Direkt zum Inhalt
Merck

74092

Natriumphosphat monobasisch -Lösung

BioUltra, 5 M in H2O

Synonym(e):

Monosodium phosphate solution, Sodium dihydrogen phosphate, Sodium dihydrogen orthophosphate,Sodium orthophosphate monobasic, Dihydrogen monosodium phosphate, Dihydrogen sodium phosphate

Anmelden zur Ansicht der Organisations- und Vertragspreise.

Größe auswählen

100 ML

€ 85,30

500 ML

€ 273,00

€ 85,30


Warenkorb auf Verfügbarkeit prüfen

Großbestellung anfragen

Über diesen Artikel

Empirische Formel (Hill-System):
H2NaO4P
CAS-Nummer:
Molekulargewicht:
119.98
UNSPSC Code:
12161700
NACRES:
NA.25
PubChem Substance ID:
MDL number:
Beilstein/REAXYS Number:
3903772

Fortfahren mit

Technischer Dienst
Benötigen Sie Hilfe? Unser Team von erfahrenen Wissenschaftlern ist für Sie da.
Unterstützung erhalten

Produktname

Natriumphosphat monobasisch -Lösung, BioUltra, 5 M in H2O

InChI

1S/Na.H3O4P/c;1-5(2,3)4/h;(H3,1,2,3,4)/q+1;/p-1

SMILES string

[Na+].OP(O)([O-])=O

InChI key

AJPJDKMHJJGVTQ-UHFFFAOYSA-M

product line

BioUltra

form

liquid

concentration

5 M in H2O

impurities

insoluble matter, passes filter test
≤0.001% total nitrogen (N)

pH

3.0-4.5 (25 °C, 5 M in H2O)

solubility

H2O: 5 M, clear, colorless

density

1.40 g/mL at 20 °C

anion traces

chloride (Cl-): ≤5 mg/kg
sulfate (SO42-): ≤30 mg/kg

cation traces

Al: ≤1 mg/kg
As: ≤0.1 mg/kg
Ba: ≤1 mg/kg
Bi: ≤1 mg/kg
Ca: ≤5 mg/kg
Cd: ≤1 mg/kg
Co: ≤1 mg/kg
Cr: ≤1 mg/kg
Cu: ≤1 mg/kg
Fe: ≤1 mg/kg
K: ≤20 mg/kg
Li: ≤1 mg/kg
Mg: ≤1 mg/kg
Mn: ≤1 mg/kg
Mo: ≤1 mg/kg
Ni: ≤1 mg/kg
Pb: ≤1 mg/kg
Sr: ≤1 mg/kg
Zn: ≤1 mg/kg

λ

1 M in H2O

UV absorption

λ: 260 nm Amax: ≤0.025
λ: 280 nm Amax: ≤0.02

application(s)

diagnostic assay manufacturing

Quality Level

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Ähnliche Artikel vergleichen

Vollständigen Vergleich anzeigen

Unterschiede anzeigen

1 of 4

Dieser Artikel
S313971496S0751
concentration

5 M in H2O

concentration

-

concentration

-

concentration

-

product line

BioUltra

product line

BioReagent

product line

-

product line

ReagentPlus®

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

200

application(s)

diagnostic assay manufacturing

application(s)

diagnostic assay manufacturing

application(s)

sample preparation

application(s)

detection

form

liquid

form

solid

form

crystals

form

powder or crystals

pH

3.0-4.5 (25 °C, 5 M in H2O)

pH

4.0-4.5 (25 °C, 50 g/L in water)

pH

4.0-4.5 (25 °C, 50 mg/mL in H2O)

pH

4.0-4.5 (25 °C, 50 g/L in water)

Application

Sodium phosphate monobasic solution has been used as a component of aCSF (artificial cerebrospinal fluid) stock solution for use in the patch-seq analysis of small interneurons.[1] It has also been used as a supplement in the preparation of crude extract of cells for decentralizing cell-free RNA sensing.[2]

General description

Sodium phosphate monobasic serves as a source of phosphate ions.[3] The use of sodium phosphate monobasic to correct severe hypophosphatemia conditions has been reviewed.

Lagerklasse

10 - Combustible liquids

wgk

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Decentralizing Cell-Free RNA Sensing With the Use of Low-Cost Cell Extracts
Arce A, et al.
Frontiers in Bioengineering and Biotechnology (2021)
Phosphorus availability from inorganic phosphorus sources in yellowtail (Seriola quinqueradiata Temminck and Schlegel)
Sarker PK, et al.
Aquaculture (Amsterdam, Netherlands) (2009)
Marcela Lipovsek et al.
STAR protocols, 1(3), 100146-100146 (2020-12-31)
Obtaining electrophysiological recordings and gene expression information from the same neuron (Patch-seq) brings forward a unique opportunity to study the transcriptional correlates of functional properties and vice versa. Here, we provide a detailed Patch-seq protocol tailored to the specialized demands
Samuel Adler et al.
Gastrointestinal endoscopy, 76(6), 1170-1174 (2012-10-03)
Colon capsule endoscopy (CCE) is a noninvasive technique for the detection of colorectal lesions. However, for CCE to be offered as an out-of-clinic procedure, the system needs to automatically alert the patient when to ingest the laxative (booster). We tested
Charles W Kimbrough et al.
Clinical cancer research : an official journal of the American Association for Cancer Research, 21(20), 4576-4585 (2015-07-01)
pH-low insertion peptides (pHLIP) can serve as a targeting moiety that enables pH-sensitive probes to detect solid tumors. Using these probes in conjunction with multispectral optoacoustic tomography (MSOT) is a promising approach to improve imaging for pancreatic cancer. A pH-sensitive

Protokolle

To measure alcohol dehydrogenase activity, this assay uses β-nicotinamide adenine dinucleotide phosphate and a continuous spectrophotometric rate determination at 340 nm.

To measure hyaluronidase activity, a turbidimetric determination assay is used at 600 nm. One unit of hyaluronidase activity will cause a change in absorbance of 0.330 per minute at pH 5.35 at 37 °C.

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. What's the pH of this solution?

    1 answer
    1. The pH of this solution may range from 3.0 to 4.5. This value is lot-specific and reported in the Certificate of Analysis. Please see the link below to review a sample or lot-specific certificate:
      https://www.sigmaaldrich.com/product/sigma/74092#product-documentation

      Helpful?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung