Saltar al contenido
MilliporeSigma
Get up to 22% off for Pi Day until 3/26.Save Now
  • Deficit in sustained attention following selective cholinergic lesion of the pedunculopontine tegmental nucleus in rat, as measured with both post-mortem immunocytochemistry and in vivo PET imaging with [¹⁸F]fluoroethoxybenzovesamicol.

Deficit in sustained attention following selective cholinergic lesion of the pedunculopontine tegmental nucleus in rat, as measured with both post-mortem immunocytochemistry and in vivo PET imaging with [¹⁸F]fluoroethoxybenzovesamicol.

Behavioural brain research (2014-09-27)
Marilyn Cyr, Maxime J Parent, Naguib Mechawar, Pedro Rosa-Neto, Jean-Paul Soucy, Stewart D Clark, Meghmik Aghourian, Marc-Andre Bedard
RESUMEN

Cholinergic neurons of the pedunculopontine tegmental nucleus (PPTg) are thought to be involved in cognitive functions such as sustained attention, and lesions of these cells have been documented in patients showing fluctuations of attention such as in Parkinson's disease or dementia with Lewy Body. Animal studies have been conducted to support the role of these cells in attention, but the lesions induced in these animals were not specific to the cholinergic PPTg system, and were assessed by post-mortem methods remotely performed from the in vivo behavioral assessments. Moreover, sustained attention have not been directly assessed in these studies, but rather deduced from indirect measurements. In the present study, rats were assessed on the 5-Choice Serial Reaction Time Task (5-CSRTT), and a specific measure of variability in response latency was created. Animals were observed both before and after selective lesion of the PPTg cholinergic neurons. Brain cholinergic denervation was assessed both in vivo and ex vivo, using PET imaging with [(18)F]fluoroethoxybenzovesamicol ([(18)F]FEOBV) and immunocytochemistry respectively. Results showed that the number of correct responses and variability in response latency in the 5-CSRTT were the only behavioral measures affected following the lesions. These measures were found to correlate significantly with the number of PPTg cholinergic cells, as measured with both [(18)F]FEOBV and immunocytochemistry. This suggests the primary role of the PPTg cholinergic cells in sustained attention. It also allows to reliably use the PET imaging with [(18)F]FEOBV for the purpose of assessing the relationship between behavior and cholinergic innervation in living animals.

MATERIALES
Número de producto
Marca
Descripción del producto

Sigma-Aldrich
Alcohol etílico puro 200, Molecular Biology
Sigma-Aldrich
Alcohol etílico puro, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Alcohol etílico puro, 200 proof
Sigma-Aldrich
Alcohol etílico puro, 200 proof, meets USP testing specifications
Sigma-Aldrich
Alcohol etílico puro, 200 proof, anhydrous, ≥99.5%
Sigma-Aldrich
Alcohol etílico puro 190, for molecular biology
Sigma-Aldrich
o-Xylene, puriss. p.a., ≥99.0% (GC)
Sigma-Aldrich
Alcohol etílico puro, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
o-Xylene, reagent grade, ≥98.0%
Supelco
Etanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Alcohol etílico puro, 190 proof, meets USP testing specifications
Supelco
o-Xylene, suitable for HPLC, 98%
Sigma-Aldrich
o-Xylene, anhydrous, 97%
Sigma-Aldrich
Etanol, puriss. p.a., absolute, ≥99.8% (GC)
Supelco
Ethanol solution, certified reference material, 2000 μg/mL in methanol
Supelco
o-Xylene, analytical standard
Supelco
Ethanol solution, 10 % (v/v) in H2O, analytical standard
Sigma-Aldrich
Etanol, JIS special grade, 94.8-95.8%
USP
Etanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Etanol, ≥99.5%, suitable for HPLC
Sigma-Aldrich
Etanol, ≥99.5%
Sigma-Aldrich
Etanol, ≥99.5%, suitable for absorption spectrum analysis
Supelco
o-Xylene, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Ethanol solution, suitable for fixing solution (blood films)
Sigma-Aldrich
Etanol, 94.8-95.8%
Sigma-Aldrich
Etanol, ≥99.5%, SAJ super special grade
Sigma-Aldrich
Etanol, ≥99.5%, suitable for fluorescence
Sigma-Aldrich
o-Xylene, SAJ special grade, ≥98.5%
Sigma-Aldrich
Etanol, JIS 1000, ≥99.5%, suitable for residue analysis
Sigma-Aldrich
Etanol, JIS 300, ≥99.5%, suitable for residue analysis