Evaluation of the full evaporation technique for quantitative analysis of high boiling compounds with high affinity for apolar matrices.

Journal of chromatography. A (2014-05-17)
Niels van Boxtel, Kris Wolfs, Ann van Schepdael, Erwin Adams
RESUMEN

In order to reduce inaccuracies due to possible matrix effects in conventional static headspace-gas chromatography (sHS-GC), it is standard practice to match the composition of calibration standards towards the composition of the sample to be analysed by adding blank matrix. However, the latter is not always available and in that case the full evaporation technique (FET) could be a solution. With FET a small sample volume is introduced in a HS vial and compounds of interest are completely evaporated. Hence no equilibrium between the condensed phase and vapour phase exists. Without the existence of an equilibrium, matrix effects are less likely to occur. Another issue often encountered with sHS-sampling is that low vapour pressure compounds with a high affinity for the dilution medium show a limited sensitivity. FET has proven to be an appropriate solution to address this problem too. In this work, the applicability of FET for the quantitative analysis of high boiling compounds in different complex apolar matrices is examined. Data show that FET is an excellent tool to overcome matrix effects often encountered with conventional sHS analysis. The tested method shows excellent accuracy with recovery values around 100% as well as repeatability with RSD values around 1% for the quantification of high boiling compounds (bp>200°C) such as camphor, menthol, methyl salicylate and ethyl salicylate in various matrices. LOQ values were found to be around 0.3μg per vial. Following validation of the technique, several topical pharmaceutical formulations like ThermoCream(®), Reflexspray(®), Vicks Vaporub(®) and Radosalil(®) were examined. For the latter, a comparison has been made with a sHS-method described in literature.

MATERIALES
Número de producto
Marca
Descripción del producto

Sigma-Aldrich
o-Xylene, puriss. p.a., ≥99.0% (GC)
Sigma-Aldrich
1-Octanol, ACS reagent, ≥99%
Sigma-Aldrich
Dodecane, ReagentPlus®, ≥99%
Sigma-Aldrich
o-Xylene, reagent grade, ≥98.0%
Sigma-Aldrich
1-Octanol, suitable for HPLC, ≥99%
Sigma-Aldrich
1-Octanol, ReagentPlus®, 99%
Sigma-Aldrich
Dodecane, anhydrous, ≥99%
Supelco
o-Xylene, suitable for HPLC, 98%
Sigma-Aldrich
o-Xylene, anhydrous, 97%
Sigma-Aldrich
1-Octanol, anhydrous, ≥99%
Supelco
Dodecane, analytical standard
Supelco
o-Xylene, analytical standard
Sigma-Aldrich
1-Octanol, ≥98%, FCC, FG
Supelco
1-Octanol, analytical standard
Supelco
o-Xylene, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
1-Octanol, natural, ≥98%, FCC
Supelco
Density Standard 750 kg/m3, H&D Fitzgerald Ltd. Quality
Sigma-Aldrich
o-Xylene, SAJ special grade, ≥98.5%
Sigma-Aldrich
1-Octanol, JIS special grade, ≥98.0%
Sigma-Aldrich
1-Octanol, SAJ first grade, ≥75.0%