• Inicio
  • Resultados de la búsqueda
  • Determination of trace amounts of zirconium in real samples after microwave digestion and ternary complex dispersive liquid-liquid microextraction.

Determination of trace amounts of zirconium in real samples after microwave digestion and ternary complex dispersive liquid-liquid microextraction.

Environmental monitoring and assessment (2014-02-04)
Daryoush Afzali, Fariba Fathirad, Sima Ghaseminezhad, Zahra Afzali
RESUMEN

In this study, a ternary Zr(IV) system with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) and fluoride was chosen on the basis of dispersive liquid-liquid microextraction method. Zirconium was extracted into the fine droplets of dichlorobenzene as extracting solvent. These drops dispersed as a cloud in the aqueous sample with the help of ultrasonic waves, and the procedure was done. Finally, atomic absorption spectrometry was applied for the determination of zirconium. The effects of different factors that influence complex formation and extraction, such as pH, amounts of complexing agents, type and volume of the extracting solvent, as well as sonication and centrifuging time, were optimized. Under optimum conditions, the calibration curve was linear in the range of 150.0-800.0 ng mL(-1) with a limit of detection of 44.0 ng mL(-1). Relative standard deviation was calculated to be 4.1 % (n = 7, c = 400.0 ng mL(-1)). The enrichment factor was 80. The proposed method was successfully used to determine the zirconium in several water, wastewater, and soil samples.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Zirconium, powder, −100 mesh
Sigma-Aldrich
Zirconium, foil, thickness 0.1 mm, 99.98% trace metals basis
Sigma-Aldrich
Zirconium, sponge, ≥99% trace metals basis
Sigma-Aldrich
Zirconium, rod, diam. 6.35 mm, ≥99% trace metals basis
Zirconium, rod, 100mm, diameter 50mm, centerless ground, 99.2%
Sigma-Aldrich
Zirconium, powder, in water, -325 mesh, 99.5% trace metals basis (excluding Hf)
Zirconium, foil, not light tested, 50x50mm, thickness 0.006mm, 99.2%
Zirconium, rod, 1000mm, diameter 1.5mm, 99.2%
Zirconium, rod, 1000mm, diameter 12.7mm, centerless ground, 99.2%
Zirconium, rod, 1000mm, diameter 2.0mm, centerless ground, 99.2%
Zirconium, rod, 1000mm, diameter 3.0mm, centerless ground, 99.2%
Zirconium, rod, 1000mm, diameter 5.0mm, centerless ground, 99.2%
Zirconium, rod, 1000mm, diameter 6.0mm, centerless ground, 99.2%
Zirconium, rod, 1000mm, diameter 9.5mm, centerless ground, 99.2%
Zirconium, rod, 100mm, diameter 1.5mm, 99.2%
Zirconium, rod, 100mm, diameter 12.7mm, centerless ground, 99.2%
Zirconium, rod, 100mm, diameter 19.0mm, centerless ground, 99.2%
Zirconium, rod, 100mm, diameter 2.0mm, centerless ground, 99.2%
Zirconium, rod, 100mm, diameter 3.0mm, centerless ground, 99.2%
Zirconium, rod, 100mm, diameter 5.0mm, centerless ground, 99.2%
Zirconium, rod, 100mm, diameter 6.0mm, centerless ground, 99.2%
Zirconium, rod, 100mm, diameter 9.5mm, centerless ground, 99.2%
Zirconium, rod, 200mm, diameter 1.5mm, 99.2%
Zirconium, rod, 200mm, diameter 12.7mm, centerless ground, 99.2%
Zirconium, rod, 200mm, diameter 19.0mm, centerless ground, 99.2%
Zirconium, rod, 200mm, diameter 2.0mm, centerless ground, 99.2%
Zirconium, rod, 200mm, diameter 3.0mm, centerless ground, 99.2%
Zirconium, rod, 200mm, diameter 5.0mm, centerless ground, 99.2%
Zirconium, rod, 200mm, diameter 6.0mm, centerless ground, 99.2%
Zirconium, rod, 200mm, diameter 9.5mm, centerless ground, 99.2%

Redes sociales

LinkedIn icon
Twitter icon
Facebook Icon
Instagram Icon

Merck

Investigación. Desarrollo. Producción.

Somos un proveedor líder para la industria de Ciencias de la Vida con soluciones y servicios para investigación, desarrollo y producción biotecnológicos, y para desarrollo y producción de tratamientos farmacéuticos

© 2021 Merck KGaA, Darmstadt, Alemania y/o sus filiales. Todos los derechos reservados.

Queda estrictamente prohibida la reproducción sin permiso de cualquiera de los materiales de la página web.