Přejít k obsahu
Merck

Přeskočit na

IPVH08100

Immobilon® -P PVDF Membrane

10 sheets, 8 cm x 10 cm, 0.45 µm pore size, transfer membrane

Synonyma:

PVDF Blotting Membrane

Přihlásit pro zobrazení organizačních a smluvních cen.

Vybrat velikost

Změnit zobrazení
Vám/SKUDostupnostCena
10 ea
Zkontrolujte dostupnost v košíku
4 760,00 Kč

O této položce

UNSPSC Code:
41105339
eCl@ss:
32031602
NACRES:
NB.22
Material:
PVDF membrane, plain filter, white filter
Detection method:
chemiluminescent, colorimetric, fluorometric, radioactive
Pore size:
0.45 μm pore size
Compatibility:
for use with Amido black, for use with CPTS, for use with Colloidal gold, for use with Coomassie brilliant blue, for use with India ink, for use with Ponceau-S red, for use with Sypro<TMSYMBOL></TMSYMBOL> ruby, for use with Toluidine blue, for use with Transillumination

4 760,00 Kč


Zkontrolujte dostupnost v košíku

​
Technický servis
Potřebujete pomoc? Náš tým zkušených odborníků je vám k dispozici.
Dovolte nám, abychom vám pomohli


Název produktu

Immobilon®-P PVDF Membrane, 10 sheets, 8 cm x 10 cm, 0.45 µm pore size, Hydrophobic PVDF Transfer Membrane for western blotting.

Quality Segment

material

PVDF membrane, plain filter, white filter

feature

hydrophobic

manufacturer/tradename

Immobilon®

technique(s)

dot blot: suitable, electrophoresis transfer: suitable, western blot: suitable

filter L × W

8 cm × 10 cm

pore size

0.45 μm pore size

capacity

160 μg/cm2 adsorption capacity (insulin), 215 μg/cm2 adsorption capacity (BSA), 294 μg/cm2 adsorption capacity (goat IgG)

compatibility

for use with Amido black, for use with CPTS, for use with Colloidal gold, for use with Coomassie brilliant blue, for use with India ink, for use with Ponceau-S red, for use with Sypro<TMSYMBOL></TMSYMBOL> ruby, for use with Toluidine blue, for use with Transillumination

detection method

chemiluminescent, colorimetric, fluorometric, radioactive

shipped in

ambient

General description

Filter Code: IPVH
Overview
- Millipore offers four different Immobilon PVDF membranes, each optimized for different protein blotting applications.
Immobilon PVDF membranes provide many advantages compared to nitrocellulose. They won’t crack or curl, and they can be cut without fracturing. They also have low background, broad solvent compatibility, and superior staining capabilities. In addition, they can be reprobed multiple times.

Immobilon-P Transfer Membrane:
- 45 µm pore size Recommended for most western blotting, especially proteins greater than 20 kDa
- Millipore′s Rapid Immunodetection Protocol reduces detection times by up to 2 hours by eliminating membrane blocking and several wash steps with no loss of sensitivity or specificity

Immobilon-E Membrane:
- the only PVDF membrane that wets out in aqueous buffers, eliminating the methanol pre-wet step.
- 45 µm pore size recommended for most western blotting, especially proteins greater than 20 kDa

Blotting Sandwiches:
- When you need to process multiple blots, blotting sandwiches are a convenient, time-saving choice. Our sandwiches include sheets of Immobilon-P membrane interleaved with pre-cut sheets of chromatography-grade blotting filter paper and are compatible with any standard wet transfer device.

Blotting Filter Paper:
- Chromatography-grade blotting filter paper pre-cut to the most popular western blotting sizes.

Immobilon-PSQ Membrane:
- 0.2 µm pore size and a large internal structure
- Higher protein adsorption and sequencing yields than other membranes
- Recommended for blotting proteins less than 20 kDa
- Prevents blow-through of low molecular weight proteins

Immobilon-FL Membrane:
- The first transfer membrane optimized for fluorescence applications
- Extremely low background improves sensitivity of all fluorescence detection protocols
- Compatible with all commonly used fluorescent probes at all excitation and emission wavelengths
- Ideal for multiplexing and chemifluorescence applications

Immobilon® PVDF membranes are offered in four types, each optimized for a different protein blotting application. Convenient blotting sandwiches feature pre-cut sheets of membrane and blotting filter paper. Immobilon PVDF membranes have high protein adsorption, so you won’t lose proteins during transfer or reprobing. The open pore structure makes it easy to access bound proteins and remove unbound probes. In addition, Immobilon PVDF membranes optimized for fluorescent blots dramatically increase signal-to-noise ratios for high sensitivity in quantitative, multiplexing applications.

Features & Benefits:
- Won’t crack, curl or fracture when cut
- Low background
- Superior staining capabilities
- Can be reprobed multiple times

Applications:
- Western Blotting, Immunoblotting, Dot Blotting, Protein Sequencing;
- Compatible with Chemiluminescent, Fluorescent, Radioactive, Chromogenic, and Chemifluorescent Detection
- Compatible with all commonly used fluorescent probes at all excitation and emission wavelengths
Primary Binding Mechanisms: Electrostatic, hydrophobic

Application

10 sheets, 8 cm x 10 cm, 0.45 µm pore size, Hydrophobic PVDF Transfer Membrane for western blotting.

Legal Information

Immobilon is a registered trademark of Merck KGaA, Darmstadt, Germany

Porovnat podobné položky

Zobrazit úplné porovnání

Zobrazit rozdíly

1 of 1

Tato položka
IPVH10100IPVH08130IPVH304F0
description

10 sheets, 8 cm x 10 cm, 0.45 µm pore size, Hydrophobic PVDF Transfer Membrane for western blotting.

description

10 sheets, 10 cm x 10 cm, 0.45 µm pore size, Hydrophobic PVDF Transfer Membrane for western blotting.

description

10 sheets, 8.5 cm x 13.5 cm, 0.45 µm pore size, Hydrophobic PVDF Transfer Membrane for western blotting.

description

10 sheets, 26 cm x 26 cm, 0.45 µm pore size, Hydrophobic PVDF Transfer Membrane for western blotting.

pore size

0.45 μm pore size

pore size

0.45 μm pore size

pore size

0.45 μm pore size

pore size

0.45 μm pore size

Quality Level

400

Quality Level

400

Quality Level

400

Quality Level

400

detection method

fluorometric, chemiluminescent, colorimetric, radioactive

detection method

colorimetric, chemiluminescent, fluorometric, radioactive

detection method

fluorometric, radioactive, colorimetric, chemiluminescent

detection method

fluorometric, radioactive, colorimetric, chemiluminescent

material

white filter, PVDF membrane, plain filter

material

plain filter, white filter, PVDF membrane

material

PVDF membrane, plain filter, white filter

material

white filter, PVDF membrane, plain filter

compatibility

for use with Ponceau-S red, for use with India ink, for use with Coomassie brilliant blue, for use with Amido black, for use with Colloidal gold, for use with Sypro<TMSYMBOL></TMSYMBOL> ruby, for use with Toluidine blue, for use with CPTS, for use with Transillumination

compatibility

for use with Coomassie brilliant blue, for use with Sypro<TMSYMBOL></TMSYMBOL> ruby, for use with CPTS, for use with Ponceau-S red, for use with India ink, for use with Colloidal gold, for use with Toluidine blue, for use with Transillumination, for use with Amido black

compatibility

for use with Colloidal gold, for use with Sypro<TMSYMBOL></TMSYMBOL> ruby, for use with Amido black, for use with CPTS, for use with Transillumination, for use with Toluidine blue, for use with Coomassie brilliant blue, for use with Ponceau-S red, for use with India ink

compatibility

for use with Colloidal gold, for use with Coomassie brilliant blue, for use with India ink, for use with CPTS, for use with Toluidine blue, for use with Ponceau-S red, for use with Sypro<TMSYMBOL></TMSYMBOL> ruby, for use with Amido black, for use with Transillumination

manufacturer/tradename

Immobilon®

manufacturer/tradename

Immobilon®

manufacturer/tradename

Immobilon®

manufacturer/tradename

Immobilon®


Still not finding the right product?

Explore all of our products under Immobilon®-P PVDF Membrane




Vyberte jednu z posledních verzí:

Osvědčení o analýze (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumenty section.

Potřebujete-li pomoc, obraťte se na Zákaznická podpora

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů



Questions

Reviews

No rating value

Active Filters