Skip to Content
Merck

900667

Acetonitrile

≥99.92%, suitable for mass spectrometry (MS), UHPLC

Synonym(s):

ACN, Cyanomethane, Ethyl nitrile, Methyl cyanide

Sign In to View Organizational & Contract Pricing

Select a Size

100 ML

¥23,600

250 ML

¥25,400

1 L

¥76,600

4 X 4 L

¥545,000

¥23,600


Check Cart for Availability

Request a Bulk Order

About This Item

Linear Formula:
CH3CN
CAS Number:
Molecular Weight:
41.05
Beilstein:
741857
EC Number:
MDL number:
UNSPSC Code:
12191502
NACRES:
NA.21
Grade:
HPLC grade
Assay:
≥99.92%
Technique(s):
mass spectrometry (MS): suitable
Application(s):
PFAS testing
food and beverages
Bp:
81-82 °C (lit.)
Vapor pressure:
72.8 mmHg ( 20 °C)

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

Product Name

Acetonitrile, for UHPLC, suitable for mass spectrometry (MS)

grade

HPLC grade

Quality Level

Agency

suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 1633
suitable for EPA 8327
suitable for GB 31604.35-2016
suitable for GB 5009.253-2016
suitable for ISO 21675 2019

reg. compliance

suitable for FDA C-010.02

vapor density

1.41 (vs air)

vapor pressure

72.8 mmHg ( 20 °C)

Assay

≥99.92%

form

liquid

autoignition temp.

973 °F

expl. lim.

16 %

technique(s)

mass spectrometry (MS): suitable

refractive index

n20/D 1.344 (lit.)

bp

81-82 °C (lit.)

mp

−45 °C (lit.)

density

0.786 g/mL at 25 °C (lit.)

SMILES string

CC#N

application(s)

PFAS testing
food and beverages

format

neat

InChI

1S/C2H3N/c1-2-3/h1H3

InChI key

WEVYAHXRMPXWCK-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
4391341.1335834881
assay

≥99.92%

assay

≥99.9%

assay

≥99.8% (GC)

assay

≥99.8% (GC)

application(s)

food and beverages

application(s)

food and beverages

application(s)

food and beverages
pharmaceutical

application(s)

food and beverages

Quality Level

100

Quality Level

100

Quality Level

200

Quality Level

100

technique(s)

mass spectrometry (MS): suitable

technique(s)

HPLC: suitable, UV/Vis spectroscopy: suitable

technique(s)

-

technique(s)

HPLC-GC: suitable, HPLC: suitable, gas chromatography (GC): suitable

form

liquid

form

liquid

form

liquid

form

liquid

vapor pressure

72.8 mmHg ( 20 °C)

vapor pressure

72.8 mmHg ( 20 °C)

vapor pressure

72.8 mmHg ( 20 °C), 97 hPa ( 20 °C)

vapor pressure

72.8 mmHg ( 20 °C)

General description

Acetonitrile, an aliphatic nitrile, is a highly volatile, aprotic polar organic solvent that finds wide use in analytical determinations. It is UV-transparent − a property that facilitates its utilization in spectrophotometric and fluorimetric analyses. Its low viscosity, high elution strength and miscibility in water makes it viable in many chromatography systems.
Its other applications include its use as a mobile phase additive and as an extraction solvent in liquid-liquid extraction (LLC), solid-phase extraction (SPE) and microextraction for chromatographic applications, etc.[1]

Application

Acetonitrile may be used:
  • As an extraction solvent for the quantification of pesticide analytes in foodstuffs[2][3] and tea,[4] industrial dyes in juice and wine[5] by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).
  • As an organic modifier in the determination of bisphenol A-diglycidyl ether, bisphenol F-diglycidyl ether and their derivatives in canned food and beverages by fast LC–MS/MS.[6]

Acetonitrile, an organic solvent, is used as a mobile phase/extraction solvent in the ultra-high performance liquid chromatorgraphy − tandem mass spectrometry (UHPLC-MS) analysis of pesticides in tobacco samples.[7] It can be potentially used with a reverse-phase column to determine the concentration of diclofenac (DCF).[8]

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials

Pictograms

FlameExclamation mark

Signal Word

Danger

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point(F)

35.6 °F - closed cup

Flash Point(C)

2.0 °C - closed cup


Regulatory Listings

Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.

PDSCL

Deleterious substance

FSL

Group 4: Flammable liquids
Type 1 petroleums
Hazardous rank II
Water soluble liquid

ISHL Indicated Name

Substances Subject to be Indicated Names

ISHL Notified Names

Substances Subject to be Notified Names

JAN Code

900667-VAR:
900667-250ML:4548174010105
900667-BULK:
900667-4X4L:4548174010112
900667-1L:4548174010099
900667-100ML:4548174010082


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Rapid determination of organonitrogen, organophosphorus and carbamate pesticides in tea by ultrahigh-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS)
Zhao HX, et al.
Food Analytical Methods, 6(2), 497-505 (2013)
Determination of 27 industrial dyes in juice and wine using ultra performance liquid chromatography with electrospray ionization tandem quadrupole mass spectrometry
Zhao S, et al.
Se Pu / Chinese Journal of Chromatography, 28(4), 356-362 (2010)
Barbara Giroud et al.
Journal of chromatography. A, 1316, 53-61 (2013-10-15)
Beebread is among the matrices suspected of contaminating honeybee. To better understand this contamination, the study aimed to develop an efficient, sensitive and reliable analytical method for the trace analysis of pesticides in beebread. This study focuses specifically on the
Gabrieli Bernardi et al.
Talanta, 161, 40-47 (2016-10-23)
An effective method has been developed and validated for the determination of residues of 55 pesticides in tobacco. The proposed sample preparation method is based on acetonitrile extraction, low-temperature precipitation (LTP) and dispersive solid phase extraction (d-SPE) clean-up. Gas chromatography
Roberto Nisticò et al.
Nanomaterials (Basel, Switzerland), 9(8) (2019-08-02)
The photodegradation of an aqueous solution of diclofenac (DCF) has been attempted in the presence of hydrogen peroxide and organic/inorganic hybrid magnetic materials under simulated and real solar light. The hybrid magnetic materials have been prepared via coprecipitation synthesis starting

Articles

LC-UV-MS workflow details teriparatide peptide mapping, including enzymatic digestion, separation conditions, and QTOF mass spectrometer identification.

Learn about UHPLC-MS analysis of trastuzumab on a BIOshell™ 160A peptide C18 column and discover reduced solvent consumption in peptide mapping using 1.5 mm I.D. columns.

Chromolith® RP-18e columns optimize Oligo Standard 6 separation with varied flow rates and ion-pairing reagent evaluation.

Learn more about our Kava CRM solution for use in quantitative and qualitative analysis of kavalactones and flavokavains in kava products to confirm their potency and authenticity.

Protocols

Chromatographic technique identifies insulin variants efficiently, aiding in pharmacokinetics.

Related Content

FAS、すなわち「永遠の化学物質」は環境中に残留し続け、ヒトの健康にリスクをもたらします。PFAS分析に携わる研究者、規制当局、PFAS定量用のメルクの環境モニタリングツールをご覧ください。

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service