Skip to Content
Merck

23701

Acrylamide

analytical standard

Synonym(s):

2-Propenamide, Acrylic acid amide

Sign In to View Organizational & Contract Pricing.

Select a Size

100 MG

€55.10

€55.10


Please contact Customer Service for Availability

Request a Bulk Order

About This Item

Linear Formula:
CH2=CHCONH2
CAS Number:
Molecular Weight:
71.08
NACRES:
NA.24
PubChem Substance ID:
eCl@ss:
39031205
UNSPSC Code:
12352111
EC Number:
201-173-7
MDL number:
Beilstein/REAXYS Number:
605349

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

Product Name

Acrylamide, analytical standard

InChI key

HRPVXLWXLXDGHG-UHFFFAOYSA-N

InChI

1S/C3H5NO/c1-2-3(4)5/h2H,1H2,(H2,4,5)

SMILES string

NC(=O)C=C

grade

analytical standard

vapor density

2.45 (vs air)

vapor pressure

0.03 mmHg ( 40 °C)

assay

≥99.0% (GC)

shelf life

limited shelf life, expiry date on the label

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

bp

125 °C/25 mmHg (lit.)

mp

82-86 °C (lit.)

solubility

water: soluble 200 g/L at 20 °C

application(s)

cleaning products
cosmetics
environmental
food and beverages
personal care

format

neat

Quality Level

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
08267A8887A9099
technique(s)

HPLC: suitable, gas chromatography (GC): suitable

technique(s)

HPLC: suitable, gas chromatography (GC): suitable

technique(s)

electrophoresis: suitable

technique(s)

-

application(s)

cleaning products
cosmetics
environmental
food and beverages
personal care

application(s)

cleaning products
cosmetics
environmental
food and beverages
personal care

application(s)

-

application(s)

-

format

neat

format

neat

format

-

format

-

Quality Level

100

Quality Level

300

Quality Level

200

Quality Level

200

grade

analytical standard

grade

certified reference material, TraceCERT®

grade

-

grade

for molecular biology

assay

≥99.0% (GC)

assay

-

assay

≥99%

assay

≥99% (HPLC)

Application

Acrylamide may be used as an analytical reference standard for the determination of the analyte in:
  • Environmental water samples using ion-exclusion chromatography-mass spectrometry system (IEC-MS).[1]
  • Cereal-based food products by gas chromatography coupled to mass spectrometry (GC–MS)[2] and reversed phase-high performance liquid chromatography with diode array detection (RP-HPLC-DAD).[3]
  • Potato-based foods by liquid chromatography with diode array detection (LC–DAD).[4]

Refer to the products certificate of analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

General description

This compound is listed in the SVHC (Substances of very high concern) candidate list of ECHA (European Chemicals Agency)
This substance is listed on the positive list of the EU regulation 10/2011 for plastics intended to come into contact with food. Find all available reference materials for compounds listed in 10/2011 here

related product

Product No.
Description
Pricing

pictograms

Skull and crossbonesHealth hazard

signalword

Danger

Hazard Classifications

Acute Tox. 3 Oral - Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Carc. 1B - Eye Irrit. 2 - Muta. 1B - Repr. 2 - Skin Irrit. 2 - Skin Sens. 1 - STOT RE 1 Oral

target_organs

Peripheral nervous system

Storage Class

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

wgk

WGK 3

flash_point_f

280.4 °F - closed cup

flash_point_c

138 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Trace level determination of acrylamide in cereal-based foods by gas chromatography- mass spectrometry.
Pittet A, et al.
Journal of Chromatography A, 1035(1), 123-130 (2004)
Cheremisinoff, P.
Handbook of Engineering Polymeric Materials, Tech & Eng, 61-61 (1997)
RP-HPLC-DAD studies on acrylamide in cereal-based baby foods
Michalak J, et al.
J. Food Compos. Anal., 32, 68-73 (2013)
Determination of acrylamide in potato chips and crisps by high-performance liquid chromatography.
Gokmen V, et al.
Journal of Chromatography A, 1088(1-2), 193-199 (2005)
RP-HPLC-DAD studies on acrylamide in cereal-based baby foods.
Michalak, Joanna, Elzbieta Gujska, and Andrzej Kuncewicz.
Journal of Food Biochemistry, 32.1, 68-68 (2013)

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service