Skip to Content
Merck

UFC9030

Amicon® Ultra Centrifugal Filter, 30 kDa MWCO

greener alternative

sample volume 15 mL, regenerated cellulose membrane, MWCO 30 kDa

Amicon® Ultra Centrifugal Filter, 30 kDa MWCO

Synonym(s):

15 mL sample volume, 30 kDa MWCO, Centrifugal concentrator


Sign In to View Organizational & Contract Pricing

Select a Size

8 PKG

1.130,00 kr.

24 PKG

3.020,00 kr.

96 PKG

11.210,00 kr.

1.130,00 kr.


Please contact Customer Service for Availability

Request a Bulk Order

About This Item

UNSPSC Code:
41104916
eCl@ss:
36100101
NACRES:
NB.24

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

material

polyethylene cap
polyethylene liner
polypropylene tube
regenerated cellulose membrane
regenerated cellulose support
styrene-butadiene housing

Quality Level

sterility

non-sterile

product line

Amicon®

packaging

pkg of 24 pkg
pkg of 8 pkg
pkg of 96 pkg

manufacturer/tradename

Amicon® Ultra

sustainability

Greener Alternative Product

parameter

15 mL sample volume

technique(s)

protein extraction: suitable
protein purification: suitable

L

12.1 cm (4.807 in.)

diam.

2.97 cm

filtration area

7.6 cm2

volume

15 mL

working volume

≤15 mL
15 mL

pore size

30 kDa MWCO

greener alternative category

shipped in

ambient

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
UFC8030UFC203024UFC5030
parameter

15 mL sample volume

parameter

4 mL sample volume

parameter

2 mL sample volume

parameter

0.5 mL sample volume

material

polyethylene cap, polypropylene tube, regenerated cellulose support, polyethylene liner, styrene-butadiene housing, regenerated cellulose membrane

material

polyethylene cap, polyethylene liner, polypropylene tube, regenerated cellulose membrane, regenerated cellulose support, styrene-butadiene housing

material

polypropylene tube (for collection), regenerated cellulose membrane, styrene-butadiene housing

material

polypropylene cap, polypropylene tube, regenerated cellulose membrane, styrene-butadiene housing

manufacturer/tradename

Amicon® Ultra

manufacturer/tradename

Amicon® Ultra

manufacturer/tradename

Amicon® Ultra

manufacturer/tradename

Amicon® Ultra

pore size

30 kDa MWCO

pore size

30 kDa MWCO

pore size

30 kDa MWCO

pore size

30 kDa MWCO

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

product line

Amicon®

product line

Amicon®

product line

Amicon®

product line

Amicon®

General description

Amicon® Ultra 15 mL centrifugal devices with Ultracel® 30,000 Dalton molecular weight cutoff filters provide fast ultrafiltration, and reliable retention of macromolecules. For example, Ovalbumin (45 kDa) at 1 mg/ml initial concentration is retained at >95% .

The vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 80-fold concentration. Solute polarization and subsequent fouling of the membrane are minimized by the vertical design, and a physical deadstop in the filter device prevents spinning to dryness and potential sample loss.

The concentrate is collected from the filter device sample reservoir using a pipetter, while the ultrafiltrate is collected in the provided centrifuge tube. The device can be spun in a swinging bucket or fixed angle rotor. With their vertical membrane design and deadstop, Amicon® Ultra 15 mL filters deliver the highest recovery with short spin times.
We are committed to bringing you Greener Alternative Products, which have been re-engineered to enable more sustainable research solutions. The inner filtration device is made from 60% bio-circular material allocated using the ISCC mass balance approach. Click here for more information.

Application

  • Ultrafiltration with 30,000 Dalton molecular weight cutoff Ultracel® membrane.
  • Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms.
  • Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLS.
  • Concentration of dilute or pre-purified proteins from column eluents.
  • Desalting, buffer exchange and protein dialysis.

Features and Benefits

  • Ultracel® regenerated cellulose membrane with 30 kDa NMWCO delivers retentate recovery of greater than 90%.
  • Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 10–15 minutes).
  • Heat-sealed membrane minimizes downstream extractables.
  • 100% integrity tested for reliable performance.
  • Convenient sample monitoring with translucent housing and volume gradations.
  • Direct pipettor sample access eliminates processing step to recover concentrate.
  • High concentration factors of 80–100X.

Physical form

Color Code: Clear with pink cap

Legal Information

Amicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Articles

Explore ultrafiltration membrane principles and benefits for protein sample preparation, including solvent exchange and sample concentration.

Filtration methods and membrane filter selection in nanoparticle purification and production.

Protocols

Purification protocols for immunoglobulins generally include affinity binding to Protein A or G chromatography media, washing unbound proteins, and eluting with a low pH buffer.

Related Content

Purification methods for downstream analysis reduce sample complexity, remove interferences, and concentrate analytes for more accurate results.

Questions

1–8 of 8 Questions  
  1. how many units are there in 1 pkg

    1 answer
    1. This product is packaged as a box of 8 tubes, 24 tubes, or 96 tubes.

      Helpful?

  2. How many individual columns come in one package. For example, if I wanted to purchase the 24package option, wil I get 24 columns or 24 packages of x number of columns?

    1 answer
    1. A package of 24 would equate to 24 Ultra Centrifugal Filters.

      Helpful?

  3. Hi there, I need to extract exosome in the range of 30 to 150 nm. Which Ultra Centrifugal Filter is fit for my work? Thank you for your advice in advance.

    1 answer
    1. We have performed studies of nanometer particles and all of our studies show that using a 100 kda molecular weight cutoff should be fine to trap particles greater than 10 nm.  

      Helpful?

  4. Can this item be sterilised, and if so, what is the best method (e.g., autoclaving) to ensure that product function and integrity are maintained?

    1 answer
    1. This item cannot be autoclaved. Sterilization with Ethylene Oxide is possible, but the method has not been validated.

      Helpful?

  5. Can the product be washed and re-used?

    1 answer
    1. This product is intended for single use. Repeated usage may result in declining performance.

      Helpful?

  6. How many times can sample be added to the same filter unit? For example: If I have 100 mL cell free supernatant and want to add 12 mL at a time, centrifuge and collect retentate - followed by discarding the flow through and pouring the next 12 mL etc.

    1 answer
    1. The same Amicon filter unit can be used for repeated spins with the same sample. However, repeated spins may lead to increased clogging, resulting in slower flow rates and longer spin times.

      Helpful?

  7. I noticed no volume change after centrifuging 10mL cell media at 14,000xg for 20minutes. Could this be due to unsuccessful concentration?

    1 answer
    1. The lack of volume change suggests that the sample may contain a high amount of particulate matter, leading to rapid clogging and preventing effective concentration.

      Helpful?

  8. Hello! Our lab had to move to a different area of our building and we found some probably quite old boxes of Amicon Ultra 15s (Cat UFC903096, lot R8CN67048). Does this product have an expiration date/shelf life? If so, has this lot surpassed it?

    1 answer
    1. This product is not assigned an expiration date or recommended retest date. Products with no expiration date or recommended retest date should be routinely inspected by customers to ensure they perform as expected. These products are also subject to a one-year warranty from the date of shipment.

      For more information, you may access the "Product Dating Information" document under "ADDITIONAL USEFUL DOCUMENTS ABOUT OUR PRODUCTS" at the bottom of the Quality Services page with this link: https://www.sigmaaldrich.com/life-science/quality-and-regulatory-management/quality-services.

      Helpful?

Reviews

Active Filters

  1. San Diego
    • Review 1
    • Votes 10
    5 out of 5 stars.

    Amicon Ultra-15-An excellent choice

    This was back ordered a long time, but it is an excellent concentrator.

    Helpful?

  2. 1 Ratings-only review

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service