Skip to Content
Merck

Skip To

UFC5100

Amicon® Ultra Centrifugal Filter, 100 kDa MWCO

greener alternative

sample volume 0.5 mL, regenerated cellulose membrane, MWCO 100 kDa

Amicon® Ultra Centrifugal Filter, 100 kDa MWCO
1 of 2 reviewers received a sample product or took part in a promotion

Synonym(s):

Centrifugal concentrator, 100 kDa MWCO, 0.5 mL sample volume

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice
24 pkg
Check Cart for Availability
PLN 589.00
96 pkg
Check Cart for Availability
PLN 2,000.00
500 pkg
Check Cart for Availability
PLN 8,580.00

About This Item

UNSPSC Code:
41104916
NACRES:
NB.24
eCl@ss:
36100101
Material:
polypropylene cap, polypropylene tube, regenerated cellulose membrane, styrene-butadiene housing
Pore size:
100 kDa MWCO
Working volume:
≤500 μL , 0.5 mL
Sterility:
non-sterile
Packaging:
pkg of 24 pkg, pkg of 500 pkg, pkg of 8 pkg, pkg of 96 pkg

PLN 589.00


Check Cart for Availability

Request a Bulk Order
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Level

material

polypropylene cap, polypropylene tube, regenerated cellulose membrane, styrene-butadiene housing

sterility

non-sterile

product line

Amicon®

packaging

pkg of 24 pkg, pkg of 500 pkg, pkg of 8 pkg, pkg of 96 pkg

manufacturer/tradename

Amicon® Ultra

sustainability

Greener Alternative Product

parameter

0.5 mL sample volume

technique(s)

protein extraction: suitable, protein purification: suitable

L

4.99 cm (1.96 in.)

diam.

10.8 mm

filtration area

1 cm2

volume

0.5 mL

working volume

≤500 μL , 0.5 mL

pore size

100 kDa MWCO

greener alternative category

shipped in

ambient

General description

Amicon® Ultra-0.5 centrifugal filter devices provide fast ultrafiltration, with the capability for high concentration factors and easy concentrate recovery from dilute and complex sample matrices. For example, IgG (156 kDa) at 1 mg/ml initial concentration is typically retained at >95% .

The vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 30-fold concentration. Solute polarization and subsequent fouling of the membrane are minimized by the vertical design, and a physical deadstop in the filter device prevents spinning to dryness and potential sample loss. Efficient recovery of the concentrated sample (retained species) is achieved by a convenient reverse spin step after collecting the filtrate.

Amicon® Ultra-0.5 devices are supplied non-sterile and are for single use only. With their vertical membrane design and reverse spin, Amicon® Ultra 0.5 mL filters deliver great performance and lower spin times.
We are committed to bringing you Greener Alternative Products, which have been re-engineered to enable more sustainable research solutions. The inner filtration device is made from bio-circular material allocated using the ISCC mass balance approach. Click here for more information.

Application

  • Ultrafiltration with 100,000 Dalton molecular weight cutoff Ultracel® membrane
  • Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms
  • Purification of macromolecular components found in tissue culture extracts or cell lysates, primer removal, linkers, or macromolecular labels from a reaction mix, and protein removal prior to HPLC
  • Desalting, buffer exchange, and protein dialysis

Features and Benefits

  • Ultracel® regenerated cellulose membrane with 100 kDa NMWCO delivers retentate recovery of greater than 90%
  • Concentrates 500 μL down to 15 μL
  • Concentration factor 25x to 30x
  • High sample recovery (greater than 90% of dilute starting solution)
  • Fast processing time: 10 to 30 minutes
  • Reverse spin capability provides consistent recoveries

Physical form

Color Code: Clear

Other Notes

Replaces: 42414

Legal Information

Amicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
UFC210024UFC8100UFC9100
material

polypropylene cap, regenerated cellulose membrane, polypropylene tube, styrene-butadiene housing

material

polypropylene tube (for collection), regenerated cellulose membrane, styrene-butadiene housing

material

polyethylene cap, polyethylene liner, polypropylene tube, regenerated cellulose membrane, regenerated cellulose support, styrene-butadiene housing

material

polyethylene cap, polyethylene liner, polypropylene tube, regenerated cellulose membrane, regenerated cellulose support, styrene-butadiene housing

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

pore size

100 kDa MWCO

pore size

100 kDa MWCO

pore size

100 kDa MWCO

pore size

100 kDa MWCO

parameter

0.5 mL sample volume

parameter

2 mL sample volume

parameter

4 mL sample volume

parameter

15 mL sample volume

manufacturer/tradename

Amicon® Ultra

manufacturer/tradename

Amicon® Ultra

manufacturer/tradename

Amicon® Ultra

manufacturer/tradename

Amicon® Ultra

working volume

≤500 μL , 0.5 mL

working volume

≤2 mL

working volume

≤4 mL

working volume

≤15 mL


Still not finding the right product?


Storage Class

11 - Combustible Solids



Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Protocols

Detergents are frequently used to solubilize proteins and nucleic acids during purification, but the presence of detergents may interfere with downstream analyses.

If an antibody must be purified from a small sample volume (0.5-10 mL), then the Amicon® Pro Purification System is recommended.

Articles

Metody filtracji i wybór filtrów membranowych w oczyszczaniu i produkcji nanocząstek.

Poznaj zasady działania membran ultrafiltracyjnych i korzyści związane z przygotowywaniem próbek białek, w tym z wymianą rozpuszczalników i zatężaniem próbek.

Explore ultrafiltration membrane principles and benefits for protein sample preparation, including solvent exchange and sample concentration.

View All Articles

Related Content

Skoncentruj białko, nie trać go. Niezawodne odzyskiwanie białka podczas koncentrowania przy użyciu filtrów Amicon® Ultra.





Global Trade Item Number

SKUGTIN
UFC51002404053252360510
UFC5100BK04053252356872
UFC51000804053252614989
UFC51009608436037126178

Questions

1–5 of 5 Questions  
  1. What is the maximal centrifugal g-level that it can endure?

    1 answer
    1. Amicon Ultra-0.5 devices can tolerate a maximum relative centrifugal force of 15,000 × g.

      Helpful?

  2. Can I sterilize the Amicon® Ultra Centrifugal Filter, 100 kDa MWCO by autoclave before I use it?

    1 answer
    1. There are no validated sterilization methods for the Amicon Ultra devices; however, they can be "sanitized" by performing a spin cycle with 70% ethanol, followed by two rinsing spins with sterile water. It is recommended to filter the concentrated sample using a sterile 0.2 µm syringe filter (e.g., SLGVR33RS) after processing on the Amicon devices.

      Helpful?

  3. Can I reuse Amicon® Ultra Centrifugal Filter, 100 kDa MWCO? ?

    1 answer
    1. This product is intended for single use. Repeated usage may result in declining performance.

      Helpful?

  4. Que signifie le conditionnement de "8 pkg"? Cela correspond-il à 8 eppendorfs/filtres ?

    1 answer
    1. Yes, "8 pkg" means a package of 8 Amicon® Ultra Centrifugal Filters.

      Helpful?

  5. Is dimethylformamide chemically compatible with Amicon Ultra-0.5mL?

    1 answer
    1. No data is presently available for compatibility with dimethylformamide.

      Helpful?

Reviews

Active Filters

  1. 2 Ratings-only reviews