Saltar al contenido
MilliporeSigma
Get up to 22% off for Pi Day until 3/26.Save Now

Galectin-3 binding protein links circulating microparticles with electron dense glomerular deposits in lupus nephritis.

Lupus (2015-04-04)
C T Nielsen, O Østergaard, O P Rekvig, G Sturfelt, S Jacobsen, N H H Heegaard
RESUMEN

A high level of galectin-3-binding protein (G3BP) appears to distinguish circulating cell-derived microparticles in systemic lupus erythematosus (SLE). The aim of this study is to characterize the population of G3BP-positive microparticles from SLE patients compared to healthy controls, explore putative clinical correlates, and examine if G3BP is present in immune complex deposits in kidney biopsies from patients with lupus nephritis. Numbers of annexin V-binding and G3BP-exposing plasma microparticles from 56 SLE patients and 36 healthy controls were determined by flow cytometry. Quantitation of microparticle-associated G3BP, C1q and immunoglobulins was obtained by liquid chromatography tandem mass spectrometry (LC-MS/MS). Correlations between microparticle-G3BP data and clinical parameters were analyzed. Co-localization of G3BP with in vivo-bound IgG was examined in kidney biopsies from one non-SLE control and from patients with class IV (n = 2) and class V (n = 1) lupus nephritis using co-localization immune electron microscopy. Microparticle-G3BP, microparticle-C1q and microparticle-immunoglobulins were significantly (P < 0.01) increased in SLE patients by LC-MS/MS. Three G3BP-exposing microparticle populations could be discerned by flow cytometry, including two subpopulations that were significantly increased in SLE samples (P = 0.01 and P = 0.0002, respectively). No associations of G3BP-positive microparticles with clinical manifestations or disease activity were found. Immune electron microscopy showed co-localization of G3BP with in vivo-bound IgG in glomerular electron dense immune complex deposits in all lupus nephritis biopsies. Both circulating microparticle-G3BP numbers as well as G3BP expression are increased in SLE patients corroborating G3BP being a feature of SLE microparticles. By demonstrating G3BP co-localized with deposited immune complexes in lupus nephritis, the study supports cell-derived microparticles as a major autoantigen source and provides a new understanding of the origin of immune complexes occurring in lupus nephritis.

MATERIALES
Número de producto
Marca
Descripción del producto

Sigma-Aldrich
Metanol, anhydrous, 99.8%
Sigma-Aldrich
Trichloroacetic acid, ACS reagent, ≥99.0%
Sigma-Aldrich
Trichloroacetic acid solution, 6.1 N
Sigma-Aldrich
Metanol, JIS special grade, ≥99.8%
Sigma-Aldrich
Trichloroacetic acid, BioUltra, ≥99.5% (T)
Sigma-Aldrich
Trichloroacetic acid, suitable for electrophoresis, suitable for fixing solution (for IEF and PAGE gels), ≥99%
Sigma-Aldrich
Acetona, JIS special grade, ≥99.5%
Sigma-Aldrich
Trichloroacetic acid, BioXtra, ≥99.0%
Sigma-Aldrich
Trichloroacetic acid, ≥99.0% (titration)
Sigma-Aldrich
2-Isocyanatoethyl methacrylate, contains ≤0.1% BHT as inhibitor, 98%
Sigma-Aldrich
Metanol, SAJ first grade, ≥99.5%
Sigma-Aldrich
Ácido fórmico, ≥95%, FCC, FG
Sigma-Aldrich
Acetona, SAJ first grade, ≥99.0%
Sigma-Aldrich
Metanol, SAJ special grade
Sigma-Aldrich
Acetona, ≥99%, FCC, FG
Sigma-Aldrich
Ácido fórmico, JIS special grade, ≥98.0%
Sigma-Aldrich
Acetona, natural, ≥97%
Sigma-Aldrich
Acetona, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC
Sigma-Aldrich
Trichloroacetic acid, ACS reagent, for the determination of Fe in blood according to Heilmeyer, ≥99.5%
Sigma-Aldrich
Metanol, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, 99.93%
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
Metanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol solution, suitable for NMR (reference standard), 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Acetona, suitable for residue analysis, ≥99.5%
Sigma-Aldrich
Acetona, suitable for HPLC
Sigma-Aldrich
Acetona, ≥99.5%, suitable for residue analysis
Sigma-Aldrich
Metanol, JIS 300, ≥99.8%, suitable for residue analysis
Sigma-Aldrich
Acetona, suitable for chromatography, ≥99.8%