Saltar al contenido
MilliporeSigma
  • Quantification of circulating steroids in individual zebrafish using stacking to achieve nanomolar detection limits with capillary electrophoresis and UV-visible absorbance detection.

Quantification of circulating steroids in individual zebrafish using stacking to achieve nanomolar detection limits with capillary electrophoresis and UV-visible absorbance detection.

Analytical and bioanalytical chemistry (2015-06-05)
Vincent T Nyakubaya, Brandon C Durney, Marriah C G Ellington, Amber D Kantes, Paige A Reed, Shaylyn E Walter, Jennifer Ripley Stueckle, Lisa A Holland
RESUMEN

Capillary electrophoresis and UV-visible absorbance detection are used with sample stacking to achieve detection limits ranging from 0.2 to 2 ng/mL (0.8 to 6 nM) for steroids. Stacking is accomplished using negatively charged cyclodextrin steroid-carrier molecules at a discrete pH interface between the reconstituted sample and the separation electrolyte. Steroids are then separated in under 5 min using capillary electrophoresis that incorporates secondary equilibria via sodium dodecyl sulfate and cyclodextrin. The effectiveness of the method for measurements of multiple steroids in limited sample volumes is demonstrated in individual female fish with total circulating blood volumes of 5 μL or less. Steroid recoveries from plasma following a sample processing method developed with commercial extraction cartridges range from 81 to 109 % for 17α,20β-dihydroxy-pregn-4-en-3-one, testosterone, 11-ketotestosterone, estrone, 17β-estradiol, and 17α-ethinyl estradiol. When applied to reproductively active female zebrafish, changes were detected in the levels of circulating steroids as a result of exposure to different solvents and 17β-estradiol.

MATERIALES
Número de producto
Marca
Descripción del producto

Sigma-Aldrich
Metanol, anhydrous, 99.8%
Sigma-Aldrich
Acetato de etilo, anhydrous, 99.8%
Sigma-Aldrich
Metanol, JIS special grade, ≥99.8%
Sigma-Aldrich
Metanol, SAJ first grade, ≥99.5%
Sigma-Aldrich
Acetato de etilo, ≥99%, FCC, FG
Sigma-Aldrich
Metanol, SAJ special grade
Sigma-Aldrich
Acetato de etilo
Sigma-Aldrich
Acetato de etilo, natural, ≥99%, FCC, FG
Sigma-Aldrich
Metanol, suitable for HPLC
Sigma-Aldrich
Acetato de etilo, ReagentPlus®, ≥99.8%
Sigma-Aldrich
Acetato de etilo, JIS special grade, ≥99.5%
Sigma-Aldrich
Metanol, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, 99.93%
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
Acetato de etilo, ACS reagent, ≥99.5%
Sigma-Aldrich
Metanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol solution, suitable for NMR (reference standard), 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Acetato de etilo, SAJ first grade, ≥99.0%
Sigma-Aldrich
Metanol, JIS 300, ≥99.8%, suitable for residue analysis
Sigma-Aldrich
Acetato de etilo, suitable for HPLC
Sigma-Aldrich
Acetato de etilo, JIS 300, ≥99.5%, suitable for residue analysis
Sigma-Aldrich
Acetato de etilo, JIS 1000, ≥99.5%, suitable for residue analysis