Fortfahren mit
Größe auswählen
| Größe/SKU | Verfügbarkeit | Preis |
|---|---|---|
1 mL | Warenkorb auf Verfügbarkeit prüfen | € 95,30 |
5 mL | Warenkorb auf Verfügbarkeit prüfen | € 452,00 |
10 mL | Warenkorb auf Verfügbarkeit prüfen | € 857,00 |
Über diesen Artikel
€ 95,30
shelf life
≤12 mo.
manufacturer/tradename
Roche
packaging
kit of 1 mL (100 x 20 μL rxn; KK4705), kit of 10 mL (1000 x 20 μL rxn; KK4707), kit of 5 mL (500 x 20 μL rxn; KK4706), kit of 50 mL (5000 x 20 mL rxn; KK4714), pkg of
concentration
2 ×
technique(s)
qPCR: suitable, whole genome amplification: suitable
compatibility
for use with Applied Biosystems® 5700, for use with Applied Biosystems® 7000, for use with Applied Biosystems® 7300, for use with Applied Biosystems® 7700, for use with Applied Biosystems® 7900HT, for use with StepOne™, for use with StepOnePlus™
storage temp.
−20°C
General description
Application
Features and Benefits
- Hervorragende Differenzierung zwischen heterozygoten und homozygoten Allelen
- Diskrete Cluster in SNP-Genotypisierungsassays
Erzielung ausgezeichneter Reproduzierbarkeit und Effizienz:
- Schnelle, leistungsstarke fünffarbige Multiplex-PCR
- Erzielung ähnlicher Abundanzlevel mit niedriger Kopienzahl
- Breiter dynamischer Bereich mit bis zu 10 Größenordnungen
Erhöhte Flexibilität:
- Kompatibel mit Standard- und Schnellzyklusprotokollen, Aufrechterhaltung genauer Quantifizierung
Einige Anmerkungen:
- Diese Kits sind mit allen fluorogenen sondenbasierten Technologien kompatibel, einschließlich Hybridisierungssonden (z. B. FRET), Hydrolysesonden (z. B. TaqMan®) und Verdrängungssonden (z. B. Molecular Beacons).
- Anfängliche Denaturierung von 20 Sekunden bei 95 °C ist für die Aktivierung des Enzyms ausreichend; für eine optimale Denaturierung komplexer Targets können jedoch 3 Minuten erforderlich sein.
- Für einen 2-Schritt-Zyklus sind insgesamt 30 Sekunden für Annealing/Extension/Datenerfassung nötig.
- Für einen 3-Schritt-Zyklus sind 20 Sekunden für das Primer-Annealing und 1 Sekunde für die Extension/Datenerfassung nötig.
- Das Volumen darf 25 μL nicht überschreiten.
- Mit verschiedenen qPCR-Protokollen kompatibel
Preparation Note
KAPA PROBE FAST qPCR Master Mix (2X) ABI PRISM® bleibt über 30 Gefrier-/Auftau-Zyklen hinweg stabil. Stellen Sie bei Nichtgebrauch der Reagenzien sicher, dass diese bei -20 °C vor Lichteinwirkung geschützt gelagert werden. Die Reagenzien sind vor Licht geschützt im Dunkeln bei 4 °C mindestens eine Woche haltbar und können bei dieser Temperatur für den baldigen Gebrauch aufbewahrt werden, solange sie nicht mit Mikroorganismen und/oder Nukleasen kontaminiert werden.
Analysis Note
Other Notes
Legal Information
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| description suitable for qPCR, 2 ×, ABI Prism® | description suitable for qPCR, 2 ×, Universal | description suitable for qPCR, 2 ×, ROX™ Low | description suitable for qPCR, 2 ×, ABI PRISM® |
| technique(s) qPCR: suitable, whole genome amplification: suitable | technique(s) whole genome amplification: suitable, qPCR: suitable | technique(s) qPCR: suitable, whole genome amplification: suitable | technique(s) whole genome amplification: suitable, qPCR: suitable |
| concentration 2 × | concentration 2 × | concentration 2 × | concentration 2 × |
| manufacturer/tradename Roche | manufacturer/tradename Roche | manufacturer/tradename Roche | manufacturer/tradename Roche |
| compatibility for use with StepOne™, for use with Applied Biosystems® 5700, for use with Applied Biosystems® 7900HT, for use with Applied Biosystems® 7300, for use with Applied Biosystems® 7700, for use with Applied Biosystems® 7000, for use with StepOnePlus™ | compatibility for use with StepOne™, for use with Agilent Mx4000, for use with Applied Biosystems® 5700, for use with Applied Biosystems® 7500, for use with Applied Biosystems® ViiA 7, for use with Agilent Mx3000P, for use with Applied Biosystems® 7900HT, for use with Agilent Mx3005P, for use with Applied Biosystems® 7000, for use with StepOnePlus™, for use with QuantStudio™, for use with Applied Biosystems® 7700, for use with Applied Biosystems® 7300 | compatibility for use with Applied Biosystems® 7500, for use with Applied Biosystems® ViiA 7, for use with Agilent Mx4000, for use with Agilent Mx3000P, for use with Agilent Mx3005P, for use with QuantStudio™ | compatibility for use with StepOnePlus™, for use with StepOne™, for use with Applied Biosystems® 7900HT, for use with Applied Biosystems® 7300, for use with Applied Biosystems® 7700, for use with Applied Biosystems® 7000, for use with Applied Biosystems® 5700 |
| shelf life ≤12 mo. | shelf life ≤12 mo. | shelf life ≤12 mo. | shelf life ≤12 mo. |
| storage temp. −20°C | storage temp. −20°C | storage temp. −20°C | storage temp. −20°C |
Still not finding the right product?
Explore all of our products under KAPA PROBE FAST
Nur Kit-Komponenten
- qPCR Master Mix
- ROX™ High incorporated in the reaction mix
- KAPA Taq HotStart® DNA Polymerase
- dNTPs
- MgCl2 5 nM
Lagerklasse
12 - Non Combustible Liquids
Was ist los?
WGK 1
Flammpunkt (°F)
does not flash
Flammpunkt (°C)
does not flash
Hier finden Sie alle aktuellen Versionen:
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.