal, polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated) | material stainless steel cap (for end; polypropylene-encapsulated), composite regenerated cellulose (CRC) , TPE seal, polypropylene screen |
| parameter 2.75 bar max. inlet pressure (40 psi) at 50 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 80 psi max. transmembrane pressure at 4-40 °C, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 4-6 L/min-m2 recirculation rate | parameter 6.9 bar max. inlet pressure (100 psi), 4-6 L/min-m2 recirculation rate, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 40 psi max. transmembrane pressure at 4-50 °C, 80 psi max. transmembrane pressure at 4-40 °C, 2.75 bar max. inlet pressure (40 psi) at 50 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 5.5 bar max. inlet pressure (80 psi) at 40 °C | parameter 40 psi max. transmembrane pressure at 4-50 °C, 4-6 L/min-m2 recirculation rate, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours) | parameter 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 80 psi max. transmembrane pressure at 4-40 °C |
Still not finding the right product?
Explore all of our products under Placa Pellicon® 3 con membrana Ultracel®
Clase de almacenamiento
10 - Combustible liquids
¿Qué está pasando?
WGK 2
Listados normativos
Los listados normativos se proporcionan para los productos químicos principalmente. Para los productos no químicos sólo se puede proporcionar información limitada. Si no hay ninguna entrada, significa que ninguno de los componentes está en la lista. Es obligación del usuario garantizar el uso seguro y legal del producto.
64-19-7
Cumpla las GMP con el programa Emprove®.
Acelere la cualificación, mantenga la conformidad y ahorre tiempo con Emprove® Dossiers.
Nota: será redirigido a EmproveSuite.com. Su nombre de usuario y contraseña son independientes de SigmaAldrich.com y pueden diferir.
Regístrese gratis y acceda a Emprove® Dossiers en cuestión de minutos. Actualice su plan de suscripción para desbloquear contenidos avanzados y personalizados en la Emprove® Suite
¿No encuentra lo que busca? Visite la página de ayuda del programa Emprove®..
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
¿Le resulta difícil encontrar su producto o lote/número de lote?
Cómo encontrar el número de producto
Las referencias de los producto se combinan con los tamaños de envase y las cantidades cuando se muestran en la página web, por ejemplo: T1503-25G. Asegúrese de introducir el número de producto ÚNICAMENTE en el campo del Número de producto (ejemplo: T1503).
Ejemplo:
Otros ejemplos
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
introducir como 1.000309185)
¿Tienes problemas? Siéntase libre de contactar Servicio técnico para asistencia


