Millipore Expresse SPG 0.2 µm, Opticap® XL Capsule

Opticap® XL 300, inlet connection diam. 3/4 in., pore size 0.2 μm

Synonym(s):

Millipore Express® SPG 0.2 µm, Opticap® XL Capsule, Gamma Phobic Opticap® XL 300 Express SPG 0.2 sanitary flange

Sign In to View Organizational & Contract Pricing

Select a Size

3 EA

€727.00

€727.00


Estimated to ship on07 January 2026Details



About This Item

UNSPSC Code:
23151806
eCl@ss:
32031690
NACRES:
NB.24

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

Product Name

Opticap® XL 300 Capsule Media: Millipore Express SPG 0.2 µm, Chemistry: Hydrophobic Polyethersulfone (PES) Inlet: 3/4 in. Sanitary Flange Outlet: 3/4 in. Sanitary Flange

material

polyethersulfone membrane
polyethylene support
polypropylene housing
silicone O-ring

Quality Level

sterility

non-sterile

Sterilization Compatibility

gamma compatible
x-ray compatible

product line

Opticap® XL

feature

hydrophobic

manufacturer/tradename

Opticap®

parameter

2.1 bar max. differential pressure (30 psid) at 4-40 °C (Reverse)
60 psid max. differential pressure (4.1 bar) at 4-40 °C (Forward)

technique(s)

gas filtration: suitable

filtration area

0.048 m2

impurities

<0.25  EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

gravimetric extractables

≤3 mg

matrix

Millipore Express® SPG

pore size

0.2 μm pore size

bubble point

≥1210 mbar (17.5 psig), air with 70/30% IPA/water at 23 °C

fitting

19 mm (3/4 in.) inlet sanitary flange
19 mm (3/4 in.) outlet sanitary flange

shipped in

ambient

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
KEGBG003HH3KEGBG050HHKHGEG003FF3
pore size

0.2 μm pore size

pore size

0.2 μm pore size

pore size

0.2 μm pore size

pore size

-

filtration area

0.048 m2

filtration area

0.048 m2

filtration area

19.6 cm2

filtration area

290 cm2

product line

Opticap® XL 300

product line

Opticap® XL 300

product line

-

product line

Opticap® XL 3

technique(s)

gas filtration: suitable

technique(s)

gas filtration: suitable

technique(s)

gas filtration: suitable

technique(s)

sterile filtration: suitable

matrix

Millipore Express® SPG

matrix

Millipore Express® SPG

matrix

Millipore Express® SPG

matrix

Millipore Express® SHC

material

polyethersulfone membrane, polypropylene (gamma-stable), polypropylene vent cap, silicone seal, polyethylene support, polysulfone , polypropylene housing

material

polyethersulfone membrane, polyethylene support, polypropylene (gamma-stable), polypropylene housing, polypropylene vent cap, polysulfone , silicone seal

material

PBT-based blend (gamma-stable), polyethersulfone membrane

material

polyethersulfone , polyethylene support, polypropylene (gamma-stable), polypropylene housing, polypropylene vent cap (Gamma stable), polysulfone , silicone seal

General description

Device Configuration: Capsule

Packaging

Double Easy-Open bag

Preparation Note

Sterilization Method
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
This product was manufactured with a Millipore Express membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Analysis Note

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Gravimetric Extractables: after 24 hours in a 70/30% IPA/water mixture at controlled room temperature
HydroCorr: ≤0.16 mL/min @ 2.6 bar (38 psig)
TOC/Conductivity
After gamma irradiation and three autoclave cycles, the TOC was measured to be equal to or less than 3367 µg/device.

Other Notes

Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
Express is a trademark of Merck KGaA, Darmstadt, Germany
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Questions

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service