  • Validation of a liquid chromatography-high-resolution mass spectrometry method for the analysis of ceftiofur in poultry muscle, kidneys and plasma: A unique accuracy profile for each and every matrix.

Validation of a liquid chromatography-high-resolution mass spectrometry method for the analysis of ceftiofur in poultry muscle, kidneys and plasma: A unique accuracy profile for each and every matrix.

Journal of chromatography. A (2015-07-15)
Sophie Mompelat, Marie-Pierre Fourmond, Michel Laurentie, Eric Verdon, Dominique Hurtaud-Pessel, Jean-Pierre Abjean
ZUSAMMENFASSUNG

A robust, selective and specific liquid chromatography-high resolution mass spectrometry (LC-HRMS) method was developed for the quantification of total residues of ceftiofur, an antibiotic belonging to the 3rd generation cephalosporins in plasma, muscle and kidney of poultry. Ceftiofur and conjugates in samples were firstly hydrolyzed with dithioerythritol into desfuroylceftiofur, which was then stabilized by derivatization with iodoacetamide into desfuroylceftiofur acetamide. Sample were then submitted to a solid phase extraction followed the accurate mass analysis of desfuroylceftiofur acetamide by LC-HRMS in full scan mode using a linear trap quadrupole (LTQ)-Orbitrap mass spectrometer with a resolving power 60,000 full width at half maximum (FWHM). The method was fully validated over a dosing range between 100 and 2000 μg kg(-1) (or μg L(-1)) using the total error approach. Accuracy profiles a graphical decision-making tool were built by computing results of validation procedure with acceptance limits set at ±60%, and β-expectation tolerance intervals, i.e. the interval assuming to contain a β % of future measurements (β=90% in this study). Total measurement error including trueness, repeatability and intermediate precision were evaluated. Relative bias of trueness was never exceeding the threshold of 6% in all matrices at all level of concentration. The mean relative standard deviation for repeatability was lower than 16% at all levels of concentration for all matrices; the mean relative standard deviation for intermediate precision was lower than 25% at all levels of concentration for all matrices. This validation approach proved that the method is reliable for the quantification in each and every matrix (i.e. plasma, kidneys and muscle of chicken) thanks to only one single regression model (i.e. linear) obtained from external calibration standards (without matrix) with deuterated labelled internal standard. The developed method was applied during a depletion study of ceftiofur in chicken tissues and plasma.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Acetonitril, anhydrous, 99.8%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Natronlauge, BioUltra, Molecular Biology, 10 M in H2O
Sigma-Aldrich
Jodacetamid, BioUltra
Sigma-Aldrich
Jodacetamid, Single use vial of 56 mg
Sigma-Aldrich
Natronlauge, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Salzsäure -Lösung, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Perfluorbuttersäure, 98%
Sigma-Aldrich
Jodacetamid, ≥99% (NMR), crystalline
Sigma-Aldrich
Ammoniumacetat, Molecular Biology, ≥98%
Sigma-Aldrich
Salzsäure, 36.5-38.0%, BioReagent, Molecular Biology
Supelco
Salzsäure -Lösung, volumetric, 0.1 M HCl (0.1N), endotoxin free
Sigma-Aldrich
Ammoniumacetat -Lösung, Molecular Biology, 7.5 M
Sigma-Aldrich
Ammoniak, anhydrous, ≥99.98%
Sigma-Aldrich
Ammoniumacetat, 99.999% trace metals basis
Sigma-Aldrich
Ammoniak -Lösung, 4 M in methanol
Sigma-Aldrich
Salzsäure -Lösung, ~6 M in H2O, for amino acid analysis
Sigma-Aldrich
Ammoniak -Lösung, 0.4 M in THF
Sigma-Aldrich
Chlorwasserstoff, ReagentPlus®, ≥99%
Sigma-Aldrich
Acetonitril, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Ammoniumacetat, reagent grade, ≥98%
Sigma-Aldrich
2,2,4-Trimethylpentan, anhydrous, 99.8%
Sigma-Aldrich
Ammoniumacetat, BioXtra, ≥98%
Sigma-Aldrich
Chlorwasserstoff -Lösung, 3 M in cyclopentyl methyl ether (CPME)
Sigma-Aldrich
Natriumhydroxid, BioUltra, suitable for luminescence, ≥98.0% (T), pellets
Sigma-Aldrich
Heptafluorbuttersäure, ≥99.0% (GC)
Sigma-Aldrich
Salzsäure -Lösung, 32 wt. % in H2O, FCC
Sigma-Aldrich
Natriumhydroxid, ultra dry, powder or crystals, 99.99% trace metals basis
Sigma-Aldrich
1,4-Dithioerythritol, ≥99.0%
SAFC
Jodacetamid