Przejdź do zawartości
Merck

1.50400

Chromolith® CapRod HighResolution RP-8 endcapped (monolithic) HPLC Columns

L × I.D. 150 mm x 0.1 mm Capillary Column

Synonim(y):

Chromolith® CapRod RP-8 endcapped HR 150-0.1 capillary column

Wybierz wielkość

Zmień widok

Informacje o tej pozycji

UNSPSC Code:
41115709
NACRES:
SB.52
eCl@ss:
32110501
Matrix active group:
C8 (RP8), C8 bonding phase
Pore size:
13 nm mesoporosity, 2 μm macroporosity
Matrix:
monolithic silica
Zaloguj się – aby sprawdzić ceny
Pomoc techniczna
Potrzebujesz pomocy? Nasz zespół doświadczonych naukowców chętnie Ci pomoże.
Pozwól nam pomóc


Nazwa produktu

Chromolith® CapRod RP-8 endcapped Capillary Columns, L × I.D. 150 mm x 0.1 mm capillary column

Quality Segment

material

fused silica (capillary column)

agency

suitable for USP L7

product line

Chromolith®

feature

endcapped

analyte functional class(es)

antibiotics, fat soluble vitamins, lipids, nutraceuticals and antioxidants, oils, pigments

analyte chemical class(es)

PCBs (aroclor identification), PFAS, aflatoxins, alcohols and aldehyde, alkaloids, amino acids, cannabinoids as tms derivatives, carotenoids, coloring compounds, essential oils, esters, fatty acids, flavonoids, ketones, metabolized steroids, nitrosamines, nucleosides, oligonucleotides, peptides, pesticides, phenols, phospholipids, phthalate esters, preservatives, proteins, steroids (cholesteryl esters), sulfonamides

packaging

pkg of 3 ea

manufacturer/tradename

Millipore

extent of labeling

11% Carbon loading

parameter

200 bar pressure

technique(s)

HPLC: suitable, LC/MS: suitable (Capillary LC), mass spectrometry (MS): suitable (High)

column L × I.D.

15 cm × 0.1 mm

matrix

monolithic silica

matrix active group

C8 (RP8), C8 bonding phase

pore size

13 nm mesoporosity, 2 μm macroporosity

operating pH range

2-7.5

separation technique

reversed phase

storage temp.

no temp limit

General description

A Chromolith® CapRod capillary column combines the speed of monolithic silica technology with the sensitivity of nano-LC. This enables superior productivity for high throughput, highly sensitive proteomics-LC applications.
Compared to particulate capillary columns, Chromolith® CapRod capillaries demonstrate better performance with optimal resolution (narrow peak widths), increased productivity (higher sample throughput), and extended column lifetime. Furthermore, column length is less limited than with any other type of column. The capillaries can even be slightly bent to fit any LC configuration or instrument.
Chromolith® CapRod columns are designed to work with various nano or capillary-LC systems. This provides the highest efficiency and performance when coupled to mass spectrometers, both on-line (ESI, nanospray) and off-line (MALDI).

Why choose Chromolith® CapRod capillary columns?
—Higher flow rates than particle-packed capillary columns
—Columns at low pressure
—Long column lifetime
—Robust and easy handling
—Flow rates from 0.1–200 μL/min ensure ideal compatibility with LC/MS systems, with both ESI and APCI interfaces

Chromolith® CapRod RP-8 endcapped can be operated at significantly higher flow rates without loss of performance. The typical flow rate for this 150-0.1 capillary column ranges from 0.4 μL/min to 3 μL/min.

Learn more:
Brochure: Race through your Separations on Any System. Chromolith® Monolithic Silica HPLC Columns

Legal Information

Chromolith is a registered trademark of Merck KGaA, Darmstadt, Germany
Ta strona może zawierać tekst przetłumaczony maszynowo.




Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

Nie widzisz odpowiedniej wersji?

Jeśli potrzebujesz konkretnej wersji, możesz wyszukać konkretny certyfikat według numeru partii lub serii.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów