This product is recommended for use in fluorescence microscopy and has not been evaluated for use in Flow Cytometry. However, the following citation reports the use of BioTracker 488 Green Lipid Droplet Dye in Flow Cytometry.
Vybrat velikost
| Vám/SKU | Dostupnost | Cena |
|---|---|---|
125 μL | Odhaduje se, že bude odesláno dnesodAreál Kühne+Nagel spol. s r.o. | 12 900,00 Kč |
O této položce
12 900,00 Kč
Odhaduje se, že bude odesláno dnespodrobné informace
technique(s)
cell based assay: suitable, live cell imaging : suitable
detection method
fluorometric
shipped in
ambient
storage temp.
2-8°C
General description
BioTracker Lipid dyes rapidly stain lipid droplets in live or fixed cells with no wash step and minimal background staining of cellular membranes or other organelles. Cells also can be fixed and permeabilized after staining.
The BioTracker 488 Green Lipid Dye has an excitation around 430 nm, and can be excited equally well at 405 nm or 488 nm. In cells, it stains lipid droplets with bright green fluorescence using the FITC detection channel.
Spectral Properties
Absorbance: 427nm
Emission: 585nm
Application
Cell Imaging
Live Cell Dye
Physical form
Preparation Note
Note: Centrifuge vial briefly to collect contents at bottom of vial before opening.
Analysis Note
Absorbance: 427nm
Emission: 585nm
Disclaimer
1 of 1
Tato položka | |||
|---|---|---|---|
| description Live cell imaging dye that rapidly stains lipid droplets with no wash steps and minimal background staining of other cellular membranes or organelles. | description Live cell imaging mitochondrial dye that stains the membrane of mitochondria used to detect cell viability, metabolic activity and overall cell health. | description Live cell imaging cell proliferation kit based on carboxyfluorescein succinimidyl ester (CFSE) used for fluorescent cell labeling in flow cytometry applications. | description Live cell imaging microtubule dye for imaging the cytoskeleton of living cells |
| technique(s) cell based assay: suitable | technique(s) cell based assay: suitable | technique(s) cell based assay: suitable | technique(s) cell based assay: suitable |
| shipped in ambient | shipped in ambient | shipped in ambient | shipped in ambient |
| storage temp. 2-8°C | storage temp. -10 to -25°C | storage temp. -10 to -25°C | storage temp. 2-8°C |
| detection method fluorometric | detection method fluorometric | detection method fluorometric | detection method fluorometric |
Skladovací třída
10 - Combustible liquids
Co se děje?
WGK 1
Bod vzplanutí (°F)
188.6 °F - (refers to pure substance)
Bod vzplanutí (°C)
87 °C - (refers to pure substance)
Vyberte jednu z posledních verzí:
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
-
Good afternoon, I would like to to know if it is possible to use the reagent also by flow cytometry application, and if there are any references or examples of it having been successfully used in this context, thank you
1 answer-
Helpful?
-
-
Are there any solutions for the high background issue experienced when using the product with heart tissue cells?
1 answer-
The high background issue could be due to the use of antifade, which is not recommended. Instead, it's suggested to use PBS as the mounting medium and nail polish as the coverslip sealant. Additionally, using other mounting media such as EverBrite™ or FluoroShield™ may impact staining patterns, so it's important to consider the recommended mounting methods to avoid issues with signal intensity and staining patterns.
Helpful?
-
-
Is BioTracker 488 Green Lipid Dye (SCT144) toxic for the cells? Can they be monitored for extra time after staining? How long does the stain last in this case?
1 answer-
No cytotoxicity of this dye has been observed with incubation periods of up to 24 hours. Cytotoxicity beyond the 24-hour incubation period has not been studied. Suitability for extended incubation times would have to be determined by the end user.
Helpful?
-