Saltar al contenido
Merck
  • Bulk derivatization and cation exchange restricted access media-based trap-and-elute liquid chromatography-mass spectrometry method for determination of trace estrogens in serum.

Bulk derivatization and cation exchange restricted access media-based trap-and-elute liquid chromatography-mass spectrometry method for determination of trace estrogens in serum.

Analytica chimica acta (2015-01-20)
Jana Beinhauer, Liangqiao Bian, Hui Fan, Marek Šebela, Maciej Kukula, Jose A Barrera, Kevin A Schug
RESUMEN

Estrone (E1), estradiols (α/β-E2), and estriol (E3) are four major metabolically active estrogens exerting strong biological activities at very low circulating concentrations. This paper reports a sensitive and efficient method with automated, on-line clean-up and detection to determine trace estrogens in a small volume of serum samples using liquid chromatography-electrospray ionization-tandem mass spectrometry directly, without off-line liquid-liquid or solid-phase extraction pretreatments. Serum aliquots (charcoal stripped fetal bovine serum, 100 μL) were spiked with four estrogen standards and their corresponding isotope-labeled internal standards, then bulk derivatized with 2-fluoro-1-methyl-pyridium p-toluenesulfonate (2-FMP) to establish the calibration curves and perform method validation. Calibration was established in the concentration ranges of 5-1000 pg mL(-1), and demonstrated good linearity of R(2) from 0.9944 to 0.9997 for the four derivatized estrogens. The lower detection limits obtained were 3-7 pg mL(-1). Good accuracy and precision in the range of 86-112% and 2.3-11.9%, respectively, were observed for the quality control (QC) samples at low, medium, and high concentration levels. The stability tests showed that the derivatized serum samples were stable 8h after derivatization at room temperature and at least to 48 h if stored at -20 °C. The method was applied to measure trace estrogens in real human and bovine serum samples, and three of four estrogen compounds studied were observed and quantified.

MATERIALES
Número de producto
Marca
Descripción del producto

Sigma-Aldrich
Metanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Bicarbonato de sodio, ACS reagent, ≥99.7%
Sigma-Aldrich
Metanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Bicarbonato de sodio, powder, BioReagent, Molecular Biology, suitable for cell culture, suitable for insect cell culture
Sigma-Aldrich
Bicarbonato de sodio, ReagentPlus®, ≥99.5%, powder
Sigma-Aldrich
Metanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Metanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Bicarbonato de sodio, anhydrous, free-flowing, Redi-Dri, ACS reagent, ≥99.7%
Sigma-Aldrich
Bicarbonato de sodio, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, E500, 99.0-100.5%, powder
Sigma-Aldrich
Metanol, Absolute - Acetone free
USP
Metanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Metanol, BioReagent, ≥99.93%
Supelco
Metanol, analytical standard
Supelco
Metanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Bicarbonato de sodio, BioXtra, 99.5-100.5%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
USP
Bicarbonato de sodio, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Bicarbonato de sodio, anhydrous, free-flowing, Redi-Dri, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Bicarbonato de sodio, −40-+140 mesh, ≥95%
Sigma-Aldrich
Bicarbonato de sodio, tested according to Ph. Eur.
Sigma-Aldrich
Sodium bicarbonate-12C, 99.9 atom % 12C
Sigma-Aldrich
Metanol, suitable for NMR (reference standard)