650447
HPLC Plus
for residue analysis
2.1 (vs air)
33 mmHg ( 20 °C)
44 mmHg ( 25 °C)
99.9%
liquid
750 °F
2.0-12.7 %, 93 °C
HPLC: suitable
gas chromatography (GC): suitable
≤0.02% water
≤0.5 ppb Fluorescence (quinine) (365 nm)
≤0.0001%
≤10 ng/L (as heptachlor epoxide)
n20/D 1.377 (lit.)
7.0 (20 °C)
82 °C (lit.)
−89.5 °C (lit.)
water: soluble
0.785 g/mL at 25 °C (lit.)
H2O reference
λ: 245 nm Amax: ≤1.0
λ: 250 nm Amax: ≤0.30
λ: 275-400 nm Amax: ≤0.005
food and beverages
CC(C)O
1S/C3H8O/c1-3(2)4/h3-4H,1-2H3
KFZMGEQAYNKOFK-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
Danger
Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 3
Central nervous system
3 - Flammable liquids
WGK 1
53.6 °F - closed cup
12.0 °C - closed cup
Enter Lot Number to search for Certificate of Analysis (COA).
Enter Lot Number to search for Certificate of Origin (COO).
This page provides tables that list the products used in promulgated methods for Per- and polyfluoroalkyl substances (PFAS) analysis, organized by method and step for easy reference. As new methods are released, this page will be updated.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service