Accéder au contenu
Merck

P2B500V05

Module d′ultrafiltration à cassette Pellicon® 2 Biomax®

filtration area 0.5 m2, NMWCO 500 kDa

Synonyme(s) :

Pellicon® 2 Cassette Ultrafiltration Module Biomax-500 V 0.5 m2

Se connecter pour consulter vos tarifs contractuels et ceux de votre entreprise/organisme

Sélectionner une taille de conditionnement

1 EA

3 780,00 €

3 780,00 €


Date d'expédition estimée le02 février 2026Détails



A propos de cet article

Code UNSPSC :
23151806

Passer à

Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider

Matériaux

polyethersulfone
polypropylene screen
polyurethane adhesive

Niveau de qualité

Fabricant/nom de marque

Pellicon®

Paramètres

0.33 bar max. transmembrane pressure (5 psig) (reverse)
5-35 L/min recirculation rate at 0.4 bar (6 psi)
7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

Technique(s)

analytical sample preparation: suitable
protein purification: suitable

Hauteur

2.16 cm (0.85 in.)

Longueur

21 cm (8.3 in.)

Largeur

17.8 cm (7.0 in.)

Surface de filtration

0.5 m2

Surface nominale de la membrane

0.5 m2

Extractibles par gravimétrie

≤1500 mg/m2

Matrice

Biomax®

Dimension de pores

500 kDa NMWCO

pH

1-14

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Comparer avec des articles similaires

Voir la comparaison complète

Montrer les différences

1 of 4

Cet article
P2B500C05P2B005V05P2B300V05
matrix

Biomax®

matrix

Biomax®

matrix

Biomax®

matrix

Biomax®

pore size

500 kDa NMWCO

pore size

500 kDa NMWCO

pore size

5 kDa NMWCO

pore size

300 kDa NMWCO

material

polyethersulfone , polyurethane adhesive, polypropylene screen

material

polyethersulfone , polypropylene screen, polyurethane adhesive

material

polyethersulfone , polypropylene screen, polyurethane adhesive

material

polyethersulfone , polypropylene screen, polyurethane adhesive

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward), 5-35 L/min recirculation rate at 0.4 bar (6 psi)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

Description générale

The Pellicon® 2 Ultrafiltration BIOMAX 500 Cassette sets the standard in cassette-style tangential flow filtration devices. P2B500V05 was designed with process scale-up and applications development in mind.

Millipore′s BIOMAX 500 polyethersulfone membrane has void-free structures that guard against leakage of solutes through microdefects normally associated with voids beneath the thin skins of conventional UF membranes. These void-free membranes are more permeable, resulting in high-flux with equivalent or superior product retention. These void-free membranes provide the advantages of fast, high yield processing and smaller systems.

The Pellicon® 2 Cassette Ultrafiltration BIOMAX Module feature a filtration area of 0.5 m2 with a pore size of 500 kDa NMWCO.

Application

Concentration, desalting or buffer exchange of:
  • Protein solutions
  • Polysaccharide solutions
  • Virus suspensions


Harvest, washing or clarification of:
  • Cell cultures and lysates
  • Colloidal suspensions
  • Viral cultures

Caractéristiques et avantages

  • Type V screen (open channel)
  • Leading-edge void- free membranes to match virtually any separation challenge
  • Short flow path for higher flux and higher resolution separation capability
  • Choice of flow channel configuration providing process optimization capability
  • Predictable, fast, scale-up
  • True linear scalability from laboratory size modules to industrial assemblies for processing thousands of liters
  • Brings higher resolution, improved yields and superior back-pressure resistance
  • Ultracel membranes are composite membranes cast on a microporous substrate for defect-free membranes with superior

Remarque sur l'analyse

Gravimetric Extractables: after a water flush

Autres remarques

Prefiltration Rquirements: 100 µm
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Informations légales

BIOMAX is a registered trademark of Merck KGaA, Darmstadt, Germany
Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany

Code de la classe de stockage

10 - Combustible liquids

Classe de danger pour l'eau (WGK)

WGK 2


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Questions

Reviews

No rating value

Active Filters

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique