Přejít k obsahu
Merck

Přeskočit na

QR0200

Quantitative RT-PCR ReadyMix™

One step RT-qPCR for probe-based methods, MMLV & hot-start Taq

Synonyma:

1-step RT-qPCR mix, Quantitative real-time PCR master mix

Přihlásit pro zobrazení organizačních a smluvních cen.

Vybrat velikost

Změnit zobrazení
Vám/SKUDostupnostCena
1 kit
Obraťte se na zákaznický servis a vyžádejte si informaci o dostupnosti.
12 900,00 Kč

O této položce

NACRES:
NA.55
UNSPSC Code:
41106300

12 900,00 Kč


Obraťte se na zákaznický servis a vyžádejte si informaci o dostupnosti.

​
Technický servis
Potřebujete pomoc? Náš tým zkušených odborníků je vám k dispozici.
Dovolte nám, abychom vám pomohli


Quality Segment

usage

sufficient for 250 reactions

feature

dNTPs included, hotstart

technique(s)

RT-qPCR: suitable, qPCR: suitable, whole genome amplification: suitable

color

colorless

input

purified RNA

compatibility

ABI 5700, ABI 7000, ABI 7300, ABI 7500 Fast, ABI 7500, ABI 7700, ABI 7900 HT , ABI 7900 HT Fast, ABI 7900, ABI StepOne, ABI StepOnePlus, ABI ViiA 7, Bio-Rad CFX384, Bio-Rad CFX96, Bio-Rad MJ Chromo4, Bio-Rad MJ Opticon 2, Bio-Rad MJ Opticon, Bio-Rad MiniOpticon, Bio-Rad MyiQ, Bio-Rad iCycler iQ, Bio-Rad iQ5, Cepheid SmartCycler, Eppendorf® Mastercycler ep realplex2 s, Eppendorf® Mastercycler ep realplex, Illumina Eco qPCR, Qiagen Corbett Rotor-Gene 3000, Qiagen Corbett Rotor-Gene 6000, Qiagen Corbett Rotor-Gene Q, Roche LightCycler 480, Strategene Mx3000P, Strategene Mx3005P, Strategene Mx4000

detection method

probe-based

shipped in

wet ice

storage temp.

−20°C

General description

Quantitative RT-PCR ReadyMix™ combines Moloney Murine Leukemia Virus Reverse Transcriptase (M-MLV RT) and JumpStart™ Taq DNA polymerase in a one-step RT-PCR kit designed for the measurement of gene expression. This convenient 2X master mix includes M-MLV RT, JumpStart™ Taq DNA polymerase, 99% pure deoxynucleotides, buffer, glass passivator, and stabilizers. The JumpStart™ Taq DNA polymerase is an antibody-inactivated hot-start enzyme. Once the reaction temperature reaches 70°C, the DNA polymerase-antibody complex dissociates and Taq DNA polymerase activity is restored. This antibody-enzyme complex allows for easy and convenient set-up with less contamination risk than manual hot-start techniques. This kit has been formulated for fluorogenic hybridization probe-based detection methods.

Application

Quantitative RT-PCR ReadyMix™ has been used in the quantification of messenger RNA (mRNA) levels of specific expressed genes by quantitative reverse-transcription polymerase chain reaction (RT-qPCR).

Features and Benefits

  • The master mix allows consistency and reproducibility from one reaction to the next
  • Reduced risk of contamination from multiple pipetting steps
  • Reduced set-up time as compared to manual or wax Hot Start methods
  • JumpStart™Taq Polymerase reduces primer-dimer and non-specific product formation
  • Broad instrument compatibility
  • Includes a separate ROX reference dye vial for reaction normalization

Packaging

1 kit sufficient for 250 reactions at 20 μL each or for 100 reactions at 50 μL each.

Legal Information

This product is for research use only.
Eppendorf is a registered trademark of Eppendorf SE
JumpStart is a trademark of Sigma-Aldrich Co. LLC
ReadyMix is a trademark of Sigma-Aldrich Co. LLC

Porovnat podobné položky

Zobrazit úplné porovnání

Zobrazit rozdíly

1 of 1

Tato položka
D7440L6669L6544
description

One step RT-qPCR for probe-based methods, MMLV & hot-start Taq

description

For probe-based real-time PCR

description

For fast probe-based quantitative PCR

description

For fast SYBR Green quantitative PCR

technique(s)

RT-qPCR: suitable, whole genome amplification: suitable

technique(s)

RT-qPCR: suitable, whole genome amplification: suitable

technique(s)

whole genome amplification: suitable, qPCR: suitable, RT-qPCR: suitable

technique(s)

qPCR: suitable, whole genome amplification: suitable, RT-qPCR: suitable

feature

dNTPs included, hotstart

feature

hotstart, dNTPs included

feature

hotstart, dNTPs included

feature

dNTPs included, hotstart

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

storage temp.

−20°C

storage temp.

−20°C

storage temp.

−20°C

storage temp.

−20°C

compatibility

ABI 5700, ABI 7500, Qiagen Corbett Rotor-Gene 3000, ABI 7000, Strategene Mx3005P, Bio-Rad iQ5, Bio-Rad iCycler iQ, ABI 7700, ABI ViiA 7, ABI 7300, Bio-Rad MJ Opticon, Eppendorf® Mastercycler ep realplex2 s, ABI 7900 HT , Bio-Rad CFX96, Bio-Rad CFX384, ABI StepOnePlus, Strategene Mx3000P, Qiagen Corbett Rotor-Gene Q, Bio-Rad MJ Opticon 2, Strategene Mx4000, Bio-Rad MiniOpticon, Bio-Rad MJ Chromo4, ABI 7500 Fast, Cepheid SmartCycler, Illumina Eco qPCR, Bio-Rad MyiQ, Qiagen Corbett Rotor-Gene 6000, Roche LightCycler 480, ABI 7900 HT Fast

compatibility

for use with Qiagen Corbett Rotor-Gene 3000, for use with ABI 7300, for use with Bio-Rad MJ Opticon 2, for use with Qiagen Corbett Rotor-Gene Q, for use with ABI ViiA 7, for use with ABI StepOne, for use with Strategene Mx4000, for use with Illumina Eco qPCR, for use with ABI 7900 Fast, Bio-Rad iQ 5, for use with Eppendorf® Mastercycler ep realplex, for use with Bio-Rad MJ Chromo4, Bio-Rad iCycler iQ, for use with ABI 7700, for use with ABI StepOnePlus, for use with Bio-Rad MJ Opticon Cepheid SmartCycler, for use with Bio-Rad CFX96, for use with Eppendorf® Mastercycler ep realplex2 s, for use with Strategene Mx3000P, for use with ABI 5700, for use with Strategene Mx3005P, for use with Bio-Rad CFX384, for use with ABI 7000, Bio-Rad MyiQ ( ), for use with Bio-Rad MiniOpticon, for use with ABI 7500 Fast, for use with ABI 7900 HT, for use with Qiagen Corbett Rotor-Gene 6000, for use with Roche LightCycler 480

compatibility

Bio-Rad MyiQ ( ), for use with Qiagen Corbett Rotor-Gene 6000, for use with ABI 7900 HT, for use with Roche LightCycler 480, for use with ABI StepOne, for use with Bio-Rad CFX384, for use with Bio-Rad MiniOpticon, for use with Bio-Rad CFX96, for use with Bio-Rad MJ Opticon 2, for use with ABI StepOnePlus, for use with Eppendorf® Mastercycler ep realplex2 s, for use with ABI 7900 Fast, for use with ABI ViiA 7, for use with Bio-Rad MJ Opticon Cepheid SmartCycler, for use with Illumina Eco qPCR, for use with ABI 7500 Fast, for use with Strategene Mx3000P, for use with Strategene Mx3005P, for use with ABI 5700, for use with Bio-Rad MJ Chromo4, for use with Qiagen Corbett Rotor-Gene 3000, Bio-Rad iCycler iQ, for use with ABI 7000, for use with Qiagen Corbett Rotor-Gene Q, for use with ABI 7300, for use with ABI 7700, for use with Strategene Mx4000, Bio-Rad iQ 5

compatibility

for use with Roche LightCycler 480, for use with Bio-Rad CFX96, for use with Bio-Rad MJ Chromo4, for use with Bio-Rad MiniOpticon, for use with Qiagen Corbett Rotor-Gene 3000, for use with Qiagen Corbett Rotor-Gene Q, for use with Eppendorf® Mastercycler ep realplex, for use with ABI 5700, for use with ABI 7900 Fast, for use with ABI ViiA 7, for use with Strategene Mx3005P, for use with Bio-Rad CFX384, for use with Strategene Mx4000, for use with Bio-Rad MJ Opticon, Bio-Rad iCycler iQ, for use with Bio-Rad MJ Opticon Cepheid SmartCycler, for use with ABI StepOne, for use with Eppendorf® Mastercycler ep realplex2 s, Bio-Rad iQ 5, for use with Bio-Rad MJ Opticon 2, for use with ABI 7000, for use with ABI 7700, for use with ABI StepOnePlus, for use with ABI 7500, for use with Qiagen Corbett Rotor-Gene 6000, for use with ABI 7500 Fast, for use with Illumina Eco qPCR, Bio-Rad MyiQ, for use with ABI 7300, for use with Strategene Mx3000P, for use with ABI 7900 HT

usage

sufficient for 250 reactions

usage

sufficient for 20 reactions, sufficient for 400 reactions, sufficient for 100 reactions

usage

sufficient for 100 reactions, sufficient for 500 reactions, sufficient for 2000 reactions

usage

sufficient for 100 reactions, sufficient for 500 reactions, sufficient for 2000 reactions


Pouze součásti soupravy

Č. produktu
Popis

  • Probe Based qRT-PCR ReadyMix 2 X

  • Moloney Murine Leukemia Viral Reverse Transcriptase (M-MLV RT) 5000 U

Součásti soupravy, které jsou dostupné také samostatně

Č. produktu
Popis
Bezpečností list & Stanovení ceny

  • 10X PCR Buffer, Optimized for routine PCR with MgCl2 included 1.5 mL/vial
    Bezpečností list

  • Magnesium chloride solution, PCR Reagent, 25 mM MgCI2 solution for PCR 25 mM
    Bezpečností list

  • 10X PCR Buffer, Optimized for routine PCR with MgCl2 included 100 X
    Bezpečností list

Piktogramy

Exclamation markEnvironment

Skladovací třída

12 - Non Combustible Liquids

Co se děje?

WGK 3

Výstražné slovo

Danger

Hazard Classifications

Aquatic Acute 1 - Aquatic Chronic 1 - ED ENV 1 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1



Vyberte jednu z posledních verzí:

Osvědčení o analýze (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumenty section.

Potřebujete-li pomoc, obraťte se na Zákaznická podpora

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů




Questions

Reviews

No rating value

Active Filters