Seleccione un Tamaño
Preguntar
No se puede adquirir este artículo como usuario invitado. Para más información, póngase en contacto con nosotros en +34 912 158 016o
.Acerca de este artículo
Saltar a
Materiales
PVDF
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap (Gamma stable)
silicone seal
Nivel de calidad
cumplimiento norm.
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
esterilidad
non-sterile
Compatibilidad de esterilización
autoclavable compatible
Línea del producto
Opticap® XL 2
Características
hydrophilic
fabricante / nombre comercial
Opticap®
Parámetros
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.4 bar max. differential pressure (50 psid) at 25 °C (Forward)
3.4 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
técnicas
bioburden reduction: suitable
Longitud
5.6 in.
Anchura
3.3 in.
longitud nominal del cartucho
2 in. (5 cm)
Diámetro
8.4 cm (3.3 in.)
filtración área
0.09 m2
diám. conexión a entrada
3/4 in.
An entrada a salida
13.5 cm (5.3 in.)
diám. conexión a salida
3/4 in.
impurezas
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
extraíbles gravimétricos
≤10 mg/capsule
Matriz
Durapore®
tamaño de poro
0.45 μm
entrada
sample type liquid
punto de burbuja
≥1930 mbar (28 psig), air with water at 23 °C
Adaptador
1/4 in. drain/vent hose barb (with double O-ring Seal)
inlet sanitary flange
outlet sanitary flange
(19 mm (3/4 in.) Sanitary Flange Inlet and Outlet)
¿Está buscando productos similares? Visita Guía de comparación de productos
1 of 4
Este artículo | KPHLA02TT3 | KPHLA02FH3 | KPHLA02TH3 |
|---|---|---|---|
| pore size 0.45 μm | pore size 0.45 μm | pore size 0.45 μm | pore size 0.45 μm |
| filtration area 0.09 m2 | filtration area 0.09 m2 | filtration area 0.09 m2 | filtration area 0.09 m2 |
| technique(s) bioburden reduction: suitable | technique(s) bioburden reduction: suitable | technique(s) bioburden reduction: suitable | technique(s) bioburden reduction: suitable |
| product line Opticap® XL 2 | product line Opticap® XL 2 | product line Opticap® XL 2 | product line Opticap® XL 2 |
| manufacturer/tradename Opticap® | manufacturer/tradename Opticap® | manufacturer/tradename Opticap® | manufacturer/tradename Opticap® |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
Descripción general
Envase
Nota de preparación
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Nota de análisis
Otras notas
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Información legal
Cláusula de descargo de responsabilidad
Cumpla las GMP con el programa Emprove®.
Acelere la cualificación, mantenga la conformidad y ahorre tiempo con Emprove® Dossiers.
Nota: será redirigido a EmproveSuite.com. Su nombre de usuario y contraseña son independientes de SigmaAldrich.com y pueden diferir.
Regístrese gratis y acceda a Emprove® Dossiers en cuestión de minutos. Actualice su plan de suscripción para desbloquear contenidos avanzados y personalizados en la Emprove® Suite
¿No encuentra lo que busca? Visite la página de ayuda del programa Emprove®..
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Filtros activos
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.