Ascentis® Express C18, 2 μm UHPLC Column, 2 μm particle size, L × I.D. 10 cm × 3 mm
material
stainless steel column
agency
suitable for USP L1
product line
Ascentis®
feature
endcapped
manufacturer/tradename
Ascentis®
packaging
1 ea of
parameter
1000 bar max. pressure (14500 psi)
60 °C temp. range
technique(s)
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
L × I.D.
10 cm × 3 mm
surface area
120 m2/g
impurities
<5 ppm metals
matrix
Fused-Core particle platform
superficially porous particle
matrix active group
C18 (octadecyl) phase
particle size
2 μm
pore size
90 Å pore size
operating pH
2-9
application(s)
food and beverages
separation technique
reversed phase
Quality Level
¿Está buscando productos similares? Visita Guía de comparación de productos
Categorías relacionadas
1 of 4
Este artículo | 50821-U | 50809-U | 50811-U |
|---|---|---|---|
| particle size 2 μm | particle size 2 μm | particle size 2 μm | particle size 2 μm |
| separation technique reversed phase | separation technique reversed phase | separation technique reversed phase | separation technique reversed phase |
| matrix active group C18 (octadecyl) phase | matrix active group C18 (octadecyl) phase | matrix active group C18 (octadecyl) phase | matrix active group C18 (octadecyl) phase |
| L × I.D. 10 cm × 3 mm | L × I.D. 15 cm × 3 mm | L × I.D. 3 cm × 2.1 mm | L × I.D. 5 cm × 2.1 mm |
| pore size 90 Å pore size | pore size 90 Å pore size | pore size 90 Å pore size | pore size 90 Å pore size |
| technique(s) LC/MS: suitable, UHPLC: suitable, UHPLC-MS: suitable | technique(s) LC/MS: suitable, UHPLC-MS: suitable, UHPLC: suitable | technique(s) LC/MS: suitable, UHPLC-MS: suitable, UHPLC: suitable | technique(s) LC/MS: suitable, UHPLC-MS: suitable, UHPLC: suitable |
Legal Information
related product
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Contenido relacionado
Ascentis® Express 2.0 μm C18 Column Care & Use Sheet
-
What is the Department of Transportation shipping information for this product?
1 respuesta-
¿Le ha resultado útil?
-
Filtros activos
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico