Direkt zum Inhalt
Merck

GC Analysis of Polynuclear Aromatic Hydrocarbons (PAHs) in Butter on SLB®-35ms after SPE using Supelclean EZ-POP NP

GC Analysis of Polynuclear Aromatic Hydrocarbons (PAHs) in Butter on SLB®-35ms after SPE using Supelclean™ EZ-POP NP suitable for GC, application for SPE

Materialien

used together

Produkt-Nr.
Beschreibung
Preisangaben

Supelclean LC-Si SPE-Röhrchen

bed wt. 500 mg, volume 3 mL, pk of 54

Supelclean EZ-POP NP

volume 12 mL, pkg of 20

Ähnliches Produkt

Produkt-Nr.
Beschreibung
Preisangaben

Perylen-d12 -Lösung

certified reference material, 2000 μg/mL in dichloromethane

Acenaphthen-d10 -Lösung

certified reference material, 2000 μg/mL in dichloromethane

Naphthalin-d8 -Lösung

certified reference material, 2000 μg/mL in dichloromethane

Inlet-Liner, Split/Splitless-Typ, sich verjüngendes Fast FocusLiner Design (mit Wolle gepackt)

pkg of 1 ea

CONDITIONS

sample preparation

SPE (Solid Phase Extraction)

sample/matrix

butter

SPE tube/cartridge

Supelclean EZ-POP NP, 2.5 g/12 mL (54341-U)

extraction process

0.5 gm melted butter, diluted to 1 mL in cyclohexane

condition

10 mL acetone, dry 10 min at -10 to -15" Hg

sample addition

0.5 mL butter in cyclohexane

elution

2 x 10 mL acetonitrile

eluate post-treatment

add 5 mL water to eluant, and backextract with 2 x 10 mL aliquots of hexane. concentrate hexane extract to 1 mL

sample preparation

Supelclean LC-Si, 500 mg/3 mL, condition: 3 mL acetone, dry 10 min; then 6 mL hexane, load: concentrated hexane extract, elute: 10 mL hexane, concentrate extract to 1 mL

column

SLB-35ms, 30 m x 0.25 mm I.D., 0.25 μm (29804-U)

oven

60°C (1 min), 20 °C/min to 340°C (10 min)

inj. temp.

300 °C

detector

MSD-SIM (MS source temp.: 250°, MS quads temp.: 200°C)

MSD interface

330 °C

scan range

SIM

carrier gas

helium, 1 mL/min constant flow

injection

0.5 μL pulsed splitless (60 psi until 0.75 min; splitter open at 0.75 min)

liner

2 mm I.D. FocusLiner with taper

Beschreibung

Hinweis zur Analyse

PAHs are ubiquitous in the environment, resulting from both natural and manmade sources of combustion. Farm animals such as cows can become exposed to them through both consumption of contaminated feed and water, and inhalation of contaminated atmosphere. Consequently, these compounds can be present in dairy products produced from cow′s milk such as cheese and butter.
In this application, EZ-POP NP SPE was used as part of an extraction and cleanup procedure for the analysis of PAHs in butter by GC/MS-SIM. After EZ-POP NP extraction, a secondary cleanup was done using silica gel. This produced an extract with low GC/MS background.

Sonstige Hinweise

Sample pretreatment: 0.5 gm melted butter, diluted to 1 mL in cyclohexane