Skip to Content
Merck

283622

Nickel(II) hydroxide

Synonym(s):

Nickel dihydroxide, Nickelous hydroxide

Sign In to View Organizational & Contract Pricing

Select a Size

250 G

€93.60

1 KG

€273.00

€93.60


Available to ship TODAYDetails


Request a Bulk Order

About This Item

Linear Formula:
Ni(OH)2
CAS Number:
Molecular Weight:
92.71
EC Number:
MDL number:
UNSPSC Code:
12352302
PubChem Substance ID:
NACRES:
NA.23
Form:
powder

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

form

powder

reaction suitability

core: nickel

concentration

60.0-70.0% Ni (EDTA titration)

mp

230 °C (lit.)

density

4.1 g/mL (lit.)

application(s)

battery precursors
catalysts
material synthesis precursor

SMILES string

O[Ni]O

InChI

1S/Ni.2H2O/h;2*1H2/q+2;;/p-2

InChI key

BFDHFSHZJLFAMC-UHFFFAOYSA-L

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
544183561142451193
form

powder

form

powder

form

powder

form

powder

Quality Level

200

Quality Level

100

Quality Level

100

Quality Level

200

grade

reference material

grade

-

grade

anhydrous

grade

anhydrous

mp

230 °C (lit.)

mp

-

mp

963 °C (lit.)

mp

-

density

4.1 g/mL (lit.)

density

-

density

5.098 g/mL at 25 °C (lit.)

density

3.55 g/mL at 25 °C (lit.)

concentration

60.0-70.0% Ni (EDTA titration)

concentration

-

concentration

-

concentration

-

Application

Nickel hydroxide was used as a reference material in a study where the influence of stacking faults on the electrochemical activity of Ni(OH)2 electrodes was studied.[1]

Signal Word

Danger

Hazard Classifications

Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Carc. 1A Inhalation - Muta. 2 - Repr. 1B - Resp. Sens. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT RE 1 Inhalation

Target Organs

Lungs

Storage Class Code

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Regulatory Listings

Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.

EU REACH Annex XVII (Restriction List)

CAS No.

Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Jingming Gong et al.
Biosensors & bioelectronics, 25(2), 493-496 (2009-08-04)
A sensitive electrochemical stripping voltammetric biosensor is designed for organophosphate pesticides (OPs) based on solid-phase extraction (SPE) using Ni/Al layered double hydroxides (LDHs) modified glassy carbon electrode (labeled as Ni/Al-LDHs/GCE). The Ni/Al-LDHs as the host are highly efficient to capture
Marcio Vidotti et al.
Journal of nanoscience and nanotechnology, 7(9), 3221-3226 (2007-11-21)
Nickel hydroxide nanoparticles with different amounts of cobalt atoms in the structure forming a unique material, were synthesized by using ultrasonic radiation. The particles of 5 nm diameter were prepared and characterized by X-Ray diffraction, Raman and Infrared spectroscopies, and
Carlos Escudero et al.
Journal of hazardous materials, 164(2-3), 533-541 (2008-09-27)
In this work, a solid waste material from an electroplating industrial plant has been investigated for As(III) and As(V) sorption. This sorbent, a mixture of mainly Fe(III) and Ni(II) (hydr)oxides, has been used both in its native form and entrapped
William Tongamp et al.
Journal of hazardous materials, 167(1-3), 1002-1006 (2009-02-24)
This work discusses an alternative process option for the treatment of polyvinyl chloride (PVC) by producing hydrogen (H(2)) gas, at the same time fixing chlorine for proper environmental control. In the first-stage, a milling operation is performed in a planetary
Jason G Parsons et al.
Environmental toxicology and chemistry, 29(5), 1146-1154 (2010-09-08)
Nanomaterials are of particular interest in environmental chemistry due to their unknown toxicity to living organisms. Reports indicate that nanoparticles (NPs) affect seed germination, but the uptake and biotransformation of metal nanoparticles is not well understood. The present study investigated

Articles

The prevailing strategies for heat and electric-power production that rely on fossil and fission fuels are having a negative impact on the environment and on our living conditions.

Plasmonic nanoparticles have unique optical properties that can be tailored to suit a variety of applications in the biotechnology1–8 and electronics9–16 industries.

Lithium-ion batteries' characteristics make them popular for electricity storage due to portability, rechargeability, and low cost.

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service